Cited by 98Cardiac electrophysiology and arrhythmiasECG Monitoring and AnalysisCardiac pacing and defibrillation studies

Comparison of QT Interval Readings in Normal Sinus Rhythm Between a Smartphone Heart Monitor and a 12‐Lead ECG for Healthy Volunteers and Inpatients Receiving Sotalol or Dofetilide

GARABELLI, PAUL, STAVRAKIS, STAVROS, ALBERT, MICHAEL, KOOMSON, EDWARD, PARWANI, PURVI, CHOHAN, JAWAD, SMITH, LANDGRAVE, ALBERT, DAVID +4 more·2016·Journal of Cardiovascular Electrophysiology

Abstract

QT Interval Readings With a Smartphone Heart Monitor: Introduction: A variety of medications ranging from antiarrhythmics to psychotropics, as well as conditions such as bradycardia, can prolong the QT interval, increasing the risk for life‐threatening arrhythmias. Monitoring the corrected QT interval (QTc) is therefore critical for patient safety. The recent development of smart phone heart monitors (SHM) may allow for easier QTc monitoring. We sought to evaluate the accuracy of an SHM for assessing the QTc, as compared to the standard 12‐lead ECG. Methods and Results: We compared the QTc interval in lead‐I and lead‐II between an SHM and 12‐lead ECG. Healthy volunteers and hospitalized patients in sinus rhythm being loaded on dofetilide or sotalol were included. Manual and automatic measurements were studied. Across 99 healthy volunteers, the SHM QTc demonstrated good agreement (bias = 4 milliseconds, standard deviation of bias = 11 milliseconds) compared to the 12‐lead ECG, using the Bland–Altman method of agreement. Across all hospitalized patients, the SHM was capable of demonstrating QTc prolongation. Between the 12‐lead ECG and SHM, lead‐I measurements had reasonable agreement (bias = 3 milliseconds, standard deviation of bias = 46 milliseconds). A QTc of > 500 milliseconds was associated with a higher likelihood (OR = 12.0; 95% CI 1.5–111.4; P = 0.02) to not achieve perfect agreement. Conclusion: The SHM is accurate in measuring QTc interval in sinus rhythm when compared to 12‐lead ECG in healthy volunteers. For patients receiving QT prolonging antiarrhythmics, SHM is capable of detecting QTc prolongation, and lead‐I of the SHM is most accurate in measuring the QTc if < 500 milliseconds.

Integrity signals

Registry

Crossref · 10.1111/jce.12976

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
GARABELLI, P., STAVRAKIS, S., ALBERT, M., KOOMSON, E., PARWANI, P., CHOHAN, J., SMITH, L., ALBERT, D., XIE, R., XIE, Q., REYNOLDS, D., & PO, S.
Affiliations
  • University of Oklahoma Health Sciences Center (US)
  • AliveCor Oklahoma City Oklahoma USA
Corresponding author
GARABELLI, PAUL
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2016-04-29
Volume
27
Issue
7
Pages
827-832
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2316598919
Cited by
98
References
24
Citations by year
2025: 5 · 2024: 8 · 2023: 9 · 2022: 5 · 2021: 28 · 2020: 24 · 2019: 8 · 2018: 7 · 2017: 2 · 2016: 2
FWCI
5.22
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Cardiovascular Electrophysiology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
Keywords
QTc interval, QTc prolongation, 12-lead ECG, sotalol, dofetilide, QT prolongation, antiarrhythmic drugs, arrhythmia risk, measurement agreement, lead I, hospitalized patients, healthy volunteers
MeSH terms
Smartphone, Action Potentials, Aged, Anti-Arrhythmia Agents, Arrhythmias, Cardiac, Electrocardiography, Female, Heart Rate, Humans, Inpatients, Male, Middle Aged, Phenethylamines, Predictive Value of Tests, Sotalol, Sulfonamides, Reproducibility of Results, Case-Control Studies, Mobile Applications, Healthy Volunteers

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review