Performance of an Implantable Cardiac Monitor to Detect Atrial Fibrillation: Results of the DETECT AF Study
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
DETECT AF Study Results: Introduction: Reliable detection and monitoring of atrial fibrillation (AF) is essential for accurate clinical decision making, which can now be done continuously with the introduction of implantable cardiac monitors (ICM) The DETECT AF study evaluated the performance of the Confirm DM2102 ICM (St. Jude Medical, St. Paul, MN, USA) to accurately detect and monitor AF. Methods: Ninety patients previously implanted with the ICM and with either suspected or known paroxysmal AF were enrolled at 12 centers in Germany and The Netherlands. At least 2 weeks after ICM implant, patients wore a Holter monitor for 4 days, while the ICM monitored for AF episodes lasting at least 2 minutes. Holter monitor data was analyzed by a blinded, independent core laboratory and compared to the ICM AF detections. Patient and episode sensitivity (SE), specificity (SP), positive predictive value (PPV), and negative predictive (NPV) were calculated using standard analysis and a generalized estimation equation method where appropriate. Results: A total of 79/90 subjects (61% male, 65.7 ± 9.6 years old) were included in the analysis, totaling 6,894 hours of Holter monitoring. Using a per patient analysis SE was 100%, PPV was 64.0%, SP was 85.7%, and NPV was 100%. Using a per episode analysis, SE was 94.0% and PPV was 64.0%. With an AF duration analysis, the SE was 83.9%, PPV was 97.3%, SP was 99.4% with an NPV of 98.5%. Conclusion: The SJM Confirm DM2102 can accurately and repeatedly detect paroxysmal AF episodes of at least 2 minutes in length.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
2014 AHA/ACC/HRS Guideline for the Management of Patients With Atrial Fibrillation
January, C. T., Wann, L. S., Alpert, J. S., Calkins, H., Cigarroa, J. E., Cleveland, J. C., Conti, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.03.022 · Cited by 2,955
Cryptogenic stroke and underlying atrial fibrillation
Sanna, T., Diener, H.-C., Passman, R. S., Di Lazzaro, V., Bernstein, R. A., Morillo, C. A., Rymer, M. M., Thijs, V., Rogers, T., Beckers, F., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1313600 · Cited by 2,161
Self-citationSubclinical atrial fibrillation and the risk of stroke
Healey, J. S., Connolly, S. J., Gold, M. R., Israel, C. W., Van Gelder, I. C., Capucci, A., Lau, C. P., Fain, E., Yang, S., Bailleul, C., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1105575 · Cited by 2,100
Glotzer, T. V., Hellkamp, A. S., Zimmerman, J., Sweeney, M. O., Yee, R., Marinchak, R., Cook, J., Paraschos, A., Love, J., Radoslovich, G., et al. (2003) · Circulation · doi:10.1161/01.cir.0000057981.70380.45 · Cited by 750
Indications for the use of diagnostic implantable and external ECG loop recorders
Task Force members, Brignole, M., Vardas, P., Hoffman, E., Huikuri, H., Moya, A., Ricci, R., Sulke, N., Wieling, W., EHRA Scientific Documents Committee, et al. (2009) · Europace · doi:10.1093/europace/eup097 · Cited by 362
Cited by
Van Gelder, I. C., Rienstra, M., Bunting, K. V., Casado-Arroyo, R., Caso, V., Crijns, H. J. G. M., De Potter, T. J. R., Dwight, J., Guasti, L., Hanke, T., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae176 · Cited by 3,024
Self-citationSmartwatch Performance for the Detection and Quantification of Atrial Fibrillation
Wasserlauf, J., You, C., Patel, R., Valys, A., Albert, D., & Passman, R. (2019) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.118.006834 · Cited by 245
Varma, N., Cygankiewicz, I., Turakhia, M. P., Heidbuchel, H., Hu, Y.-F., Chen, L. Y., Couderc, J.-P., Cronin, E. M., Estep, J. D., Grieten, L., et al. (2021) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.120.009204 · Cited by 74
Newer technologies for detection of atrial fibrillation
Zungsontiporn, N., & Link, M. S. (2018) · BMJ · doi:10.1136/bmj.k3946 · Cited by 53
Veltmann, C., Bosch, R., Boer, J., Endres, M., Frankenstein, L., Gröschel, K., Hansen, C., & Straube, F. (2023) · Die Kardiologie · doi:10.1007/s12181-023-00634-z · Cited by 3
Metadata
- Authors
- NÖLKER, G., MAYER, J., BOLDT, L., SEIDL, K., VAN DRIEL, V., MASSA, T., KOLLUM, M., BRACHMANN, J., DENEKE, T., HINDRICKS, G., JUNG, W., BRUNNER, K. J., KRAUS, S., HÜMMER, A., & LEWALTER, T.
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2016-10-07
- Volume
- 27
- Issue
- 12
- Pages
- 1403-1410
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W2517108456
- Cited by
- 69
- References
- 5
- FWCI
- 4.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.