A method to screen left ventricular dysfunction through ECG based on convolutional neural network
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Objective: This study aims to develop an artificial intelligence‐based method to screen patients with left ventricular ejection fraction (LVEF) of 50% or lesser using electrocardiogram (ECG) data alone. Methods: Convolutional neural network (CNN) is a class of deep neural networks, which has been widely used in medical image recognition. We collected standard 12‐lead ECG and transthoracic echocardiogram (TTE) data including the LVEF value. Then, we paired the ECG and TTE data from the same individual. For multiple ECG‐TTE pairs from a single individual, only the earliest data pair was included. All the ECG‐TTE pairs were randomly divided into the training, validation, or testing data set in a ratio of 9:1:1 to create or evaluate the CNN model. Finally, we assessed the screening performance by overall accuracy, sensitivity, specificity, positive predictive value, and negative predictive value. Results: We retrospectively enrolled a total of 26 786 ECG‐TTE pairs and randomly divided them into training (n = 21 732), validation (n = 2 530), and testing data set (n = 2 530). In the testing set, the CNN algorithm showed an overall accuracy of 73.9%, sensitivity of 69.2%, specificity of 70.5%, positive predictive value of 70.1%, and negative predictive value of 69.9%. Conclusion: Our results demonstrate that a well‐trained CNN algorithm may be used as a low‐cost and noninvasive method to identify patients with left ventricular dysfunction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Priori, S. G., Blomström-Lundqvist, C., Mazzanti, A., Blom, N., Borggrefe, M., Camm, J., Elliott, P. M., Fitzsimons, D., Hatala, R., Hindricks, G., et al. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv316 · Cited by 3,893
Hannun, A. Y., Rajpurkar, P., Haghpanahi, M., Tison, G. H., Bourn, C., Turakhia, M. P., & Ng, A. Y. (2019) · Nature Medicine · doi:10.1038/s41591-018-0268-3 · Cited by 3,148
Groenewegen, A., Rutten, F. H., Mosterd, A., & Hoes, A. W. (2020) · European Journal of Heart Failure · doi:10.1002/ejhf.1858 · Cited by 2,043
Attia, Z. I., Noseworthy, P. A., Lopez-Jimenez, F., Asirvatham, S. J., Deshmukh, A. J., Gersh, B. J., Carter, R. E., Yao, X., Rabinstein, A. A., Erickson, B. J., et al. (2019) · The Lancet · doi:10.1016/s0140-6736(19)31721-0 · Cited by 1,613
Attia, Z. I., Kapa, S., Lopez-Jimenez, F., McKie, P. M., Ladewig, D. J., Satam, G., Pellikka, P. A., Enriquez-Sarano, M., Noseworthy, P. A., Munger, T. M., et al. (2019) · Nature Medicine · doi:10.1038/s41591-018-0240-2 · Cited by 1,389 · cited 3×
“18 The research provided a novel insight into the CNN algorithm, which could recognize subtle alterations associated with LV function in ECGs and permit optimal utilization of existing ECG data.”
BackgroundMethodInfluentialArtificial Intelligence in Health Care: A Report From the National Academy of Medicine
Matheny, M. E., Whicher, D., & Thadaney Israni, S. (2020) · JAMA · doi:10.1001/jama.2019.21579 · Cited by 628
Machine learning in cardiovascular medicine: are we there yet?
Shameer, K., Johnson, K. W., Glicksberg, B. S., Dudley, J. T., & Sengupta, P. P. (2018) · Heart · doi:10.1136/heartjnl-2017-311198 · Cited by 555 · cited 1×
“in the human visual cortex, which could abstract small generic spatial features from the vast amounts of input data.(17) Conventional 12‐lead electrocardiogram (ECG) is a regular”
BackgroundKo, W.-Y., Siontis, K. C., Attia, Z. I., Carter, R. E., Kapa, S., Ommen, S. R., Demuth, S. J., Ackerman, M. J., Gersh, B. J., Arruda-Olson, A. M., et al. (2020) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.12.030 · Cited by 404
Galloway, C. D., Valys, A. V., Shreibati, J. B., Treiman, D. L., Petterson, F. L., Gundotra, V. P., Albert, D. E., Attia, Z. I., Carter, R. E., Asirvatham, S. J., et al. (2019) · JAMA Cardiology · doi:10.1001/jamacardio.2019.0640 · Cited by 318 · cited 2×
“For example, a recent AI model proposed by Galloway et al.(21) was able to screen for hyperkalemia from the electrocardiogram with a sensitivity of 88.”
MethodInfluentialScreening for Asymptomatic Left Ventricular Dysfunction Using B‐Type Natriuretic Peptide
McDonagh, T. A., McDonald, K., & Maisel, A. S. (2008) · Congestive Heart Failure · doi:10.1111/j.1751-7133.2008.tb00002.x · Cited by 35 · cited 2×
“4 – 6 During the early stage of LV dysfunction, patients are usually asymptomatic or only present mild signs and symptoms.”
Background
Cited by
Bjerkén, L. V., Rønborg, S. N., Jensen, M. T., Ørting, S. N., & Nielsen, O. W. (2022) · Heart Failure Reviews · doi:10.1007/s10741-022-10283-1 · Cited by 50
König, S., Hohenstein, S., Nitsche, A., Pellissier, V., Leiner, J., Stellmacher, L., Hindricks, G., & Bollmann, A. (2024) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztad081 · Cited by 21
A comprehensive review of AI-Based detection of Arrhythmia using Electrocardiogram (ECG)
Ayyub, A., Politis, C., & Usman, M. A. (2025) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2025.110594 · Cited by 18
Metadata
- Authors
- Sun, J., Qiu, Y., Guo, H., Hua, Y., Shao, B., Qiao, Y., Guo, J., Ding, H., Zhang, Z., Miao, L., Wang, N., Zhang, Y., Chen, Y., Lu, J., Dai, M., Zhang, C., & Wang, R.
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2021-02-15
- Volume
- 32
- Issue
- 4
- Pages
- 1095-1102
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W3127307335
- Cited by
- 36
- References
- 10
- FWCI
- 3.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A method to screen left ventricular dysfunction through ECG based on convolutional neural network. https://app.cochat.ai/papers/10.1111/jce.14936
- The paper
- Sun, J., Qiu, Y., Guo, H., Hua, Y., Shao, B., Qiao, Y., Guo, J., Ding, H., Zhang, Z., Miao, L., Wang, N., Zhang, Y., Chen, Y., Lu, J., Dai, M., Zhang, C., & Wang, R. (2021). A method to screen left ventricular dysfunction through ECG based on convolutional neural network. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.14936
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.