Eliminating the Human Factor in Office Blood Pressure Measurement
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Factors related to the physician/nurse and patient and their interaction are potential sources of error in manual office blood pressure (MOBP). The use of automated sphygmomanometers to record blood pressure (BP) with the patient alone reduces measurement error and minimizes anxiety‐related increases in BP, thus eliminating the “white‐coat” response. Comparative studies have shown the cut‐point for a normal automated office BP (AOBP), awake ambulatory BP, and home BP (<135/85 mmHg) to be similar, providing the patient does not rest for a prolonged period before the first AOBP reading, as recommended for MOBP measurement. AOBP should now replace MOBP in routine clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mancia, G., Fagard, R., Narkiewicz, K., Redón, J., Zanchetti, A., Böhm, M., Christiaens, T., Cifkova, R., De Backer, G., Dominiczak, A., et al. (2013) · Journal of Hypertension · doi:10.1097/01.hjh.0000431740.32696.cc · Cited by 5,655
Omboni, S., Gazzola, T., Carabelli, G., & Parati, G. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e32835ca8dd · Cited by 313 · cited 1×
“the doctor’s office without any chance of the values being altered.(33) AOBP corrects some of the problems associated with”
BackgroundMeasurement of Blood Pressure in the Office: Recognizing the Problem and Proposing the Solution
Myers, M. G., Godwin, M., Dawes, M., Kiss, A., Tobe, S. W., & Kaczorowski, J. (2010) · Hypertension · doi:10.1161/hypertensionaha.109.141879 · Cited by 260
Self-citation
Cited by
Daskalopoulou, S. S., Rabi, D. M., Zarnke, K. B., Dasgupta, K., Nerenberg, K., Cloutier, L., Gelfer, M., Lamarre-Cliche, M., Milot, A., Bolli, P., et al. (2015) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2015.02.016 · Cited by 684
Leung, A. A., Nerenberg, K., Daskalopoulou, S. S., McBrien, K., Zarnke, K. B., Dasgupta, K., Cloutier, L., Gelfer, M., Lamarre-Cliche, M., Milot, A., et al. (2016) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2016.02.066 · Cited by 461
Roerecke, M., Kaczorowski, J., & Myers, M. G. (2019) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2018.6551 · Cited by 216
Self-citationPadwal, R., Campbell, N. R. C., Schutte, A. E., Olsen, M. H., Delles, C., Etyang, A., Cruickshank, J. K., Stergiou, G., Rakotz, M. K., Wozniak, G., et al. (2019) · Journal of Hypertension · doi:10.1097/hjh.0000000000002112 · Cited by 108
“As mentioned above, AOBP offers the ability to perform three to five unattended, sequential BP measurements and auto-calculate the mean [40].”
BackgroundEgan, B. M., Sutherland, S. E., Rakotz, M., Yang, J., Hanlin, R. B., Davis, R. A., & Wozniak, G. (2018) · Hypertension · doi:10.1161/hypertensionaha.118.11558 · Cited by 104
“A protocol including repeated attended BP when the initial value was high would likely have resulted in a higher percentage of patients with mean BP 140/ 90 mm Hg and reduced the requirement for unattended AOBP.”
BackgroundInfluentialPrevalence of pseudoresistant hypertension due to inaccurate blood pressure measurement
Bhatt, H., Siddiqui, M., Judd, E., Oparil, S., & Calhoun, D. (2016) · Journal of the American Society of Hypertension · doi:10.1016/j.jash.2016.03.186 · Cited by 77
Human Errors in Automated Office Blood Pressure Measurement: Still Room for Improvement
Elias, M. F., & Goodell, A. L. (2021) · Hypertension · doi:10.1161/hypertensionaha.120.16164 · Cited by 31
Metadata
- Authors
- Myers, M. G.
- Venue
- The Journal of Clinical Hypertension
- Publisher
- Wiley
- Published
- 2014-01-04
- Volume
- 16
- Issue
- 2
- Pages
- 83-86
- ISSN
- 1524-6175 (ISSN-L)
- 1751-7176
- OpenAlex
- W2109839047
- Cited by
- 52
- References
- 3
- FWCI
- 6.53
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.