Functional Performance as a Predictor of Injurious Falls in Older Adults
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Objectives: To determine whether a performance battery and its components aid in predicting injurious falls. Design: Longitudinal analysis; prospective cohort study. Setting: Clinical site. Participants: Boston‐area community‐dwelling adults (N = 755; mean age ± SD 78.1 ± 5.4, 64.1% female, 77.6% white). Measurements: Baseline functional performance was determined according to the Short Physical Performance Battery ( SPPB ), measuring balance, gait speed, and five repeated chair stands. Fall history (past year) and efficacy in performing 10 daily activities without falling were assessed. Falls were assessed using a daily calendar over 4 years. Injurious falls were defined as resulting in fractures, sprains, dislocations, pulled or torn muscles, ligaments, or tendons or seeking medical attention. Results: Poorest chair stand performance (≥16.7 seconds) was associated with greater hazard of injurious falls than in all other chair stand performance groups (hazard ratio ( HR ) = 1.96, 95% confidence interval ( CI ) = 1.18–3.26 for ≥ 16.7 vs. 13.7–16.6 seconds; HR = 1.65, 95% CI = 1.07–2.55 for ≥ 16.7 vs. 11.2–13.6 seconds, HR = 1.60, 95% CI = 1.03–2.48 for ≥ 16.7 vs. <11.2 seconds). SPPB did not predict injurious falls. Fall history predicted injurious falls ( HR = 1.82, 95% CI = 1.39–2.39); falls efficacy did not. Fall history and a slow chair stand (<16.7 seconds) had a 2‐year cumulative incidence rate of an injurious fall of 46% (95% CI = 0.34–0.58), nearly the combined rate of a positive fall history (0.29, 95% CI = 0.25–0.34) and a slow chair stand alone (0.21, 95% CI = 0.13–0.30). Conclusion: An easily administered chair stand test may be sufficient for evaluating performance as part of a risk stratification strategy for injurious falls.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kok, J. S., Berg, I. J., & Scherder, E. J. A. (2013) · Dementia and Geriatric Cognitive Disorders Extra · doi:10.1159/000353441 · Cited by 20,589
Guralnik, J. M., Simonsick, E. M., Ferrucci, L., Glynn, R. J., Berkman, L. F., Blazer, D. G., Scherr, P. A., & Wallace, R. B. (1994) · Journal of Gerontology · doi:10.1093/geronj/49.2.m85 · Cited by 9,792
Guralnik, J. M., Ferrucci, L., Pieper, C. F., Leveille, S. G., Markides, K. S., Ostir, G. V., Studenski, S., Berkman, L. F., & Wallace, R. B. (2000) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/55.4.m221 · Cited by 2,898
Self-citationThe Use of Psychological Testing for Treatment Planning and Outcomes Assessment
(2004) · doi:10.4324/9781410610614 · Cited by 1,503
Cited by
Short-Physical Performance Battery (SPPB) score is associated with falls in older outpatients
Lauretani, F., Ticinesi, A., Gionti, L., Prati, B., Nouvenne, A., Tana, C., Meschi, T., & Maggio, M. (2019) · Aging Clinical and Experimental Research · doi:10.1007/s40520-018-1082-y · Cited by 211
Parry, S. W., Bamford, C., Deary, V., Finch, T. L., Gray, J., MacDonald, C., McMeekin, P., Sabin, N. J., Steen, I. N., Whitney, S. L., et al. (2016) · Health Technology Assessment · doi:10.3310/hta20560 · Cited by 167
“Functional decline and fatigue are related to SPPB scores, yet injurious falls were not related to total SPPB scores.(76) Injurious falls were related to taking ≥ 16.”
BackgroundStrotmeyer, E. S., Winger, M. E., Cauley, J. A., Boudreau, R. M., Cusick, D., Collins, R. F., Chalhoub, D., Buehring, B., Orwoll, E., Harris, T. B., et al. (2018) · The Journal of nutrition, health and aging · doi:10.1007/s12603-018-1081-x · Cited by 32
“Since older adults with poor function are at higher risk of disability, falls and fall injuries (15-18), “functional power” may be a more appropriate muscle function predictor.”
Morrison, R. T., Taylor, S., Buckley, J., Twist, C., & Kite, C. (2023) · Journal of Physiotherapy · doi:10.1016/j.jphys.2023.05.018 · Cited by 11
“Age-related functional decline is characterised by a loss of independence in completing activities of daily living,(2) which has a detrimental impact on quality of life,(3) mortality(4) and the incidence of injurious falls.(5) Because functional decline falls under the physical domain of frailty syndrome,(6) functiona…”
Background
Metadata
- Authors
- Ward, R. E., Leveille, S. G., Beauchamp, M. K., Travison, T., Alexander, N., Jette, A. M., & Bean, J. F.
- Venue
- Journal of the American Geriatrics Society
- Publisher
- Wiley
- Published
- 2015-02
- Volume
- 63
- Issue
- 2
- Pages
- 315-320
- ISSN
- 0002-8614 (ISSN-L)
- 1532-5415
- OpenAlex
- W2060273479
- Cited by
- 147
- References
- 4
- FWCI
- 45.61
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.