Cited by 212Advanced X-ray Imaging TechniquesAdvanced X-ray and CT ImagingComparative Animal Anatomy Studies

An exploratory study of contrast agents for soft tissue visualization by means of high resolution X‐ray computed tomography imaging

PAUWELS, E., VAN LOO, D., CORNILLIE, P., BRABANT, L., VAN HOOREBEKE, L.·2013·Journal of Microscopy

Abstract

Summary: High resolution X‐ray computed tomography (CT), or microCT, is a promising and already widely used technique in various scientific fields. Also for histological purposes it has great potential. Although microCT has proven to be a valuable technique for the imaging of bone structures, the visualization of soft tissue structures is still an important challenge due to their low inherent X‐ray contrast. One way to achieve contrast enhancement is to make use of contrast agents. However, contrary to light and electron microscopy, knowledge about contrast agents and staining procedures is limited for X‐ray CT. The purpose of this paper is to identify useful X‐ray contrast agents for soft tissue visualization, which can be applied in a simple way and are also suited for samples larger than (1 cm) 3 . And 28 chemical substances have been investigated. All chemicals were applied in the form of concentrated aqueous solutions in which the samples were immersed. First, strips of green Bacon were stained to evaluate contrast enhancement between muscle and adipose tissue. Furthermore it was also tested whether the contrast agents remained fixed in the tissue after staining by re‐immersing them in water. Based on the results, 12 contrast agents were selected for further testing on postmortem mice hind legs, containing a variety of different tissues, including muscle, fat, bone, cartilage and tendons. It was evaluated whether the contrast agents allowed a clearer distinction between the different soft tissue structures present. Finally also penetration depth was measured. And 26 chemicals resulted in contrast enhancement between muscle and adipose tissue in the Bacon strips. Mercury(II)chloride (HgCl 2 ), phosphotungstic acid (PTA), phosphomolybdic acid (PMA) and ammonium orthomolybdate ((NH 4 ) 2 MoO 4 ) remained fixed after re‐immersion in water. The penetration tests showed that potassium iodide (KI) and sodium tungstate can be most efficiently used for large samples of the order of several tens of cm 3 . PMA, PTA, HgCl 2 and also to a lesser extent Na 2 WO 4 and (NH 4 ) 2 MoO 4 allowed a clearer distinction between the different soft tissue structures present.

Integrity signals

Registry

Crossref · 10.1111/jmi.12013

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • To image insects with conventional micro-CT, staining and/or drying is often required to discriminate between tissues.

    “to image insects with conventional micro-CT, staining and/or drying is often required to discriminate between tissues 16 – 19”

    From High-throughput phenomics of global ant biodiversity (2026) · cites this paper as [19]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
PAUWELS, E., VAN LOO, D., CORNILLIE, P., BRABANT, L., & VAN HOOREBEKE, L.
Affiliations
Ghent University (BE)
Corresponding author
PAUWELS, E.
Venue
Journal of Microscopy
Publisher
Wiley
Published
2013-02-22
Volume
250
Issue
1
Pages
21-31
ISSN
  • 0022-2720 (ISSN-L)
  • 1365-2818
OpenAlex
W1833649979
Cited by
212
References
38
Citations by year
2026: 14 · 2025: 12 · 2024: 15 · 2023: 13 · 2022: 17 · 2021: 14 · 2020: 23 · 2019: 28 · 2018: 24 · 2017: 20 · 2016: 10 · 2015: 8 · 2014: 9 · 2013: 4 · 2012: 1
FWCI
10.23
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Microscopy (publishedVersion)
  • PubMed (publishedVersion)
  • Ghent University Academic Bibliography (Ghent University) (submittedVersion)
Topics
  • Physical Sciences › Physics and Astronomy › Radiation › Advanced X-ray Imaging Techniques
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced X-ray and CT Imaging
  • Health Sciences › Medicine › Urology › Comparative Animal Anatomy Studies
Keywords
X-ray contrast agents, soft tissue visualization, micro-CT, contrast enhancement, tissue staining, mercuric chloride, phosphotungstic acid, phosphomolybdic acid, sodium tungstate, potassium iodide, penetration depth, tissue fixation
MeSH terms
Animals, Contrast Media, Image Processing, Computer-Assisted, Staining and Labeling, Swine, Lower Extremity, Mice, X-Ray Microtomography

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review