CoChat

Reliability and concurrent validity of a new iP hone® goniometric application for measuring active wrist range of motion: a cross‐sectional study in asymptomatic subjects

Open access
Pourahmadi, Mohammad Reza, Ebrahimi Takamjani, Ismail, Sarrafzadeh, Javad, Bahramian, Mehrdad, Mohseni‐Bandpei, Mohammad Ali, Rajabzadeh, Fatemeh, Taghipour, Morteza · 2017 · Journal of Anatomy
Cited by 61

The DOI matches its Crossref record.

Abstract

Measurement of wrist range of motion (ROM) is often considered to be an essential component of wrist physical examination. The measurement can be carried out through various instruments such as goniometers and inclinometers. Recent smartphones have been equipped with accelerometers and magnetometers, which, through specific software applications (apps) can be used for goniometric functions. This study, for the first time, aimed to evaluate the reliability and concurrent validity of a new smartphone goniometric app (Goniometer Pro©) for measuring active wrist ROM. In all, 120 wrists of 70 asymptomatic adults (38 men and 32 women; aged 18–40 years) were assessed in a physiotherapy clinic located at the School of Rehabilitation Sciences, Iran University of Medical Science and Health Services, Tehran, Iran. Following the recruitment process, active wrist ROM was measured using a universal goniometer and iP hone® 5 app. Two blinded examiners each utilized the universal goniometer and iP hone® to measure active wrist ROM using a volar/dorsal alignment technique in the following sequences: flexion, extension, radial deviation, and ulnar deviation. The second (2 h later) and third (48 h later) sessions were carried out in the same manner as the first session. All the measurements were conducted three times and the mean value of three repetitions for each measurement was used for analysis. Intraclass correlation coefficient (ICC) models (3, k) and (2, k) were used to determine the intra‐rater and inter‐rater reliability, respectively. The Pearson correlation coefficients were used to establish concurrent validity of the iP hone® app. Good to excellent intra‐rater and inter‐rater reliability was demonstrated for the goniometer with ICC values of ≥ 0.82 and ≥ 0.73 and the iP hone® app with ICC values of ≥ 0.83 and ≥ 0.79, respectively. Minimum detectable change at the 95% confidence level (MDC95) was computed as 1.96 × standard error of measurement × √2. The MDC95 ranged from 1.66° to 5.35° for the intra‐rater analysis and from 1.97° to 6.15° for the inter‐rater analysis. The concurrent validity between the two instruments was high, with r values of ≥ 0.80. From the results of this cross‐sectional study, it can be concluded that the iP hone® app possesses good to excellent intra‐rater and inter‐rater reliability and concurrent validity. It seems that this app can be used for the measurement of wrist ROM. However, further research is needed to evaluate symptomatic subjects using this app.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/joa.12568

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Pourahmadi, M. R., Ebrahimi Takamjani, I., Sarrafzadeh, J., Bahramian, M., Mohseni‐Bandpei, M. A., Rajabzadeh, F., & Taghipour, M.
Venue
Journal of Anatomy
Publisher
Wiley
Published
2016-12-02
Volume
230
Issue
3
Pages
484-495
ISSN
  • 0021-8782 (ISSN-L)
  • 1469-7580
OpenAlex
W2557840677
Cited by
61
References
0
FWCI
6.97
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.