Applications of Ultrasound in the Resection of Brain Tumors
Open accessThe DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.
Abstract
Neurosurgery makes use of preoperative imaging to visualize pathology, inform surgical planning, and evaluate the safety of selected approaches. The utility of preoperative imaging for neuronavigation, however, is diminished by the well‐characterized phenomenon of brain shift, in which the brain deforms intraoperatively as a result of craniotomy, swelling, gravity, tumor resection, cerebrospinal fluid (CSF) drainage, and many other factors. As such, there is a need for updated intraoperative information that accurately reflects intraoperative conditions. Since 1982, intraoperative ultrasound has allowed neurosurgeons to craft and update operative plans without ionizing radiation exposure or major workflow interruption. Continued evolution of ultrasound technology since its introduction has resulted in superior imaging quality, smaller probes, and more seamless integration with neuronavigation systems. Furthermore, the introduction of related imaging modalities, such as 3‐dimensional ultrasound, contrast‐enhanced ultrasound, high‐frequency ultrasound, and ultrasound elastography, has dramatically expanded the options available to the neurosurgeon intraoperatively. In the context of these advances, we review the current state, potential, and challenges of intraoperative ultrasound for brain tumor resection. We begin by evaluating these ultrasound technologies and their relative advantages and disadvantages. We then review three specific applications of these ultrasound technologies to brain tumor resection: (1) intraoperative navigation, (2) assessment of extent of resection, and (3) brain shift monitoring and compensation. We conclude by identifying opportunities for future directions in the development of ultrasound technologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Elastography: A quantitative method for imaging the elasticity of biological tissues
Ophir, J. (1991) · Ultrasonic Imaging · doi:10.1016/0161-7346(91)90079-w · Cited by 3,776
An extent of resection threshold for newly diagnosed glioblastomas: Clinical article
Sanai, N., Polley, M.-Y., McDermott, M. W., Parsa, A. T., & Berger, M. S. (2011) · Journal of Neurosurgery · doi:10.3171/2011.2.jns10998 · Cited by 1,646
Role of extent of resection in the long-term outcome of low-grade hemispheric gliomas
Smith, J. S., Chang, E. F., Lamborn, K. R., Chang, S. M., Prados, M. D., Cha, S., Tihan, T., VandenBerg, S., McDermott, M. W., & Berger, M. S. (2008) · Journal of Clinical Oncology · doi:10.1200/jco.2007.13.9337 · Cited by 1,283
Stummer, W., Reulen, H.-J., Meinel, T., Pichlmeier, U., Schumacher, W., Tonn, J.-C., Rohde, V., Oppel, F., Turowski, B., Woiciechowsky, C., et al. (2008) · Neurosurgery · doi:10.1227/01.neu.0000317304.31579.17 · Cited by 1,035
Claudon, M., Dietrich, C. F., Choi, B. I., Cosgrove, D. O., Kudo, M., Nolsøe, C. P., Piscaglia, F., Wilson, S. R., Barr, R. G., Chammas, M. C., et al. (2013) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2012.09.002 · Cited by 971
Power Doppler US: a potentially useful alternative to mean frequency-based color Doppler US.
Rubin, J. M., Bude, R. O., Carson, P. L., Bree, R. L., & Adler, R. S. (1994) · Radiology · doi:10.1148/radiology.190.3.8115639 · Cited by 867
Barr, R. G., Ferraioli, G., Palmeri, M. L., Goodman, Z. D., Garcia-Tsao, G., Rubin, J., Garra, B., Myers, R. P., Wilson, S. R., Rubens, D., et al. (2015) · Radiology · doi:10.1148/radiol.2015150619 · Cited by 632
Claudon, M., Dietrich, C., Choi, B., Cosgrove, D., Kudo, M., Nolsøe, C., Piscaglia, F., Wilson, S., Barr, R., Chammas, M., et al. (2012) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0032-1325499 · Cited by 550
High-speed ultrasound volumetric imaging system. I. Transducer design and beam steering
Smith, S. W., Pavy, H. G., & von Ramm, O. T. (1991) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.68466 · Cited by 504
Impact of extent of resection for recurrent glioblastoma on overall survival: Clinical article
Bloch, O., Han, S. J., Cha, S., Sun, M. Z., Aghi, M. K., McDermott, M. W., Berger, M. S., & Parsa, A. T. (2012) · Journal of Neurosurgery · doi:10.3171/2012.9.jns12504 · Cited by 432
PLUS: Open-Source Toolkit for Ultrasound-Guided Intervention Systems
Lassó, A., Heffter, T., Rankin, A., Pintér, C., Ungi, T., & Gabor Fichtinger, A. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2322864 · Cited by 421
High-speed ultrasound volumetric imaging system. II. Parallel processing and image display
von Ramm, O. T., Smith, S. W., & Pavy, H. G. (1991) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.68467 · Cited by 396
Orringer, D., Lau, D., Khatri, S., Zamora-Berridi, G. J., Zhang, K., Wu, C., Chaudhary, N., & Sagher, O. (2012) · Journal of Neurosurgery · doi:10.3171/2012.8.jns12234 · Cited by 317
Roche, A., Pennec, X., Malandain, G., & Ayache, N. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.959301 · Cited by 289
Intra-operative 3D ultrasound in neurosurgery
Unsgaard, G., Rygh, O. M., Selbekk, T., Müller, T. B., Kolstad, F., Lindseth, F., & Hernes, T. A. N. (2006) · Acta Neurochirurgica · doi:10.1007/s00701-005-0688-y · Cited by 252
Hammoud, M. A., Ligon, B. L., Elsouki, R., Shi, W. M., Schomer, D. F., & Sawaya, R. (1996) · Journal of Neurosurgery · doi:10.3171/jns.1996.84.5.0737 · Cited by 245
SonoWand, an Ultrasound-based Neuronavigation System
Grønningsaeter, A., Kleven, A., Ommedal, S., Aarseth, T. E., Lie, T., Lindseth, F., Langø, T., & Unsgård, G. (2000) · Neurosurgery · doi:10.1093/neurosurgery/47.6.1373 · Cited by 213
Intraoperative Contrast-Enhanced Ultrasound for Brain Tumor Surgery
Prada, F. U., Perin, A., Martegani, A., Aiani, L., Solbiati, L., Lamperti, M., Casali, C., Legnani, F. G., Mattei, L., Saladino, A., et al. (2014) · Neurosurgery · doi:10.1227/neu.0000000000000301 · Cited by 204
Selbekk, T., Jakola, A. S., Solheim, O. S., Johansen, T. F., Lindseth, F., Reinertsen, I., & Unsgård, G. (2013) · Acta Neurochirurgica · doi:10.1007/s00701-013-1647-7 · Cited by 169
Rasmussen, I.-A., Lindseth, F., Rygh, O. M., Berntsen, E. M., Selbekk, T., Xu, J., Nagelhus Hernes, T. A., Harg, E., Håberg, A., & Unsgaard, G. (2007) · Acta Neurochirurgica · doi:10.1007/s00701-006-1110-0 · Cited by 163
Solheim, O. S., Selbekk, T., Jakola, A. S., & Unsgård, G. (2010) · Acta Neurochirurgica · doi:10.1007/s00701-010-0731-5 · Cited by 148
Prada, F. U., Bene, M. D., Fornaro, R., Vetrano, I. G., Martegani, A., Aiani, L., Sconfienza, L. M., Mauri, G., Solbiati, L., Pollo, B., et al. (2016) · Neurosurgical FOCUS · doi:10.3171/2015.11.focus15573 · Cited by 138
The Utility of Transrectal Real-Time Elastography in the Diagnosis of Prostate Cancer
Kamoi, K., Okihara, K., Ochiai, A., Ukimura, O., Mizutani, Y., Kawauchi, A., & Miki, T. (2008) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2007.12.002 · Cited by 126
Sources and impact of artifacts on clinical three‐dimensional ultrasound imaging
Nelson, T. R., Pretorius, D. H., Hull, A., Riccabona, M., Sklansky, M., & James, G. (2000) · Ultrasound in Obstetrics and Gynecology · doi:10.1046/j.1469-0705.2000.00180.x · Cited by 113
Woydt, M., Krone, A., Becker, G., Schmidt, K., Roggendorf, W., & Roosen, K. (1996) · Acta Neurochirurgica · doi:10.1007/bf01411117 · Cited by 109
LeRoux, P. D., Winter, T. C., Berger, M. S., Mack, L. A., Wang, K., & Elliott, J. P. (1994) · Journal of Clinical Ultrasound · doi:10.1002/jcu.1870220107 · Cited by 103
Intraoperative Cerebral Glioma Characterization with Contrast Enhanced Ultrasound
Prada, F. U., Mattei, L., Bene, M. D., Aiani, L., Saini, M., Casali, C., Filippini, A., Legnani, F. G., Perin, A., Saladino, A., et al. (2014) · BioMed Research International · doi:10.1155/2014/484261 · Cited by 102
Watson, J. C., Shawker, T. H., Nieman, L. K., DeVroom, H. L., Doppman, J. L., & Oldfield, E. H. (1998) · Journal of neurosurgery · doi:10.3171/jns.1998.89.6.0927 · Cited by 100
Decontamination of minimally invasive surgical endoscopes and accessories
Ayliffe, G. A. J. (2000) · Journal of Hospital Infection · doi:10.1053/jhin.2000.0767 · Cited by 94
Pan, H., Wu, N., Ding, H., Ding, Q., Dai, J., Ling, L., Chen, L., Zha, X., Liu, X., Zhou, W., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0074028 · Cited by 81
Global Registration of Ultrasound to MRI Using the LC2 Metric for Enabling Neurosurgical Guidance
Wein, W., Ladikos, A., Fuerst, B., Shah, A. M., Sharma, K., & Navab, N. (2013) · Lecture notes in computer science · doi:10.1007/978-3-642-40811-3_5 · Cited by 80
Clinical validation of vessel-based registration for correction of brain-shift
Reinertsen, I., Lindseth, F., Unsgaard, G., & Collins, D. L. (2007) · Medical Image Analysis · doi:10.1016/j.media.2007.06.008 · Cited by 78
MORAN, C. M., Pye, S. D., Ellis, W., Janeczko, A., Morris, K. D., McNeilly, A. S., & Fraser, H. M. (2011) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2010.11.010 · Cited by 76
Intraoperative ultrasound-directed resection of pituitary tumors
Ram, Z., Shawker, T. H., Bradford, M. H., Doppman, J. L., & Oldfield, E. H. (1995) · Journal of neurosurgery · doi:10.3171/jns.1995.83.2.0225 · Cited by 75
Moiyadi, A. V., Shetty, P. M., Mahajan, A., Udare, A., & Epari, S. (2013) · Acta Neurochirurgica · doi:10.1007/s00701-013-1881-z · Cited by 74
Mercier, L., Maestro, R. F. D., Petrecca, K., Kochanowska, A., Drouin, S., Yan, C. X. B., Janke, A. L., Chen, S. J.-S., & Collins, D. L. (2010) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-010-0535-3 · Cited by 67
Summarizing and Visualizing Uncertainty in Non-rigid Registration
Risholm, P., Pieper, S., Samset, E., & Wells, W. M. (2010) · Lecture notes in computer science · doi:10.1007/978-3-642-15745-5_68 · Cited by 65
Self-citationIntraoperative Sonography for Neurosurgery
Sosna, J., Barth, M. M., Kruskal, J. B., & Kane, R. A. (2005) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2005.24.12.1671 · Cited by 63
Coburger, J., Scheuerle, A., Thal, D. R., Engelke, J., Hlaváč, M., Wirtz, C. R., & König, R. (2015) · Acta Neurochirurgica · doi:10.1007/s00701-014-2314-3 · Cited by 61 · cited 2×
“We then review three specific applications of these ultrasound technologies to brain tumor resection: (1) intraoperative navigation, (2) assessment of extent of resection, and (3) brain shift monitoring and compensation.”
Coburger, J., Scheuerle, A., Kapapa, T., Engelke, J., Thal, D. R., Wirtz, C. R., & König, R. (2015) · Neurosurgical Review · doi:10.1007/s10143-015-0627-1 · Cited by 56
The role of intraoperative ultrasonography in the diagnosis and management of focal hepatic lesions
Joo, I. (2015) · ULTRASONOGRAPHY · doi:10.14366/usg.15014 · Cited by 56
Šteňo, A., Jezberová, M., Hollý, V., Timárová, G., & Štěňo, J. (2016) · Journal of neurosurgery · doi:10.3171/2015.10.jns151907 · Cited by 55
Olubiyi, O. I., Özdemir, A., Incekara, F., Tie, Y., Dolati, P., Hsu, L., Santagata, S., Chen, Z., Rigolo, L., & Golby, A. J. (2015) · World Neurosurgery · doi:10.1016/j.wneu.2015.04.044 · Cited by 50
Self-citationMercier, L., Fonov, V., Haegelen, C., Maestro, R. F. D., Petrecca, K., & Collins, D. L. (2011) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-011-0620-2 · Cited by 49
Intraoperative Ultrasonography of the Pancreas
Sun, M. R. M., Brennan, D. D., Kruskal, J. B., & Kane, R. A. (2010) · Radiographics · doi:10.1148/rg.307105051 · Cited by 45
Resection of pediatric intracerebral tumors with the aid of intraoperative real-time 3-D ultrasound
Ulrich, N. H., Burkhardt, J., Serra, C., Bernays, R.-L., & Bozinov, O. (2011) · Child s Nervous System · doi:10.1007/s00381-011-1571-1 · Cited by 41
Mercier, L., Araújo, D., Haegelen, C., Maestro, R. F. D., Petrecca, K., & Collins, D. L. (2012) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2012.08.004 · Cited by 30
Validation of a hybrid Doppler ultrasound vessel-based registration algorithm for neurosurgery
Chen, S. J.-S., Reinertsen, I., Coupé, P., Yan, C. X. B., Mercier, L., Maestro, D. R. D., & Collins, D. L. (2012) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-012-0680-y · Cited by 20
Pereira, V. M., Smit-Ockeloen, I., Brina, O., Babić, D., Breeuwer, M. M., Schaller, K., Lövblad, K., & Ruijters, D. (2015) · Operative Neurosurgery · doi:10.1227/neu.0000000000000999 · Cited by 18
Jakola, A. S., Jørgensen, A., Selbekk, T., Michler, R. P., Solheim, O. S., TORP, S. H., Sagberg, L. M., Aadahl, P., & Unsgård, G. (2014) · BMC Medical Imaging · doi:10.1186/1471-2342-14-11 · Cited by 16
Automatic tracking of intraoperative brain surface displacements in brain tumor surgery
Kumar, A. N., Miga, M. I., Pheiffer, T. S., et al. (2014) · doi:10.1109/embc.2014.6943888 · Cited by 11
Bayesian Registration via Local Image Regions: Information, Selection and Marginalization
Toews, M., & Wells, W. (2009) · Information Processing in Medical Imaging · doi:10.1007/978-3-642-02498-6_36 · Cited by 10
Self-citation
Metadata
- Authors
- Sastry, R., Bi, W. L., Pieper, S., Frisken, S., Kapur, T., Wells, W., & Golby, A. J.
- Venue
- Journal of Neuroimaging
- Publisher
- Wiley
- Published
- 2016-08-19
- Volume
- 27
- Issue
- 1
- Pages
- 5-15
- ISSN
- 1051-2284 (ISSN-L)
- 1552-6569
- OpenAlex
- W2515693519
- Cited by
- 167
- References
- 52
- FWCI
- 2.89
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.