Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 200

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Accuracy and Criteria for Localizing Arterial Occlusion With Transcranial Doppler

Demchuk, Andrew M., Christou, Ioannis, Wein, Theodore H., Felberg, Robert A., Malkoff, Marc, Grotta, James C., Alexandrov, Andrei V.·2000·Journal of Neuroimaging

Abstract

The authors determined transcranial Doppler (TCD) accuracy for the proximal internal carotid artery (ICA), distal ICA, proximal middle cerebral artery (MCA), distal MCA, anterior cerebral artery (ACA), posterior cerebral artery (PCA), terminal vertebral artery (tVA), and basilar artery (BA) occlusion in cerebral ischemia patients. Detailed diagnostic criteria were prospectively applied for TCD interpretation independent of angiographic findings. Of 320 consecutive patients referred to the neurosonology service with symptoms of cerebral ischemia, 190 (59%) patients also underwent angiography (MRA or DSA). 48 of those 190 patients had angiographic occlusion and 12 of those 48 patients had involvement of multiple vessels. Median time from TCD until angiography was performed was 1 hour (41 patients had angiography before TCD). TCD showed 40 true positive, 8 false negative, 8 false positive, and 134 true negative studies with sensitivity 83.0%, specificity 94.4%, positive predictive value 83.0%, negative predictive value 94.4%, and accuracy 91.6% to determine all sites of occlusion. Sensitivity for each individual occlusion site was: proximal ICA 94%, distaiiCA 81%, MCA 93%, tVA 56%, BA 60%. Specificity ranged from 96% to 98%. TCD is sensitive and specific in determining the site of the arterial occlusion using detailed diagnostic criteria, including proximal ICA and distal MCA lesions. TCD has the highest accuracy for ICA and MCA occlusions. If the results of TCD are normal, there is at least a 94% chance that angiographic studies will be negative. Key words: ultrasound, transcranial Doppler sonography, stroke, occlusion, angiography.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/jon20001011

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 200

Metadata

Authors
Demchuk, A. M., Christou, I., Wein, T. H., Felberg, R. A., Malkoff, M., Grotta, J. C., & Alexandrov, A. V.
Venue
Journal of Neuroimaging
Publisher
Wiley
Published
2000-01
Volume
10
Issue
1
Pages
1-12
ISSN
  • 1051-2284 (ISSN-L)
  • 1552-6569
OpenAlex
W2204318211
Cited by
200
References
1
FWCI
6.58
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy and Criteria for Localizing Arterial Occlusion With Transcranial Doppler. https://app.cochat.ai/papers/10.1111/jon20001011
The paper
Demchuk, A. M., Christou, I., Wein, T. H., Felberg, R. A., Malkoff, M., Grotta, J. C., & Alexandrov, A. V. (2000). Accuracy and Criteria for Localizing Arterial Occlusion With Transcranial Doppler. Journal of Neuroimaging. https://doi.org/10.1111/jon20001011

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.