The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Comparison of In Vitro Inactivation of SARS CoV‐2 with Hydrogen Peroxide and Povidone‐Iodine Oral Antiseptic Rinses
Open accessAbstract
Purpose: To evaluate the in vitro inactivation of severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) with hydrogen peroxide (H 2 O 2) and povidone‐iodine (PVP‐I) oral antiseptic rinses at clinically recommended concentrations and contact times. Materials and Methods: SARS‐CoV‐2, USA‐WA1/2020 strain virus stock was prepared prior to testing by growing in Vero 76 cells. The culture media for prepared virus stock was minimum essential medium (MEM) with 2% fetal bovine serum (FBS) and 50 µg/mL gentamicin. Test compounds consisting of PVP‐I oral rinse solutions and H 2 O 2 aqueous solutions were mixed directly with the virus solution so that the final concentration was 50% of the test compound and 50% of the virus solution. Thus PVP‐I was tested at concentrations of 0.5%, 1.25%, and 1.5%, and H 2 O 2 was tested at 3% and 1.5% concentrations to represent clinically recommended concentrations. Ethanol and water were evaluated in parallel as standard positive and negative controls. All samples were tested at contact periods of 15 seconds and 30 seconds. Surviving virus from each sample was then quantified by standard end‐point dilution assay and the log reduction value of each compound compared to the negative control was calculated. Results: After the 15‐second and 30‐second contact times, PVP‐I oral antiseptic rinse at all 3 concentrations of 0.5%, 1.25%, and 1.5% completely inactivated SARS‐CoV‐2. The H 2 O 2 solutions at concentrations of 1.5% and 3.0% showed minimal viricidal activity after 15 seconds and 30 seconds of contact time. Conclusions: SARS‐CoV‐2 virus was completely inactivated by PVP‐I oral antiseptic rinse in vitro, at the lowest concentration of 0.5 % and at the lowest contact time of 15 seconds. Hydrogen peroxide at the recommended oral rinse concentrations of 1.5% and 3.0% was minimally effective as a viricidal agent after contact times as long as 30 seconds. Therefore, preprocedural rinsing with diluted PVP‐I in the range of 0.5% to 1.5% may be preferred over hydrogen peroxide during the COVID‐19 pandemic.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chu, D. K., Akl, E. A., Duda, S., Solo, K., Yaacoub, S., Schünemann, H. J., Chu, D. K., Akl, E. A., El-harakeh, A., Bognanni, A., et al. (2020) · The Lancet · doi:10.1016/s0140-6736(20)31142-9 · Cited by 3,843 · cited 2×
“Therefore, a significant amount of attention has been paid during the COVID19 pandemic towards enhancing personal protection equipment (PPE) for dental professionals.(9) Some examples include higher particulate filtration masks (N-95), respirators and face shields.”
BackgroundKariwa, H., Fujii, N., & Takashima, I. (2006) · Dermatology · doi:10.1159/000089211 · Cited by 458
Eggers, M., Koburger-Janssen, T., Eickmann, M., & Zorn, J. (2018) · Infectious Diseases and Therapy · doi:10.1007/s40121-018-0200-7 · Cited by 386
Cited by
Kurakula, M., & Rao, G. S. N. K. (2020) · Journal of Drug Delivery Science and Technology · doi:10.1016/j.jddst.2020.102046 · Cited by 535
Metadata
- Authors
- Bidra, A. S., Pelletier, J. S., Westover, J. B., Frank, S., Brown, S. M., & Tessema, B.
- Venue
- Journal of Prosthodontics
- Publisher
- Wiley
- Published
- 2020-07-24
- Volume
- 29
- Issue
- 7
- Pages
- 599-603
- ISSN
- 1059-941X (ISSN-L)
- 1532-849X
- OpenAlex
- W3040320016
- Cited by
- 172
- References
- 3
- FWCI
- 10.28
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of In Vitro Inactivation of SARS CoV‐2 with Hydrogen Peroxide and Povidone‐Iodine Oral Antiseptic Rinses. https://app.cochat.ai/papers/10.1111/jopr.13220
- The paper
- Bidra, A. S., Pelletier, J. S., Westover, J. B., Frank, S., Brown, S. M., & Tessema, B. (2020). Comparison of In Vitro Inactivation of SARS CoV‐2 with Hydrogen Peroxide and Povidone‐Iodine Oral Antiseptic Rinses. Journal of Prosthodontics. https://doi.org/10.1111/jopr.13220
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.