The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Synergistic interactions between corrosion and wear at titanium‐based dental implant connections: A scoping review
Open accessAbstract
Two‐piece implant systems are mainly used in oral implantology involving an osseointegrated implant connected to an abutment, which supports prosthetic structures. It is well documented that the presence of microgaps, biofilms and oral fluids at the implant‐abutment connection can cause mechanical and biological complications. The aim of this review paper was to report the degradation at the implant‐abutment connection by wear and corrosion processes taking place in the oral cavity. Most of the retrieved studies evaluated the wear and corrosion (tribocorrosion) of titanium‐based materials used for implants and abutments in artificial saliva. Electrochemical and wear tests together with microscopic techniques were applied to validate the tribocorrosion behavior of the surfaces. A few studies inspected the wear on the inner surfaces of the implant connection as a result of fatigue or removal of abutments. The studies reported increased microgaps after fatigue tests. In addition, data suggest that micromovements occurring at the contacting surfaces can increase the wear of the inner surfaces of the connection. Biofilms and/or glycoproteins act as lubricants, although they can also amplify the corrosion of the surfaces. Consequently, loosening of the implant‐abutment connection can take place during mastication. In addition, wear and corrosion debris such as ions and micro‐ and nanoparticles released into the surrounding tissues can stimulate peri‐implant inflammation that can lead to pathologic bone resorption.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Peri‐implant health and disease. A systematic review of current epidemiology
Derks, J., & Tomasi, C. (2015) · Journal of Clinical Periodontology · doi:10.1111/jcpe.12334 · Cited by 1,302
Lang, N. P., Berglundh, T., & on Behalf of Working Group 4 of the Seventh European Workshop on Periodontology (2011) · Journal Of Clinical Periodontology · doi:10.1111/j.1600-051x.2010.01674.x · Cited by 930
Health benefits of saliva: a review
Dodds, M. W. J., Johnson, D. A., & Yeh, C.-K. (2005) · Journal of Dentistry · doi:10.1016/j.jdent.2004.10.009 · Cited by 696
Wear particles, periprosthetic osteolysis and the immune system
Goodman, S. B. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.06.035 · Cited by 340
Cited by
Nano-scale modification of titanium implant surfaces to enhance osseointegration
Souza, J. C. M., Sordi, M. B., Kanazawa, M., Ravindran, S., Henriques, B., Silva, F. S., Aparicio, C., & Cooper, L. F. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.05.045 · Cited by 544
Self-citationMicrobial Community-Driven Etiopathogenesis of Peri-Implantitis
Belibasakis, G. N., & Manoil, D. (2021) · Journal of Dental Research · doi:10.1177/0022034520949851 · Cited by 244
Fit and forget: The future of dental implant therapy via nanotechnology
Gulati, K., Chopra, D., Kocak-Oztug, N. A., & Verron, E. (2023) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2023.114900 · Cited by 89
Metadata
- Authors
- Apaza‐Bedoya, K., Tarce, M., Benfatti, C. A. M., Henriques, B., Mathew, M. T., Teughels, W., & Souza, J. C. M.
- Venue
- Journal of Periodontal Research
- Publisher
- Wiley
- Published
- 2017-06-14
- Volume
- 52
- Issue
- 6
- Pages
- 946-954
- ISSN
- 0022-3484 (ISSN-L)
- 1600-0765
- OpenAlex
- W2626007352
- Cited by
- 168
- References
- 4
- FWCI
- 12.63
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.