The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Sleep endoscopy with simulation bite for prediction of oral appliance treatment outcome
Open accessAbstract
Summary: The aim of this study was to assess the value of drug‐induced sleep endoscopy (DISE) using a custom‐made simulation bite in maximal comfortable protrusion (MCP) of the mandible, in the prediction of treatment outcome for obstructive sleep apnea (OSA) with a mandibular advancement device (MAD). Two hundred patients (74% male; age 46 ± 9 years; apnea–hypopnea index [AHI] 19 ± 13 h−1 sleep; body mass index [BMI] 27 ± 4 kg m−2) with sleep‐disordered breathing underwent DISE with a simulation bite in MCP. One hundred and thirty‐five patients with an established diagnosis of OSA commenced MAD treatment. The associations between the findings during DISE with simulation bite and treatment outcome were evaluated. Treatment response was defined as a reduction in AHI following MAD treatment of ≥ 50% compared to baseline. Overall MAD treatment response in the studied population was 69%. The results of this study demonstrated a statistically significant association between a positive effect of the simulation bite on the upper airway patency during DISE and treatment response with MAD (P < 0.01). The results of this study suggest that the use of a simulation bite in maximal comfortable protrusion (MCP) of the mandible, as used during DISE in patients with OSA, tends to be effective in predicting treatment response of MAD treatment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A New Method for Measuring Daytime Sleepiness: The Epworth Sleepiness Scale
Johns, M. W. (1991) · Sleep · doi:10.1093/sleep/14.6.540 · Cited by 17,364
Mandibular Advancement Devices in 630 Men and Women With Obstructive Sleep Apnea and Snoring
Marklund, M., Stenlund, H., & Franklin, K. A. (2004) · Chest · doi:10.1378/chest.125.4.1270 · Cited by 372
Comparison of a Custom-made and a Thermoplastic Oral Appliance for the Treatment of Mild Sleep Apnea
Vanderveken, O. M., Devolder, A., Marklund, M., Boudewyns, A. N., Braem, M. J., Okkerse, W., Verbraecken, J. A., Franklin, K. A., De Backer, W. A., & Van de Heyning, P. H. (2008) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200701-114oc · Cited by 289
Self-citationTitrated mandibular advancement versus positive airway pressure for sleep apnoea
Gagnadoux, F., Fleury, B., Vielle, B., Pételle, B., Meslier, N., N’Guyen, X. L., Trzepizur, W., & Racineux, J. L. (2009) · European Respiratory Journal · doi:10.1183/09031936.00148208 · Cited by 275 · cited 5×
“worn intra-orally during the night and mechanically protrude the mandible, commonly with a design to gradually protrude the mandible applying a mechanical advancing mechanism (Dieltjens et al., 2012b; Gagnadoux et al., 2009).”
BackgroundResultInfluentialPETRI, N., SVANHOLT, P., SOLOW, B., WILDSCHIØDTZ, G., & WINKEL, P. (2008) · Journal of Sleep Research · doi:10.1111/j.1365-2869.2008.00645.x · Cited by 152
Effect of genioglossus contraction on pharyngeal lumen and airflow in sleep apnoea patients
Oliven, A., Tov, N., Geitini, L., Steinfeld, U., Oliven, R., Schwartz, A. R., & Odeh, M. (2007) · European Respiratory Journal · doi:10.1183/09031936.00131106 · Cited by 85
Cited by
Oral Appliance Treatment for Obstructive Sleep Apnea: An Update
Sutherland, K., Vanderveken, O. M., Tsuda, H., Marklund, M., Gagnadoux, F., Kushida, C. A., Cistulli, P. A., & on behalf of the ORANGE-Registry (Oral Appliance Network on Global Effectiveness) (2014) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.3460 · Cited by 515
Self-citationVanderveken, O. M., Maurer, J. T., Hohenhorst, W., Hamans, E., Lin, H.-S., Vroegop, A. V., Anders, C., de Vries, N., & Van de Heyning, P. H. (2013) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.2658 · Cited by 339
Self-citationEuropean position paper on drug-induced sedation endoscopy (DISE)
De Vito, A., Carrasco Llatas, M., Vanni, A., Bosi, M., Braghiroli, A., Campanini, A., de Vries, N., Hamans, E., Hohenhorst, W., Kotecha, B. T., et al. (2014) · Sleep and Breathing · doi:10.1007/s11325-014-0989-6 · Cited by 295
Self-citationSystematic Review of Drug‐Induced Sleep Endoscopy Scoring Systems
Amos, J. M., Durr, M. L., Nardone, H. C., Baldassari, C. M., Duggins, A., & Ishman, S. L. (2018) · Otolaryngology–Head and Neck Surgery · doi:10.1177/0194599817737966 · Cited by 66
Mandibular Advancement Devices for OSA: An Alternative to CPAP?
Francis, C. E., & Quinnell, T. (2021) · Pulmonary Therapy · doi:10.1007/s41030-020-00137-2 · Cited by 37
Metadata
- Authors
- Vroegop, A. V. M. T., Vanderveken, O. M., Dieltjens, M., Wouters, K., Saldien, V., Braem, M. J., & Van de heyning, P. H.
- Venue
- Journal of Sleep Research
- Publisher
- Wiley
- Published
- 2012-12-04
- Volume
- 22
- Issue
- 3
- Pages
- 348-355
- ISSN
- 0962-1105 (ISSN-L)
- 1365-2869
- OpenAlex
- W2143597665
- Cited by
- 172
- References
- 6
- FWCI
- 4.72
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.