CoChat

Diagnostic accuracy of the Aspergillus ‐specific bronchoalveolar lavage lateral‐flow assay in haematological malignancy patients

Prattes, Juergen, Lackner, Michaela, Eigl, Susanne, Reischies, Frederike, Raggam, Reinhard B., Koidl, Christoph, Flick, Holger, Wurm, Robert, Palfner, Michael, Wölfler, Albert, Neumeister, Peter, Thornton, Christopher R., Krause, Robert, Lass‐Flörl, Cornelia, Hoenigl, Martin · 2015 · Mycoses
Cited by 60

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Summary: We evaluated the performance of the Aspergillus ‐specific lateral‐flow device ( LFD ) test for diagnosing invasive pulmonary aspergillosis ( IPA ) in patients with underlying haematological malignancies. Participating centres were the two Austrian University Hospitals of Graz and Innsbruck. LFD performance was evaluated with 95 bronchoalveolar lavage fluid ( BALF ) samples from 72 patients collected prospectively in Graz, and with 24 BALF bio bank samples from 23 patients (21 samples with probable IPA ) in Innsbruck. Invasive fungal infections were classified according to the revised European Organization of Research and Treatment of Cancer/Mycoses Study Group criteria. Overall, 27 patients (30 samples) had probable IPA , 32 (43 samples) possible and 36 (46 samples) did not fulfil IPA criteria. The vast majority of patients – in particular those with probable IPA – received mould‐active treatment before bronchoscopy. Sensitivity, specificity, positive predictive value and negative‐predictive‐value for probable IPA diagnosis using the BALF ‐ LFD test were 71%, 76%, 35% and 94% for the Graz cohort. Sensitivity of the BALF ‐ LFD test for probable IPA was 57% in Innsbruck bio bank samples. Our results indicate that the BALF ‐ LFD ‐test provides fast results with moderate sensitivities in patients with underlying haematological malignancies. Similar to other diagnostic tests and biomarkers sensitivity of the test may be influenced by ongoing systemic mould‐active treatment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/myc.12343

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 60

Metadata

Authors
Prattes, J., Lackner, M., Eigl, S., Reischies, F., Raggam, R. B., Koidl, C., Flick, H., Wurm, R., Palfner, M., Wölfler, A., Neumeister, P., Thornton, C. R., Krause, R., Lass‐Flörl, C., & Hoenigl, M.
Venue
Mycoses
Publisher
Wiley
Published
2015-06-23
Volume
58
Issue
8
Pages
461-469
ISSN
  • 0027-5557 (ISSN-L)
  • 0933-7407
  • 1439-0507
OpenAlex
W1936387837
Cited by
60
References
6
FWCI
8.67
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnostic accuracy of the Aspergillus ‐specific bronchoalveolar lavage lateral‐flow assay in haematological malignancy patients. https://app.cochat.ai/papers/10.1111/myc.12343
The paper
Prattes, J., Lackner, M., Eigl, S., Reischies, F., Raggam, R. B., Koidl, C., Flick, H., Wurm, R., Palfner, M., Wölfler, A., Neumeister, P., Thornton, C. R., Krause, R., Lass‐Flörl, C., & Hoenigl, M. (2015). Diagnostic accuracy of the Aspergillus ‐specific bronchoalveolar lavage lateral‐flow assay in haematological malignancy patients. Mycoses. https://doi.org/10.1111/myc.12343

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.