Automatic Vagus Nerve Stimulation Triggered by Ictal Tachycardia: Clinical Outcomes and Device Performance—The U.S. E-37 Trial
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: The Automatic Stimulation Mode (AutoStim) feature of the Model 106 Vagus Nerve Stimulation (VNS) Therapy System stimulates the left vagus nerve on detecting tachycardia. This study evaluates performance, safety of the AutoStim feature during a 3-5-day Epilepsy Monitoring Unit (EMU) stay and long- term clinical outcomes of the device stimulating in all modes. MATERIALS AND METHODS: The E-37 protocol (NCT01846741) was a prospective, unblinded, U.S. multisite study of the AspireSR(®) in subjects with drug-resistant partial onset seizures and history of ictal tachycardia. VNS Normal and Magnet Modes stimulation were present at all times except during the EMU stay. Outpatient visits at 3, 6, and 12 months tracked seizure frequency, severity, quality of life, and adverse events. RESULTS: Twenty implanted subjects (ages 21-69) experienced 89 seizures in the EMU. 28/38 (73.7%) of complex partial and secondarily generalized seizures exhibited ≥20% increase in heart rate change. 31/89 (34.8%) of seizures were treated by Automatic Stimulation on detection; 19/31 (61.3%) seizures ended during the stimulation with a median time from stimulation onset to seizure end of 35 sec. Mean duty cycle at six-months increased from 11% to 16%. At 12 months, quality of life and seizure severity scores improved, and responder rate was 50%. Common adverse events were dysphonia (n = 7), convulsion (n = 6), and oropharyngeal pain (n = 3). CONCLUSIONS: The Model 106 performed as intended in the study population, was well tolerated and associated with clinical improvement from baseline. The study design did not allow determination of which factors were responsible for improvements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ben‐Menachem, E., Mañon‐Espaillat, R., Ristanovic, R., Wilder, B. J., Stefan, H., Mirza, W., Tarver, W. B., Wernicke, J. F., & First International Vagus Nerve Stimulation Study Group (1994) · Epilepsia · doi:10.1111/j.1528-1157.1994.tb02482.x · Cited by 683
Prospective Long‐Term Study of Vagus Nerve Stimulation for the Treatment of Refractory Seizures
DeGiorgio, C. M., Schachter, S. C., Handforth, A., Salinsky, M., Thompson, J., Uthman, B., Reed, R., Collin, S., Tecoma, E., Morris, G. L., et al. (2000) · Epilepsia · doi:10.1111/j.1528-1157.2000.tb00325.x · Cited by 479
Fisher, R. S., & Handforth, A. (1999) · Neurology · doi:10.1212/wnl.53.4.666 · Cited by 169
Self-citation
Cited by
Technology of deep brain stimulation: current status and future directions
Krauss, J. K., Lipsman, N., Aziz, T., Boutet, A., Brown, P., Chang, J. W., Davidson, B., Grill, W. M., Hariz, M. I., Horn, A., et al. (2021) · Nature Reviews Neurology · doi:10.1038/s41582-020-00426-z · Cited by 919
Yap, J. Y. Y., Keatch, C., Lambert, E., Woods, W., Stoddart, P. R., & Kameneva, T. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00284 · Cited by 432
Diagnostic challenges in epilepsy: seizure under-reporting and seizure detection
Elger, C. E., & Hoppe, C. (2018) · The Lancet Neurology · doi:10.1016/s1474-4422(18)30038-3 · Cited by 403
Neuromodulation in epilepsy: state-of-the-art approved therapies
Ryvlin, P., Rheims, S., Hirsch, L. J., Sokolov, A., & Jehi, L. (2021) · The Lancet Neurology · doi:10.1016/s1474-4422(21)00300-8 · Cited by 314
Toffa, D. H., Touma, L., El Meskine, T., Bouthillier, A., & Nguyen, D. K. (2020) · Seizure · doi:10.1016/j.seizure.2020.09.027 · Cited by 286
Metadata
- Authors
- Fisher, R. S., Afra, P., Macken, M., Minecan, D. N., Bagić, A., Benbadis, S. R., Helmers, S. L., Sinha, S. R., Slater, J., Treiman, D., Begnaud, J., Raman, P., & Najimipour, B.
- Venue
- Neuromodulation: Technology at the Neural Interface
- Publisher
- Elsevier BV
- Published
- 2016-02
- Volume
- 19
- Issue
- 2
- Pages
- 188-195
- ISSN
- 1094-7159 (ISSN-L)
- OpenAlex
- W2192396192
- Cited by
- 156
- References
- 3
- FWCI
- 3.24
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automatic Vagus Nerve Stimulation Triggered by Ictal Tachycardia: Clinical Outcomes and Device Performance—The U.S. E-37 Trial. https://app.cochat.ai/papers/10.1111/ner.12376
- The paper
- Fisher, R. S., Afra, P., Macken, M., Minecan, D. N., Bagić, A., Benbadis, S. R., Helmers, S. L., Sinha, S. R., Slater, J., Treiman, D., Begnaud, J., Raman, P., & Najimipour, B. (2016). Automatic Vagus Nerve Stimulation Triggered by Ictal Tachycardia: Clinical Outcomes and Device Performance—The U.S. E-37 Trial. Neuromodulation: Technology at the Neural Interface. https://doi.org/10.1111/ner.12376
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.