CoChat

Evaluation of the pylorus with concurrent intraluminal pressure and Endo FLIP in patients with nausea and vomiting

Open access
Snape, W. J., Lin, M. S., Agarwal, N., Shaw, R. E. · 2016 · Neurogastroenterology & Motility
Cited by 117

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Background: Nausea and vomiting occurs in gastroparesis due to diabetes mellitus or unknown causes. The aim of this study was to compare (i) pyloric distensibility to pyloric manometric pressure in patients with nausea and vomiting and (ii) to correlate distensibility with delays in gastric emptying. Methods: Sleeve manometry and Endo FLIP were performed sequentially during the same endoscopy on 114 patients with nausea and vomiting (47 with diabetes mellitus and 67 with idiopathic cause) after a standardized gastric emptying study. The sleeve manometer was positioned fluoroscopically, and the Endo FLIP was placed endoscopically. Manometric pressure using a water‐perfused catheter and distensibility using an Endo FLIP filled with 40 cc of saline were measured from the pylorus. Key Results: The basal pyloric pressure was elevated (>10 mmHg) in 34 patients and was normal in 80 patients. The basal and peak pressures were similar in patient with normal and delayed gastric emptying ( p > 0.05). There was a significant decrease in distensibility (8.0 ± 1.0 mm 2 /mmHg) in patients with gastric retention (>20% at 4 h) compared with patients (12.4 ± 1.4 mm 2 /mmHg) ( p < 0.01) with normal gastric retention (<10%). Pressure measurements from the sleeve manometer and the Endo FLIP correlated ( r = 0.29) ( p < 0.002), and increased Endo FLIP balloon pressure (19.4 ± 1.4 mmHg) ( p < 0.01) was associated with a severe delay in gastric emptying. Conclusions & Inferences: Elevated basal pyloric pressure occurs in 42% of patients with nausea and vomiting and delayed emptying. Decreased pyloric distensibility occurs with nausea, vomiting, and delayed gastric emptying. The Endo FLIP is a useful tool in the evaluation of pyloric function in symptomatic patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/nmo.12772

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

Metadata

Authors
Snape, W. J., Lin, M. S., Agarwal, N., & Shaw, R. E.
Venue
Neurogastroenterology & Motility
Publisher
Wiley
Published
2016-01-27
Volume
28
Issue
5
Pages
758-764
ISSN
  • 1350-1925 (ISSN-L)
  • 1365-2982
OpenAlex
W2254316746
Cited by
117
References
5
FWCI
14.39
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.