Virtual Reality Lead Extraction as a Method for Training New Physicians: A Pilot Study
The DOI matches its Crossref record.
Abstract
Background: It is estimated that the demand for transvenous lead extraction (TLE) has reached an annual extraction rate of nearly 24,000 patients worldwide. Despite technologic advances, TLE still has the potential for significant morbidity and mortality. Complication rates with TLE directly parallel operator experience. However, obtaining adequate training during and postfellowship can be difficult. Given the potential for catastrophic complications and the steep learning curve (up to 300 cases) associated with this procedure, we sought to validate a virtual reality (VR) lead extraction simulator as an innovative training and evaluation tool for physicians new to TLE. Methods: We randomized eight electrophysiology fellows to VR simulator versus conventional training. We compared procedural skill competency between the groups using simulator competency, tactile measurements, markers of proficiency and attitudes, and cognitive abilities battery. Results: Practical skills and simulator complications differed significantly between the VR simulator and conventional training groups. The VR simulator group executed patient preparation and procedure performance better than the conventional group (P < 0.01). All four fellows randomized to conventional training experienced a simulator complication (two superior vena cava [SVC] tears, three right ventricle [RV] avulsions) versus one fellow in the VR simulator group (one SVC tear) (P = 0.02). Tactile measurements revealed a trend toward excess pushing versus pulling forces among the conventionally trained group. The time for lead removal was also significantly higher in the conventional training group (12.46 minutes vs 5.54 minutes, P = 0.02). There was no significant difference in baseline or posttraining cognitive ability. Conclusions: We contend that the implementation of alternative training tools such as a VR simulation model will improve physician training and allow for an innovative pathway to assess the achievement of competency.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kusumoto, F. M., Schoenfeld, M. H., Wilkoff, B. L., Berul, C. I., Birgersdotter-Green, U. M., Carrillo, R., Cha, Y.-M., Clancy, J., Deharo, J.-C., Ellenbogen, K. A., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.09.001 · Cited by 1,199
Virtual reality and the transformation of medical education
Pottle, J. (2019) · Future Healthcare Journal · doi:10.7861/fhj.2019-0036 · Cited by 985
Bongiorni, M. G., Burri, H., Deharo, J. C., Starck, C., Kennergren, C., Saghy, L., Rao, A., Tascini, C., Lever, N., Kutarski, A., et al. (2018) · EP Europace · doi:10.1093/europace/euy050 · Cited by 401
Tricuspid Valve Dysfunction Following Pacemaker or Cardioverter-Defibrillator Implantation
Chang, J. D., Manning, W. J., Ebrille, E., & Zimetbaum, P. J. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.02.055 · Cited by 238
“It has been estimated that 24,000 transvenous lead extractions (TLEs) occur annually worldwide (82), and device infection is the indication in two-thirds (83).”
BackgroundXin, B., Huang, X., Wan, W., Lv, K., Hu, Y., Wang, J., Li, S., Zou, W., Xiao, J., & Liu, T. (2020) · International Orthopaedics · doi:10.1007/s00264-020-04488-y · Cited by 58
Remote Medical Education: Adapting Kern’s Curriculum Design to Tele-teaching
Said, J. T., & Schwartz, A. W. (2021) · Medical Science Educator · doi:10.1007/s40670-020-01186-7 · Cited by 38
Metadata
- Authors
- MAYTIN, M., DAILY, T. P., & CARILLO, R. G.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 2014-12-12
- Volume
- 38
- Issue
- 3
- Pages
- 319-325
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W1550933788
- Cited by
- 54
- References
- 0
- FWCI
- 1.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.