Faster pharmacokinetics and increased patient acceptance of intradermal insulin delivery using a single hollow microneedle in children and adolescents with type 1 diabetes: Pediatric microneedle insulin delivery
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: In an effort to improve compliance with insulin therapy and to accelerate insulin pharmacokinetics, we tested the hypothesis that intradermal insulin delivery using a hollow microneedle causes less pain and leads to faster onset and offset of insulin pharmacokinetics in children and adolescents with type 1 diabetes (T1DM) compared with a subcutaneous, insulin pump catheter. RESEARCH DESIGN AND METHODS: In this repeated measures study, 16 children and adolescents with T1DM received Lispro insulin by microneedle and subcutaneous administration on separate days. Subjects rated the pain of insertion and infusion using a visual analog scale. Blood specimens were collected over 4 h to determine insulin and glucose concentrations. RESULTS: Microneedle insertion pain was significantly lower compared with insertion of the subcutaneous catheter (p = 0.005). Insulin onset time was 22 min faster (p = 0.0004) and offset time was 34 min faster (p = 0.017) after hollow microneedle delivery compared with subcutaneous delivery. CONCLUSIONS: In this study, intradermal insulin delivery using a single, hollow microneedle device resulted in less insertion pain and faster insulin onset and offset in children and adolescents with T1DM. A reduction in pain might improve compliance with insulin delivery. The faster onset and offset times of insulin action may enable closed-loop insulin therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Economic Costs of Diabetes in the U.S. in 2002
American Diabetes Association (2003) · Diabetes Care · doi:10.2337/diacare.26.3.917 · Cited by 4,147
Economic costs of diabetes in the U.S. in 2007
American Diabetes Association (2008) · Diabetes Care · doi:10.2337/dc08-9017 · Cited by 1,323
Morris, A. D., Boyle, D. I., McMahon, A. D., Greene, S. A., MacDonald, T. M., & Newton, R. W. (1997) · The Lancet · doi:10.1016/s0140-6736(97)06234-x · Cited by 507
Models of subcutaneous insulin kinetics. A critical review
Nucci, G., & Cobelli, C. (2000) · Computer Methods and Programs in Biomedicine · doi:10.1016/s0169-2607(00)00071-7 · Cited by 189
Health economics and compliance of vials/syringes versus pen devices: a review of the evidence
Asche, C. V., Shane-McWhorter, L., & Raparla, S. (2010) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0180 · Cited by 83
Cited by
Larrañeta, E., Lutton, R. E. M., Woolfson, A. D., & Donnelly, R. F. (2016) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2016.03.001 · Cited by 964
An overview of clinical and commercial impact of drug delivery systems
Anselmo, A. C., & Mitragotri, S. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.03.053 · Cited by 520
Emerging micro- and nanotechnology based synthetic approaches for insulin delivery
Mo, R., Jiang, T., Di, J., Tai, W., & Gu, Z. (2014) · Chemical Society Reviews · doi:10.1039/c3cs60436e · Cited by 386
Wearable Contact Lens Biosensors for Continuous Glucose Monitoring Using Smartphones
Elsherif, M., Hassan, M. U., Yetisen, A. K., & Butt, H. (2018) · ACS Nano · doi:10.1021/acsnano.8b00829 · Cited by 371
Recent advances of controlled drug delivery using microfluidic platforms
Sanjay, S. T., Zhou, W., Dou, M., Tavakoli, H., Ma, L., Xu, F., & Li, X. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2017.09.013 · Cited by 365
Metadata
- Authors
- Norman, J. J., Brown, M. R., Raviele, N. A., Prausnitz, M. R., & Felner, E. I.
- Venue
- Pediatric Diabetes
- Publisher
- Hindawi Limited
- Published
- 2013-03-21
- Volume
- 14
- Issue
- 6
- Pages
- 459-465
- ISSN
- 1399-543X (ISSN-L)
- OpenAlex
- W2123666561
- Cited by
- 142
- References
- 5
- FWCI
- 6.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.