Prosthetic failures in dental implant therapy
Open accessAbstract
Both fixed and removable implant‐supported prostheses are well‐established methods for replacing missing teeth in partially or fully edentulous patients. Numerous systematic reviews have been performed in recent years to evaluate the survival and complication rates of implant‐retained fixed dental prostheses and implant‐retained overdentures, displaying high 5‐year survival rates ranging from 97.1% for fixed dental prostheses to 95%‐100% for implant‐retained overdentures. However, the survival rates only represent the prostheses remaining in use for a defined follow‐up time, and do not account for the potential prosthetic complications that may have arisen and influence the general success of the implant treatment. The most common technical complications of fixed implant‐retained single crowns are crown fracture, fractures of ceramic implant abutments, and esthetic problems. The predominant technical complication at multiple‐unit, implant‐retained fixed dental prostheses is fracture/chipping of the veneering ceramic. Reported technical complications for implant‐retained overdentures are overdenture fracture or chipping of the veneer materials, whereas mechanical complications include implant fracture, attachment failure, and attachment housing or insert complications. To reduce the risk of such failures, a comprehensive pretreatment diagnostic work‐up is essential, including defining the prosthetic goal with the aid of a wax‐up or set‐up and the associated ideal, prosthetically oriented three‐dimensional implant position. Furthermore, selection of the ideal type of prosthesis, including the respective implant components and materials, is important for clinical long‐term treatment success.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Clinical complications with implants and implant prostheses
Goodacre, C. J., Bernal, G., Rungcharassaeng, K., & Kan, J. Y. K. (2003) · The Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(03)00212-9 · Cited by 1,138
E. Jung, R., Zembic, A., Pjetursson, B. E., Zwahlen, M., & S. Thoma, D. (2012) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2012.02547.x · Cited by 1,019
Self-citationPjetursson, B. E., Brägger, U., Lang, N. P., & Zwahlen, M. (2007) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2007.01439.x · Cited by 786
Self-citationSailer, I., Makarov, N. A., Thoma, D. S., Zwahlen, M., & Pjetursson, B. E. (2015) · Dental Materials · doi:10.1016/j.dental.2015.02.011 · Cited by 762
Self-citationWilson Jr., T. G. (2009) · Journal of Periodontology · doi:10.1902/jop.2009.090115 · Cited by 604
Fixture design and overload influence marginal bone loss and future success in the Brånemark® system
Quirynen, M., Naert, I., & Van Steenberghe, D. (1992) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.1992.030302.x · Cited by 485
Sailer, I., Mühlemann, S., Zwahlen, M., Hämmerle, C. H. F., & Schneider, D. (2012) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2012.02538.x · Cited by 480
Self-citationBuser, D., Chappuis, V., Belser, U. C., & Chen, S. (2017) · Periodontology 2000 · doi:10.1111/prd.12170 · Cited by 479
Pjetursson, B. E., Sailer, I., Makarov, N. A., Zwahlen, M., & Thoma, D. S. (2015) · Dental Materials · doi:10.1016/j.dental.2015.02.013 · Cited by 445
Self-citationSailer, I., Philipp, A., Zembic, A., Pjetursson, B. E., Hämmerle, C. H. F., & Zwahlen, M. (2009) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2009.01787.x · Cited by 368
Self-citationPjetursson, B., Asgeirsson, A., Zwahlen, M., & Sailer, I. (2014) · The International Journal of Oral & Maxillofacial Implants · doi:10.11607/jomi.2014suppl.g5.2 · Cited by 358
Self-citationPapaspyridakos, P., Chen, C., Chuang, S.-K., Weber, H., & Gallucci, G. O. (2012) · PubMed · Cited by 333
Thomason, J. M., Kelly, S. A. M., Bendkowski, A., & Ellis, J. S. (2012) · Journal of Dentistry · doi:10.1016/j.jdent.2011.08.017 · Cited by 321
Implant placement and loading protocols in partially edentulous patients: A systematic review
Gallucci, G. O., Hamilton, A., Zhou, W., Buser, D., & Chen, S. (2018) · Clinical Oral Implants Research · doi:10.1111/clr.13276 · Cited by 288
Sailer, I., Strasding, M., Valente, N. A., Zwahlen, M., Liu, S., & Pjetursson, B. E. (2018) · Clinical Oral Implants Research · doi:10.1111/clr.13277 · Cited by 273
Self-citationBrägger, U., Karoussis, I., Persson, R., Pjetursson, B., Salvi, G., & Lang, N. P. (2005) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2005.01105.x · Cited by 270
Self-citationLinkevicius, T., Vindasiute, E., Puisys, A., Linkeviciene, L., Maslova, N., & Puriene, A. (2013) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2012.02453.x · Cited by 234
Within-subject Comparisons of Implant-supported Mandibular Prostheses: Psychometric Evaluation
de Grandmont, P., Feine, J. S., Taché, R., Boudrias, P., Donohue, W. B., Tanguay, R., & Lund, J. P. (1994) · Journal of Dental Research · doi:10.1177/00220345940730051201 · Cited by 233
Wittneben, J., Buser, D., Salvi, G. E., Bürgin, W., Hicklin, S., & Brägger, U. (2014) · Clinical Implant Dentistry and Related Research · doi:10.1111/cid.12066 · Cited by 232
Mechanical and technical risks in implant therapy.
Salvi, G. E., & Brägger, U. (2009) · PubMed · Cited by 196
Threshold of tactile sensitivity perceived with dental endosseous implants and natural teeth
Hämmerle, C. H. F., Wagner, D., Brägger, U., Lussi, A., Karayiannis, A., Joss, A., & Lang, N. P. (1995) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.1995.060203.x · Cited by 195
Within-subject Comparisons of Implant-supported Mandibular Prostheses: Choice of Prosthesis
Feine, J. S., de Grandmont, P., Boudrias, P., Brien, N., LaMarche, C., Taché, R., & Lund, J. P. (1994) · Journal of Dental Research · doi:10.1177/00220345940730051301 · Cited by 185
Feine, J. S., Maskawi, K., de Grandmont, P., et al. (1994) · Journal of Dental Research · doi:10.1177/00220345940730101001 · Cited by 181
Occlusal overload and bone/implant loss
Naert, I., Duyck, J., & Vandamme, K. (2012) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2012.02550.x · Cited by 181
Slot, W., Raghoebar, G. M., Vissink, A., Slater, J. J. H., & Meijer, H. J. A. (2009) · Journal Of Clinical Periodontology · doi:10.1111/j.1600-051x.2009.01493.x · Cited by 153
Pjetursson, B. E., Zarauz, C., Strasding, M., Sailer, I., Zwahlen, M., & Zembic, A. (2018) · Clinical Oral Implants Research · doi:10.1111/clr.13362 · Cited by 131
Self-citationPieralli, S., Kohal, R., Rabel, K., et al. (2018) · Clinical Oral Implants Research · doi:10.1111/clr.13345 · Cited by 105
Watson, R. M., Jemt, T., Chai, J., Harnett, J., Heath, M., Hutton, J. E., Johns, R., Lithner, B., McKenna, S., McNamara, D. C., et al. (1997) · PubMed · Cited by 104
Zou, D., Wu, Y., Huang, W. H., Wang, F., Wang, S., Zhang, Z., & Zhang, Z. (2013) · The International Journal of Prosthodontics · doi:10.11607/ijp.3485 · Cited by 101
Does the type of implant prosthesis affect outcomes for the completely edentulous arch?
Bryant, S. R., MacDonald-Jankowski, D. S., & Kim, K. (2007) · PubMed · Cited by 91
VALLITTU, P. K. (2018) · Acta Biomaterialia Odontologica Scandinavica · doi:10.1080/23337931.2018.1457445 · Cited by 87
Benić, G. I., Wolleb, K., Sancho‐Puchades, M., & Hämmerle, C. H. F. (2012) · Journal Of Clinical Periodontology · doi:10.1111/j.1600-051x.2011.01840.x · Cited by 84
Mericske‐Stern, R., Oetterli, M., Kiener, P., & Mericske, E. (2002) · PubMed · Cited by 83
Yao, C. J., Cao, C., Bornstein, M. M., & Mattheos, N. (2018) · Clinical Oral Implants Research · doi:10.1111/clr.13286 · Cited by 83
Slot, W., Raghoebar, G. M., Cune, M. S., Vissink, A., & Meijer, H. J. A. (2016) · Journal Of Clinical Periodontology · doi:10.1111/jcpe.12625 · Cited by 75
Francesco, F. D., Marco, G. D., Carnevale, U. A. G., Lanza, M., & Lanza, A. (2018) · Journal of Prosthodontic Research · doi:10.1016/j.jpor.2018.08.006 · Cited by 70
Threshold Value for the Perception of Color Changes of Human Gingiva
Sailer, I., Fehmer, V., Ioannidis, A., Thoma, D. S., & Hämmerle, C. H. F. (2014) · The International Journal of Periodontics & Restorative Dentistry · doi:10.11607/prd.2174 · Cited by 68
Self-citationProsthetic maintenance of different mandibular implant overdentures: A systematic review
Assaf, A., Daas, M., Boittin, A., Eid, N., & Postaire, M. (2017) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2016.10.037 · Cited by 51
Payne, A. G. T., Walton, T., Walton, J. N., & Solomons, Y. F. (2001) · PubMed · Cited by 47
Caramês, J., Marques, D. N. D. S., Barbosa, J. M., Moreira, A., Crispim, P., & Chen, A. (2018) · Clinical Oral Implants Research · doi:10.1111/clr.13393 · Cited by 39
Payne, A. G. T., Walton, J. N., Alsabeeha, N. H. M., Worthington, H. V., & Esposito, M. A. (2009) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd008001 · Cited by 37
Batista, V. E. D. S., Filho, A. J. V., Santiago, J. F., Sônego, M. V., Verri, F. R., dos Santos, D. M., Goiato, M. C., & Pellizzer, E. P. (2018) · International Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.ijom.2018.01.021 · Cited by 37
Keshk, A., Alqutaibi, A. Y., Algabri, R., Swedan, M. S., & Kaddah, A. (2017) · European Journal of Dentistry · doi:10.4103/ejd.ejd_23_17 · Cited by 34
Walton, T. (1998) · PubMed · Cited by 19
Naert, I. E. (2003) · PubMed · Cited by 3
Cited by
Alsharbaty, M. H. M., Naji, G. A., Ghani, B. A., Schagerl, M., Khalil, M. A., & Ali, S. S. (2024) · Scientific Reports · doi:10.1038/s41598-024-68020-7 · Cited by 8
Metadata
- Authors
- Sailer, I., Karasan, D., Todorovic, A., Ligoutsikou, M., & Pjetursson, B. E.
- Venue
- Periodontology 2000
- Publisher
- Wiley
- Published
- 2022-02
- Volume
- 88
- Issue
- 1
- Pages
- 130-144
- ISSN
- 0906-6713 (ISSN-L)
- 1600-0757
- OpenAlex
- W4210282848
- Cited by
- 278
- References
- 45
- FWCI
- 43.94
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).