Skin colour, skin redness and melanin biometric measurements: comparison study between Antera® 3D, Mexameter® and Colorimeter®
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Background: The actual skin colorimeters analyse reflect values from a limited number of broad spectral bands and consequently present limited reproducibility and specificity when measuring skin colour. Here, Antera 3D®, a new device which uses reflectance mapping of seven different light wavelengths spanning the entire visible spectrum, has been compared with Mexameter® MX‐18, an established narrow‐band reflectance spectrophotometer and with Colorimeter® CL‐400, an established tristimulus colorimetric instrument. Methods: Thirty volunteers were exposed to a controlled ultra‐violet B light. Measurements with Antera 3D®, Mexameter® MX‐18 and Colorimeter® CL‐400 were done before treatment and after 2, 7 and 14 days. Results: Antera 3D® showed to have a better sensitivity and specificity than Mexameter® MX‐18 regarding the melanin parameter. A similar sensitivity between Antera 3D® and Mexameter® MX‐18 was found for erythema determination and also for the Commission Internationale de l'Eclairage L*, a* and b* parameters between Antera 3D® and Colorimeter® CL‐400. Good correlations were observed for all the parameters analysed. Repeatability of Mexameter® MX‐18 and Colorimeter® CL‐400 values were lower than that of Antera 3D® for all the parameters analysed. Conclusion: Antera 3D®, such as Mexameter® MX‐18 and Colorimeter® CL‐400, are robust, sensitive and precise equipment for the skin colour analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Clarys, P., Alewaeters, K., Lambrecht, R., & Barel, A. O. (2000) · Skin Research and Technology · doi:10.1034/j.1600-0846.2000.006004230.x · Cited by 381 · cited 2×
“The quantification of experimentally induced colour changes of the skin is a widely used method in dermato-cosmetic research since the colour response can be used as an indicator of skin properties (integrity of the skin barrier and sensitivity), drug properties (concentration, bioavailability), vehicle properties (fo…”
MethodShriver, M. D., & Parra, E. J. (2000) · American Journal of Physical Anthropology · doi:10.1002/(sici)1096-8644(200005)112:1<17::aid-ajpa3>3.0.co;2-d · Cited by 186 · cited 1×
“(13) L* is a good indicator of UV tanning: when L* decreases indicates less lightness, less reflectance which happens when the skin is tanned.”
BackgroundMeasurement of Erythema and Tanning Responses in Human Skin Using a Tri-Stimulus Colorimeter
Seitz, J. C., & Whitmore, C. G. (1988) · Dermatology · doi:10.1159/000248520 · Cited by 151 · cited 1×
“(14) study it is suggested that the b* value would be a good indicator of tanning, in this case it should be noted that this parameter does not seem to be highly related with skin colour variations caused by UVB exposure.”
BackgroundStamatas, G. N., Zmudzka, B. Z., Kollias, N., & Beer, J. Z. (2008) · British Journal of Dermatology · doi:10.1111/j.1365-2133.2008.08642.x · Cited by 102 · cited 3×
“Due to spectral overlap of deoxyhaemoglobin (deoxyHb) and melanin, analysis of reflectance values from a limited number of broad spectral bands is often wrought with artefacts (8).”
BackgroundTakiwaki, H., Overgaard, L., & Serup, J. (1994) · Skin Pharmacology and Physiology · doi:10.1159/000211297 · Cited by 102 · cited 1×
“(15) measured the colour of normal skin with a reflectance spectrometer and tri-stimulus colorimeter and reported that the a* value (measured with the tri-stimulus colorimeter) and E-index (measured with a reflectance spectrometer) showed a strong linear correlation.”
BackgroundBaquié, M., & Kasraee, B. (2014) · Skin Research and Technology · doi:10.1111/srt.12109 · Cited by 82 · cited 8×
“The reason associated with this phenomenon is due to a partial overlap in wavelengths, which leads to erroneous measurements of melanin which can be falsely biased by a fluctuation in skin erythema and vice versa (5, 8).”
BackgroundResultInfluentialPark, Suh, & Youn (1999) · Clinical and Experimental Dermatology · doi:10.1046/j.1365-2230.1999.00488.x · Cited by 60
Suh, K. ‐., Roh, H. ‐., Choi, S. ‐., Jeon, Y. ‐., Doh, K. ‐., Bae, J. ‐., & Kim, S. ‐. (2007) · Skin Research and Technology · doi:10.1111/j.1600-0846.2007.00213.x · Cited by 57 · cited 2×
“The initial inflammatory (erythematous) response in the skin peaks within 2 days and the following increased formation of melanin pigment (melanogenesis) peaks at about 4–7 days and are both readily accessible for assessment by the naked eye or by bioengineering methods (2, 3).”
BackgroundMethodDornelles, S. I. T., Goldim, J. R., & Cestari, T. F. (2004) · Photochemistry and Photobiology · doi:10.1562/yg-03-08.1 · Cited by 53
Park, S., Huh, C., Choe, Y., & Youn, J. (2002) · Photodermatology, Photoimmunology & Photomedicine · doi:10.1034/j.1600-0781.2002.180104.x · Cited by 41 · cited 7×
“(2002) (1) the index of a* increased significantly on days 1 and 2 after UV exposure in the direction of the mean colour of haemoglobin.”
BackgroundInfluential
Cited by
Kim, J. Y., Kim, J., Ahn, Y., Lee, E. J., Hwang, S., Almurayshid, A., Park, K., Chung, H., Kim, H. J., Lee, S., et al. (2020) · Pigment Cell & Melanoma Research · doi:10.1111/pcmr.12838 · Cited by 94
Damkerngsuntorn, W., Rerknimitr, P., Panchaprateep, R., Tangkijngamvong, N., Kumtornrut, C., Kerr, S. J., Asawanonda, P., Tantisira, M. H., & Khemawoot, P. (2020) · The Journal of Alternative and Complementary Medicine · doi:10.1089/acm.2019.0325 · Cited by 34
A review of melanin sensor devices
Kanellis, V. G. (2019) · Biophysical Reviews · doi:10.1007/s12551-019-00581-8 · Cited by 29
“…Commercially available as a standalone device or as a MX18 probe that is connected to the company’s phototherapy device (Bhargava et al. 2016; Matias et al. 2015; Van Der Wal et al. 2013) Colorimeter (CL 400 probe) (Courage-Khazaka, Germany) Tristimulus reflectance colorimetry using…”
BackgroundOpatha, S. A. T., Chutoprapat, R., Khankaew, P., Titapiwatanakun, V., Ruksiriwanich, W., & Boonpisuttinant, K. (2024) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2023.123738 · Cited by 25
Metadata
- Authors
- Matias, A. R., Ferreira, M., Costa, P., & Neto, P.
- Venue
- Skin Research and Technology
- Publisher
- Wiley
- Published
- 2015-02-03
- Volume
- 21
- Issue
- 3
- Pages
- 346-362
- ISSN
- 0909-752X (ISSN-L)
- 1600-0846
- OpenAlex
- W2110918402
- Cited by
- 158
- References
- 12
- FWCI
- 3.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Skin colour, skin redness and melanin biometric measurements: comparison study between Antera® 3D, Mexameter® and Colorimeter®. https://app.cochat.ai/papers/10.1111/srt.12199
- The paper
- Matias, A. R., Ferreira, M., Costa, P., & Neto, P. (2015). Skin colour, skin redness and melanin biometric measurements: comparison study between Antera® 3D, Mexameter® and Colorimeter®. Skin Research and Technology. https://doi.org/10.1111/srt.12199
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.