The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Implementation of a patient blood management monitoring and feedback program significantly reduces transfusions and costs
Abstract
BACKGROUND: Patient blood management (PBM) measures have been shown to be effective in reducing transfusions while maintaining patient outcome. The issuance of transfusion guidelines is seen as being key to the success of PBM programs. As the introduction of guidelines alone did not visibly reduce transfusions in our center, a monitoring and feedback program was established. The aim of our study was to show the effectiveness of such measures in reducing transfusions and cost. STUDY DESIGN AND METHODS: We designed a prospective, interventional cohort study with a 3‐year time frame (January 1, 2012 to December 31, 2014). In total, 101,794 patients aged 18 years or older were included. The PBM monitoring and feedback program was introduced on January 1, 2014, with the subsequent issuance of quarterly reporting. RESULTS: Within the first year of introduction, transfusion of all allogeneic blood products per 1000 patients was reduced by 27% (red blood cell units, −24%; platelet units, −25%; and fresh‐frozen plasma units, −37%; all p < 0.001) leading to direct allogeneic blood product related savings of more than 2 million USD. The number of blood products transfused per case was significantly reduced from 9 ± 19 to 7 ± 14 (p < 0.001). With an odds ratio of 0.86 (95% confidence interval, 0.82‐0.91), the introduction of our PBM monitoring and feedback program was a significant independent factor in the reduction of transfusion probability (p < 0.001). CONCLUSION: Our PBM monitoring and feedback program was highly efficacious in reducing the transfusion of allogeneic blood products and transfusion‐related costs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Weber, C. F., Görlinger, K., Meininger, D., Herrmann, E., Bingold, T., Moritz, A., Cohn, L. H., & Zacharowski, K. (2012) · Anesthesiology · doi:10.1097/aln.0b013e318264c644 · Cited by 625
Cited by
Patient Blood Management: Recommendations From the 2018 Frankfurt Consensus Conference
Mueller, M. M., Van Remoortel, H., Meybohm, P., Aranko, K., Aubron, C., Burger, R., Carson, J. L., Cichutek, K., De Buck, E., Devine, D., et al. (2019) · JAMA · doi:10.1001/jama.2019.0554 · Cited by 632
Althoff, F. C., Neb, H., Herrmann, E., Trentino, K. M., Vernich, L., Füllenbach, C., Freedman, J., Waters, J. H., Farmer, S., Leahy, M. F., et al. (2019) · Annals of Surgery · doi:10.1097/sla.0000000000003095 · Cited by 316
Rössler, J., Schoenrath, F., Seifert, B., Kaserer, A., Spahn, G. H., Falk, V., & Spahn, D. R. (2020) · British Journal of Anaesthesia · doi:10.1016/j.bja.2019.09.016 · Cited by 132
Self-citation
Metadata
- Authors
- Mehra, T., Seifert, B., Bravo‐Reiter, S., Wanner, G., Dutkowski, P., Holubec, T., Moos, R. M., Volbracht, J., Manz, M. G., & Spahn, D. R.
- Venue
- Transfusion
- Publisher
- Wiley
- Published
- 2015-08-11
- Volume
- 55
- Issue
- 12
- Pages
- 2807-2815
- ISSN
- 0041-1132 (ISSN-L)
- 1537-2995
- OpenAlex
- W1742774919
- Cited by
- 177
- References
- 1
- FWCI
- 8.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Implementation of a patient blood management monitoring and feedback program significantly reduces transfusions and costs. https://app.cochat.ai/papers/10.1111/trf.13260
- The paper
- Mehra, T., Seifert, B., Bravo‐Reiter, S., Wanner, G., Dutkowski, P., Holubec, T., Moos, R. M., Volbracht, J., Manz, M. G., & Spahn, D. R. (2015). Implementation of a patient blood management monitoring and feedback program significantly reduces transfusions and costs. Transfusion. https://doi.org/10.1111/trf.13260
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.