The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A meta-analysis and meta-regression of outcomes including biliary complications in donation after cardiac death liver transplantation
Abstract
Donation after cardiac death (DCD) liver transplantation is increasingly common but concerns exist over the development of biliary complications and ischemic cholangiopathy (IC). This study aimed to compare outcomes between DCD and donation after brain death (DBD) liver grafts. Studies reporting on post-transplantation outcomes after Maastricht category III DCD liver transplantation were screened for inclusion. Odds ratios (OR) with 95% confidence intervals were produced using random-effects models for the incidence of biliary complications, IC, graft and recipient survival. Meta-regression was undertaken to identify between-study predictors of effect size for biliary complications and IC. PROSPERO Record: CRD42012002113. Twenty-five studies with 62 184 liver transplant recipients (DCD = 2478 and DBD = 59 706) were included. In comparison with DBD, there was a significant increase in biliary complications [OR = 2.4 (1.9, 3.1); P < 0.00001] and IC [OR = 10.5 (5.7, 19.5); P < 0.00001] following DCD liver transplantation. In comparison with DBD, at 1 year [OR = 0.7 (0.5, 0.8); P = 0.0002] and 3 years [OR = 0.6 (0.5, 0.8); P = 0.001], there was a significant decrease in graft survival following DCD liver transplantation. At 1 year, there was also a nonsignificant decrease [OR = 0.8 (0.6, 1.0); P = 0.08] and by 3 years a significant decrease [OR = 0.7 (0.5, 1.0); P = 0.04] found in recipient survival following DCD liver transplantation. Eleven factors were entered into meta-regression models, but none explained the variability in effect size between studies. DCD liver transplantation is associated with an increase in biliary complications, IC, graft loss and mortality. Significant unexplained differences in effect size exist between centers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sterne, J. A. C., Sutton, A. J., Ioannidis, J. P. A., Terrin, N., Jones, D. R., Lau, J., Carpenter, J., Rucker, G., Harbord, R. M., Schmid, C. H., et al. (2011) · BMJ · doi:10.1136/bmj.d4002 · Cited by 7,709 · cited 1×
“Publication bias was assessed by funnel plots and a significance test performed for analyses containing greater than 10 studies [42].”
MethodA modified test for small‐study effects in meta‐analyses of controlled trials with binary endpoints
Harbord, R. M., Egger, M., & Sterne, J. A. C. (2006) · Statistics in Medicine · doi:10.1002/sim.2380 · Cited by 2,267
Cited by
Hypothermic Machine Perfusion in Liver Transplantation — A Randomized Trial
van Rijn, R., Schurink, I. J., de Vries, Y., van den Berg, A. P., Cortes Cerisuelo, M., Darwish Murad, S., Erdmann, J. I., Gilbo, N., de Haas, R. J., Heaton, N., et al. (2021) · New England Journal of Medicine · doi:10.1056/nejmoa2031532 · Cited by 649
Dutkowski, P., Polak, W. G., Muiesan, P., Schlegel, A., Verhoeven, C. J., Scalera, I., DeOliveira, M. L., Kron, P., & Clavien, P.-A. (2015) · Annals of Surgery · doi:10.1097/sla.0000000000001473 · Cited by 377
Schlegel, A., Muller, X., Kalisvaart, M., Muellhaupt, B., Perera, M. T. P. R., Isaac, J. R., Clavien, P.-A., Muiesan, P., & Dutkowski, P. (2019) · Journal of Hepatology · doi:10.1016/j.jhep.2018.10.005 · Cited by 326
Metadata
- Authors
- O'Neill, S., Roebuck, A., Khoo, E., Wigmore, S. J., & Harrison, E. M.
- Venue
- Transplant International
- Publisher
- Frontiers Media SA
- Published
- 2014-10-18
- Volume
- 27
- Issue
- 11
- Pages
- 1159-1174
- ISSN
- 0934-0874 (ISSN-L)
- OpenAlex
- W2034547620
- Cited by
- 168
- References
- 2
- FWCI
- 1.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.