The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Outcomes of DCD liver transplantation using organs treated by hypothermic oxygenated perfusion before implantation
Open accessAbstract
BACKGROUND & AIMS Donation after circulatory death (DCD) liver transplantation is known for potentially worse outcomes because of higher rates of graft non-function or irreversible cholangiopathy. The impact of machine liver perfusion techniques on these complications remains elusive. We aimed to provide data on 5-year outcomes in patients receiving DCD liver transplants, after donor organs had been treated by hypothermic oxygenated perfusion (HOPE). METHODS Fifty HOPE-treated DCD liver transplants performed in Zurich between 2012 and 3/2017 were matched with 50 primary donation after brain death (DBD) liver transplants, and with 50 untreated DCD liver transplants in Birmingham. Match factors focussed on short cold ischaemia, comparable recipient age and low recipient laboratory model for end-stage liver disease scores. Primary endpoints were post-transplant complications, and non-tumour-related patient death or graft loss. RESULTS Despite extended donor warm ischaemia, HOPE-treated DCD liver transplants achieved similar overall graft survival, compared to standard DBD liver transplants. Particularly, graft loss due to any non-tumour-related causes occurred in 8% (4/50) of cases. In contrast, untreated DCD livers resulted in non-tumour-related graft failure in one-third (16/50) of cases (p = 0.005), despite significantly (p <0.001) shorter functional donor warm ischaemia. Five-year graft survival, censored for tumour death, was 94% for HOPE-treated DCD liver transplants vs. 78% in untreated DCD liver transplants (p = 0.024). CONCLUSIONS The 5-year outcomes of HOPE-treated DCD liver transplants were similar to those of DBD primary transplants and superior to those of untreated DCD liver transplants, despite much higher risk. These results suggest that a simple end-ischaemic perfusion approach is very effective and may open the field for safe utilisation of extended DCD liver grafts. LAY SUMMARY Machine perfusion techniques are currently being introduced into the clinic, with the aim of optimising injured grafts prior to implantation. While short-term effects of machine liver perfusion have been frequently reported in terms of hepatocellular enzyme release and early graft function, the long-term benefit on irreversible graft loss has been unclear. Herein, we report on 5-year graft survival in donation after cardiac death livers, treated either by conventional cold storage, or by 1-2 h of hypothermic oxygenated perfusion (HOPE) after cold storage. Graft loss was significantly less in HOPE-treated livers, despite longer donor warm ischaemia times. Therefore, HOPE after cold storage appears to be a simple and effective method to treat high-risk livers before implantation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dindo, D., Demartines, N., & Clavien, P.-A. (2004) · Annals of Surgery · doi:10.1097/01.sla.0000133083.54934.ae · Cited by 31,378
Self-citationThe Comprehensive Complication Index: A Novel Continuous Scale to Measure Surgical Morbidity
Slankamenac, K., Graf, R., Barkun, J., Puhan, M. A., & Clavien, P.-A. (2013) · Annals of Surgery · doi:10.1097/sla.0b013e318296c732 · Cited by 1,773
Self-citationOlthoff, K. M., Kulik, L., Samstein, B., Kaminski, M., Abecassis, M., Emond, J., Shaked, A., & Christie, J. D. (2010) · Liver Transplantation · doi:10.1002/lt.22091 · Cited by 1,256
A randomized trial of normothermic preservation in liver transplantation
for the Consortium for Organ Preservation in Europe, Nasralla, D., Coussios, C. C., Mergental, H., Akhtar, M. Z., Butler, A. J., Ceresa, C. D. L., Chiocchia, V., Dutton, S. J., García-Valdecasas, J. C., et al. (2018) · Nature · doi:10.1038/s41586-018-0047-9 · Cited by 1,199
Self-citationRavikumar, R., Jassem, W., Mergental, H., Heaton, N., Mirza, D., Perera, M. T. P. R., Quaglia, A., Holroyd, D., Vogel, T., Coussios, C. C., et al. (2016) · American Journal of Transplantation · doi:10.1111/ajt.13708 · Cited by 496
Self-citationDutkowski, P., Polak, W. G., Muiesan, P., Schlegel, A., Verhoeven, C. J., Scalera, I., DeOliveira, M. L., Kron, P., & Clavien, P.-A. (2015) · Annals of Surgery · doi:10.1097/sla.0000000000001473 · Cited by 377
Self-citationObservations on the ex situ perfusion of livers for transplantation
Watson, C. J. E., Kosmoliaptsis, V., Pley, C., Randle, L., Fear, C., Crick, K., Gimson, A. E., Allison, M., Upponi, S., Brais, R., et al. (2018) · American Journal of Transplantation · doi:10.1111/ajt.14687 · Cited by 355
HOPE for human liver grafts obtained from donors after cardiac death
Dutkowski, P., Schlegel, A., de Oliveira, M., Müllhaupt, B., Neff, F., & Clavien, P.-A. (2014) · Journal of Hepatology · doi:10.1016/j.jhep.2013.11.023 · Cited by 333
Self-citationGuarrera, J. V., Henry, S. D., Samstein, B., Reznik, E., Musat, C., Lukose, T. I., Ratner, L. E., Brown, R. S., Kato, T., & Emond, J. C. (2015) · American Journal of Transplantation · doi:10.1111/ajt.12958 · Cited by 323
Protective mechanisms of end-ischemic cold machine perfusion in DCD liver grafts
Schlegel, A., Rougemont, O. D., Graf, R., Clavien, P.-A., & Dutkowski, P. (2013) · Journal of Hepatology · doi:10.1016/j.jhep.2012.10.004 · Cited by 274
Self-citation
Cited by
Liver regeneration and inflammation: from fundamental science to clinical applications
Campana, L., Esser, H., Huch, M., & Forbes, S. (2021) · Nature Reviews Molecular Cell Biology · doi:10.1038/s41580-021-00373-7 · Cited by 307
Yamada, N., Karasawa, T., Wakiya, T., Sadatomo, A., Ito, H., Kamata, R., Watanabe, S., Komada, T., Kimura, H., Sanada, Y., et al. (2020) · American Journal of Transplantation · doi:10.1111/ajt.15773 · Cited by 278
Czigany, Z., Pratschke, J., Froněk, J., Guba, M., Schöning, W., Raptis, D. A., Andrassy, J., Kramer, M., Strnad, P., Tolba, R. H., et al. (2021) · Annals of Surgery · doi:10.1097/sla.0000000000005110 · Cited by 255
Metadata
- Authors
- Schlegel, A., Muller, X., Kalisvaart, M., Muellhaupt, B., Perera, M. T. P. R., Isaac, J. R., Clavien, P.-A., Muiesan, P., & Dutkowski, P.
- Venue
- Journal of Hepatology
- Publisher
- Elsevier BV
- Published
- 2019-01
- Volume
- 70
- Issue
- 1
- Pages
- 50-57
- ISSN
- 0168-8278 (ISSN-L)
- OpenAlex
- W2897545437
- Cited by
- 326
- References
- 26
- FWCI
- 30.16
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Outcomes of DCD liver transplantation using organs treated by hypothermic oxygenated perfusion before implantation. https://app.cochat.ai/papers/10.1016/j.jhep.2018.10.005
- The paper
- Schlegel, A., Muller, X., Kalisvaart, M., Muellhaupt, B., Perera, M. T. P. R., Isaac, J. R., Clavien, P.-A., Muiesan, P., & Dutkowski, P. (2019). Outcomes of DCD liver transplantation using organs treated by hypothermic oxygenated perfusion before implantation. Journal of Hepatology. https://doi.org/10.1016/j.jhep.2018.10.005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.