Capillary versus venous haemoglobin determination in the assessment of healthy blood donors
The DOI matches its Crossref record.
Abstract
Background and Objectives: To determine the accuracy of fingerstick haemoglobin assessment in blood donors, the performance of a portable haemoglobinometer (HemoCue Hb 201+) was prospectively compared with that of an automated haematology analyzer (Cell‐Dyn 4000). Haemoglobin values obtained by the latter were used as the ‘true’ result. Material and Methods: Capillary fingerstick samples were assayed by HemoCue in 150 donors. Fingerstick samples from two sites, one on each hand, were obtained from a subset of 50 subjects. Concurrent venous samples were tested using both HemoCue and Cell‐Dyn devices. Results: Capillary haemoglobin values (HemoCue) were significantly greater than venous haemoglobin values (HemoCue), which in turn were significantly greater than venous haemoglobin values by Cell‐Dyn (mean ± SD: 14·05 ± 1·51, 13·89 ± 1·31, 13·62 ± 1·23, respectively; P < 0·01 for all comparisons among groups). Nine donors (6%) passed haemoglobin screening criteria (≥12·5 g/dl) by capillary HemoCue, but were deferred by Cell‐Dyn values (false‐pass). Five donors (3%) were deferred by capillary sampling, but passed by Cell‐Dyn (false‐fail). Substantial variability in repeated fingerstick HemoCue results was seen (mean haemoglobin 13·72 vs. 13·70 g/dl, absolute mean difference between paired samples 0·76 g/dl). Hand dominance was not a factor. Conclusions: Capillary samples assessed via a portable device yielded higher haemoglobin values than venous samples assessed on an automated analyzer. False‐pass and false‐fail rates were low and acceptable in the donor screening setting, with ‘true’ values not differing by a clinically significant degree from threshold values used to assess acceptability for blood donation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, capillary [Hb] can be marginally higher than that in venous blood.42–45”
From Hemoglobin concentration, total hemoglobin mass and plasma volume in patients: implications for anemia (2017) · cites this paper as [42]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 31
- Price TH, 2008, Standards for blood banks and transfusion services, 45
- 10.1111/j.1423-0410.1986.tb04850.x · doi:10.1111/j.1423-0410.1986.tb04850.x
- 10.1111/j.1365-3148.1994.tb00275.x · doi:10.1111/j.1365-3148.1994.tb00275.x
- 10.1046/j.1537-2995.2003.00316.x · doi:10.1046/j.1537-2995.2003.00316.x
- 10.1046/j.1537-2995.1977.17377196362.x · doi:10.1046/j.1537-2995.1977.17377196362.x
- 10.1016/S0887-7963(05)80052-5 · DOI
- HemoCue, 2010, HemoCue® Hb 201+ Operating Manual
- 10.1590/S0034-89102004000400017 · doi:10.1590/s0034-89102004000400017
- 10.1177/0310057X9202000419 · DOI
- Zwart A, 1987, Determination of total haemoglobin in whole blood; further tests of the “Hemocue” method, Clin Chem, 33, 2307, 10.1093/clinchem/33.12.2307 · doi:10.1093/clinchem/33.12.2307
- Schenck von H, 1986, Evaluation of Hemocue, a device for determining haemoglobin, Clin Chem, 32, 526, 10.1093/clinchem/32.3.526 · DOI · Paper page
- 10.1111/j.1423-0410.2009.01285.x · DOI · Paper page
- Badevant B, 2011, Retrospective analysis of pre‐donation hemoglobin screening implementation in a French regional blood establishment (EFS Pays De La Loire), Vox Sang, 101, 144
- 10.1016/j.transci.2007.01.010 · DOI
- 10.1016/j.transci.2004.11.004 · DOI
- 10.1111/j.1423-0410.2007.00978.x · doi:10.1111/j.1423-0410.2007.00978.x
- 10.1590/S0036-36342002000300005 · DOI · Paper page
- 10.3109/00365518809085796 · doi:10.3109/00365518809085796
- 10.1152/jappl.1978.45.3.414 · DOI · Paper page
- 10.1111/j.1365-2141.1993.tb03354.x · DOI
- 10.1046/j.1537-2995.1988.28689059031.x · doi:10.1046/j.1537-2995.1988.28689059031.x
- 10.1046/j.1537-2995.2003.00372.x · doi:10.1046/j.1537-2995.2003.00372.x
- 10.1111/j.1365-2257.2005.00678.x · doi:10.1111/j.1365-2257.2005.00678.x
- 10.1111/j.1537-2995.2008.02023.x · doi:10.1111/j.1537-2995.2008.02023.x
- 10.1111/j.1537-2995.2011.03183.x · DOI · Paper page
- 10.1111/j.1537-2995.2005.00574.x · doi:10.1111/j.1537-2995.2005.00574.x
- 10.1111/j.1537-2995.2005.00624.x · doi:10.1111/j.1537-2995.2005.00624.x
- 10.1007/s00134-006-0461-6 · DOI
- 10.1111/j.1537-2995.2011.03488.x · DOI
- 10.1111/j.1537-2995.2010.02865.x · DOI · Paper page
- 10.1111/j.1537-2995.2008.01664.x · DOI
Cited by
Otto, J. M., Plumb, J. O. M., Clissold, E., Kumar, S. B., Wakeham, D. J., Schmidt, W., Grocott, M. P. W., Richards, T., & Montgomery, H. E. (2017) · Haematologica · doi:10.3324/haematol.2017.169680 · Cited by 93
“One hundred and nine patients (61% male: mean (IQR) age 52 (36-64) years)”
Background
Metadata
- Authors
- Patel, A. J., Wesley, R., Leitman, S. F., & Bryant, B. J.
- Affiliations
- Department of Transfusion Medicine Clinical Center National Institutes of Health Bethesda MD USA
- Department of Biostatistics Services Clinical Center National Institutes of Health Bethesda MD USA
- Venue
- Vox Sanguinis
- Publisher
- Wiley
- Published
- 2013-01-07
- Volume
- 104
- Issue
- 4
- Pages
- 317-323
- ISSN
- 0042-9007
- 1423-0410
- Cited by
- 92
- References
- 0
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Capillary versus venous haemoglobin determination in the assessment of healthy blood donors. https://app.cochat.ai/papers/10.1111/vox.12006
- The paper
- Patel, A. J., Wesley, R., Leitman, S. F., & Bryant, B. J. (2013). Capillary versus venous haemoglobin determination in the assessment of healthy blood donors. Vox Sanguinis. https://doi.org/10.1111/vox.12006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.