CoChat

Capillary versus venous haemoglobin determination in the assessment of healthy blood donors

Patel, A. J., Wesley, R., Leitman, S. F., Bryant, B. J. · 2013 · Vox Sanguinis
Cited by 92

The DOI matches its Crossref record.

Abstract

Background and Objectives: To determine the accuracy of fingerstick haemoglobin assessment in blood donors, the performance of a portable haemoglobinometer (HemoCue Hb 201+) was prospectively compared with that of an automated haematology analyzer (Cell‐Dyn 4000). Haemoglobin values obtained by the latter were used as the ‘true’ result. Material and Methods: Capillary fingerstick samples were assayed by HemoCue in 150 donors. Fingerstick samples from two sites, one on each hand, were obtained from a subset of 50 subjects. Concurrent venous samples were tested using both HemoCue and Cell‐Dyn devices. Results: Capillary haemoglobin values (HemoCue) were significantly greater than venous haemoglobin values (HemoCue), which in turn were significantly greater than venous haemoglobin values by Cell‐Dyn (mean ± SD: 14·05 ± 1·51, 13·89 ± 1·31, 13·62 ± 1·23, respectively; P < 0·01 for all comparisons among groups). Nine donors (6%) passed haemoglobin screening criteria (≥12·5 g/dl) by capillary HemoCue, but were deferred by Cell‐Dyn values (false‐pass). Five donors (3%) were deferred by capillary sampling, but passed by Cell‐Dyn (false‐fail). Substantial variability in repeated fingerstick HemoCue results was seen (mean haemoglobin 13·72 vs. 13·70 g/dl, absolute mean difference between paired samples 0·76 g/dl). Hand dominance was not a factor. Conclusions: Capillary samples assessed via a portable device yielded higher haemoglobin values than venous samples assessed on an automated analyzer. False‐pass and false‐fail rates were low and acceptable in the donor screening setting, with ‘true’ values not differing by a clinically significant degree from threshold values used to assess acceptability for blood donation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/vox.12006

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 31

  1. Price TH, 2008, Standards for blood banks and transfusion services, 45
  2. 10.1111/j.1423-0410.1986.tb04850.x · doi:10.1111/j.1423-0410.1986.tb04850.x
  3. 10.1111/j.1365-3148.1994.tb00275.x · doi:10.1111/j.1365-3148.1994.tb00275.x
  4. 10.1046/j.1537-2995.2003.00316.x · doi:10.1046/j.1537-2995.2003.00316.x
  5. 10.1046/j.1537-2995.1977.17377196362.x · doi:10.1046/j.1537-2995.1977.17377196362.x
  6. 10.1016/S0887-7963(05)80052-5 · DOI
  7. HemoCue, 2010, HemoCue® Hb 201+ Operating Manual
  8. 10.1590/S0034-89102004000400017 · doi:10.1590/s0034-89102004000400017
  9. 10.1177/0310057X9202000419 · DOI
  10. Zwart A, 1987, Determination of total haemoglobin in whole blood; further tests of the “Hemocue” method, Clin Chem, 33, 2307, 10.1093/clinchem/33.12.2307 · doi:10.1093/clinchem/33.12.2307
  11. Schenck von H, 1986, Evaluation of Hemocue, a device for determining haemoglobin, Clin Chem, 32, 526, 10.1093/clinchem/32.3.526 · DOI · Paper page
  12. 10.1111/j.1423-0410.2009.01285.x · DOI · Paper page
  13. Badevant B, 2011, Retrospective analysis of pre‐donation hemoglobin screening implementation in a French regional blood establishment (EFS Pays De La Loire), Vox Sang, 101, 144
  14. 10.1016/j.transci.2007.01.010 · DOI
  15. 10.1016/j.transci.2004.11.004 · DOI
  16. 10.1111/j.1423-0410.2007.00978.x · doi:10.1111/j.1423-0410.2007.00978.x
  17. 10.1590/S0036-36342002000300005 · DOI · Paper page
  18. 10.3109/00365518809085796 · doi:10.3109/00365518809085796
  19. 10.1152/jappl.1978.45.3.414 · DOI · Paper page
  20. 10.1111/j.1365-2141.1993.tb03354.x · DOI
  21. 10.1046/j.1537-2995.1988.28689059031.x · doi:10.1046/j.1537-2995.1988.28689059031.x
  22. 10.1046/j.1537-2995.2003.00372.x · doi:10.1046/j.1537-2995.2003.00372.x
  23. 10.1111/j.1365-2257.2005.00678.x · doi:10.1111/j.1365-2257.2005.00678.x
  24. 10.1111/j.1537-2995.2008.02023.x · doi:10.1111/j.1537-2995.2008.02023.x
  25. 10.1111/j.1537-2995.2011.03183.x · DOI · Paper page
  26. 10.1111/j.1537-2995.2005.00574.x · doi:10.1111/j.1537-2995.2005.00574.x
  27. 10.1111/j.1537-2995.2005.00624.x · doi:10.1111/j.1537-2995.2005.00624.x
  28. 10.1007/s00134-006-0461-6 · DOI
  29. 10.1111/j.1537-2995.2011.03488.x · DOI
  30. 10.1111/j.1537-2995.2010.02865.x · DOI · Paper page
  31. 10.1111/j.1537-2995.2008.01664.x · DOI

Cited by

See all 92

Metadata

Authors
Patel, A. J., Wesley, R., Leitman, S. F., & Bryant, B. J.
Affiliations
  • Department of Transfusion Medicine Clinical Center National Institutes of Health Bethesda MD USA
  • Department of Biostatistics Services Clinical Center National Institutes of Health Bethesda MD USA
Venue
Vox Sanguinis
Publisher
Wiley
Published
2013-01-07
Volume
104
Issue
4
Pages
317-323
ISSN
  • 0042-9007
  • 1423-0410
Cited by
92
References
0
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Capillary versus venous haemoglobin determination in the assessment of healthy blood donors. https://app.cochat.ai/papers/10.1111/vox.12006
The paper
Patel, A. J., Wesley, R., Leitman, S. F., & Bryant, B. J. (2013). Capillary versus venous haemoglobin determination in the assessment of healthy blood donors. Vox Sanguinis. https://doi.org/10.1111/vox.12006

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.