CoChat

First quantification of alpha‐Gal epitope in current glutaraldehyde‐fixed heart valve bioprostheses

Naso, Filippo, Gandaglia, Alessandro, Bottio, Tomaso, Tarzia, Vincenzo, Nottle, Mark B., d'Apice, Anthony J. F., Cowan, Peter J., Cozzi, Emmanuele, Galli, Cesare, Lagutina, Irina, Lazzari, Giovanna, Iop, Laura, Spina, Michele, Gerosa, Gino · 2013 · Xenotransplantation
Cited by 122

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background: Glutaraldehyde fixation does not guarantee complete tissue biocompatibility in current clinical bioprosthetic heart valves (BHV s). Particularly, circulating anti‐α G al human antibodies increase significantly from just 10 days after a BHV implantation. The inactivation of such epitope should be mandatory to meet the requirements for a perspectively safe clinical application; nevertheless, its quantitative assessment in commercially available BHV s has never been carried out. Methods: In this investigation, seven different models of BHV s were tested. The number of epitopes was determined with reference to a standard α G al source by an ELISA test. The presence of xenoantigen was subsequently confirmed by immunofluorescence analysis. Porcine tissue, knockout for the α G al epitopes, was used as negative control. Results: E pic™ valve was the only model among those tested, in which the α G al antigen appeared to be completely shielded. Composite T rifecta™ valve exhibited conflicting results: cusps of bovine pericardial tissue were devoid of reactive α G al epitopes, while the stent cover strip of porcine pericardium still maintained 30% of active antigens originally present in native tissue. All other tested BHV s express an α G al amount not significantly different from that exhibited by porcine M osaic® valve (5.2 ± 0.6 × 10 10 each 10 mg of tissue). Conclusions: For the first time, the quantitative evaluation of the α G al epitope in heart valve bioprostheses, already in clinical practice for about 40 yrs, was finally determined. Such quantification might provide indications of biocompatibility relevant for the selection of bioprosthetic devices and an increase in the confidence of the patient. It might become a major quality control tool in the production and redirection of future investigation in the quest for α G al‐free long‐lasting substitutes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/xen.12044

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 122

Metadata

Authors
Naso, F., Gandaglia, A., Bottio, T., Tarzia, V., Nottle, M. B., d'Apice, A. J. F., Cowan, P. J., Cozzi, E., Galli, C., Lagutina, I., Lazzari, G., Iop, L., Spina, M., & Gerosa, G.
Venue
Xenotransplantation
Publisher
Wiley
Published
2013-07
Volume
20
Issue
4
Pages
252-261
ISSN
  • 0908-665X (ISSN-L)
  • 1399-3089
OpenAlex
W2098252984
Cited by
122
References
1
FWCI
9.58
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.