Physiological mechanisms dissociating pulmonary CO2 and O2 exchange dynamics during exercise in humans
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
During moderate exercise (below the lactate threshold, θ L), muscle CO 2 production ( ) kinetics are monoexponential, with a time constant (τ) similar to that of O 2 consumption. Following a delay incorporating the muscle–lung vascular transit time, is expressed at the lungs ( ) with an appreciably longer τ, reflecting the influence of intervening high‐capacitance CO 2 stores. Above θ L, kinetics become complex, resulting from the conflation of the differing rates of HCO 3− breakdown and degrees of compensatory hyperventilation with that of the underlying aerobic component. During incremental exercise, the increased rate of relative to pulmonary O 2 uptake ( ) can be used to quantify θ L validly if aerobic and hyperventilatory sources can be ruled out, i.e. θ L is then attributable to the decrease in muscle and blood [HCO 3−]. In many cases, however, very rapid incrementation of work rate and/or prior depletion of CO 2 stores (by volitional or anticipatory hyperventilation) can yield a ‘false positive’ non‐invasive estimation of θ L (‘pseudo‐threshold’) resulting from a slowing of the rate of wash‐in of transient CO 2 stores.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new method for detecting anaerobic threshold by gas exchange
Beaver, W. L., Wasserman, K., & Whipp, B. J. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.6.2020 · Cited by 4,103
Self-citationCoupling of external to cellular respiration during exercise: the wisdom of the body revisited
Wasserman, K. (1994) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1994.266.4.e519 · Cited by 121 · cited 6×
“This can be convincingly justified using ventilatory and pulmonary gas exchange criteria (Whipp et al. 1986; Wasserman, 1994).”
BackgroundMethodInfluential
Cited by
Measurement of the maximum oxygen uptake V̇ o 2max : V̇ o 2peak is no longer acceptable
Poole, D. C., & Jones, A. M. (2017) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01063.2016 · Cited by 533
Levett, D. Z. H., Jack, S., Swart, M., Carlisle, J., Wilson, J., Snowden, C., Riley, M., Danjoux, G., Ward, S. A., Older, P., et al. (2018) · British Journal of Anaesthesia · doi:10.1016/j.bja.2017.10.020 · Cited by 466
Validity of criteria for establishing maximal O2 uptake during ramp exercise tests
Poole, D. C., Wilkerson, D. P., & Jones, A. M. (2008) · European Journal of Applied Physiology · doi:10.1007/s00421-007-0596-3 · Cited by 417
Exercise: Kinetic Considerations for Gas Exchange
Rossiter, H. B. (2010) · Comprehensive Physiology · doi:10.1002/cphy.c090010 · Cited by 231
Martinez, N., Kilpatrick, M. W., Salomon, K., Jung, M. E., & Little, J. P. (2015) · Journal of Sport and Exercise Psychology · doi:10.1123/jsep.2014-0212 · Cited by 200
“Ventilatory threshold was identified through visual inspection of ventilatory equivalents for oxygen and carbon dioxide (Whipp, 2007).”
Method
Metadata
- Authors
- Whipp, B. J.
- Venue
- Experimental Physiology
- Publisher
- Wiley
- Published
- 2007-03
- Volume
- 92
- Issue
- 2
- Pages
- 347-355
- ISSN
- 0958-0670 (ISSN-L)
- 1469-445X
- OpenAlex
- W1597486735
- Cited by
- 95
- References
- 2
- FWCI
- 3.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Physiological mechanisms dissociating pulmonary CO2 and O2 exchange dynamics during exercise in humans. https://app.cochat.ai/papers/10.1113/expphysiol.2006.034363
- The paper
- Whipp, B. J. (2007). Physiological mechanisms dissociating pulmonary CO2 and O2 exchange dynamics during exercise in humans. Experimental Physiology. https://doi.org/10.1113/expphysiol.2006.034363
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.