CoChat

Breath‐by‐breath pulmonary O2 uptake kinetics: effect of data processing on confidence in estimating model parameters

Open access
Keir, Daniel A., Murias, Juan M., Paterson, Donald H., Kowalchuk, John M. · 2014 · Experimental Physiology
Cited by 97

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

New Findings: What is the central question of this study? In groups of young and older adults, we investigated whether techniques used as common practice for processing breath‐by‐breath pulmonary O 2 uptake data from repeated step transitions in work rate into the moderate‐intensity exercise domain influence the model parameter estimations and confidence of describing the phase II pulmonary O 2 uptake response. What is the main finding and its importance? Results demonstrate that regardless of age group, during transitions into the moderate‐intensity exercise domain, techniques for processing individual transitions did not affect parameter estimates describing the phase II pulmonary O 2 uptake response; however, the confidence in the parameter estimation could be improved by the technique used to process individual trials. To improve the signal‐to‐noise ratio of breath‐by‐breath pulmonary O 2 uptake () data, it is common practice to perform multiple step transitions, which are subsequently processed to yield an ensemble‐averaged profile. The effect of different data‐processing techniques on phase II kinetic parameter estimates ( amplitude, time delay and phase II time constant (τ)] and model confidence [95% confidence interval (CI 95)] was examined. Young (n = 9) and older men (n = 9) performed four step transitions from a 20 W baseline to a work rate corresponding to 90% of their estimated lactate threshold on a cycle ergometer. Breath‐by‐breath was measured using mass spectrometry and volume turbine. Mono‐exponential kinetic modelling of phase II data was performed on data processed using the following techniques: (A) raw data (trials time aligned, breaths of all trials combined and sorted in time); (B) raw data plus interpolation (trials time aligned, combined, sorted and linearly interpolated to second by second); (C) raw data plus interpolation plus 5 s bin averaged; (D) individual trial interpolation plus ensemble averaged [trials time aligned, linearly interpolated to second by second (technique 1; points joined by straight‐line segments), ensemble averaged]; (E) ‘D’ plus 5 s bin averaged; (F) individual trial interpolation plus ensemble averaged [trials time aligned, linearly interpolated to second by second (technique 2; points copied until subsequent point appears), ensemble averaged]; and (G) ‘F’ plus 5 s bin averaged. All of the model parameters were unaffected by data‐processing technique; however, the CI 95 for τ in condition ‘D’ (4 s) was lower (P < 0.05) than the CI 95 reported for all other conditions (5–10 s). Data‐processing technique had no effect on parameter estimates of the phase II response. However, the narrowest interval for CI 95 occurred when individual trials were linearly interpolated and ensemble averaged.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/expphysiol.2014.080812

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 97

Metadata

Authors
Keir, D. A., Murias, J. M., Paterson, D. H., & Kowalchuk, J. M.
Venue
Experimental Physiology
Publisher
Wiley
Published
2014-10-08
Volume
99
Issue
11
Pages
1511-1522
ISSN
  • 0958-0670 (ISSN-L)
  • 1469-445X
OpenAlex
W1502576283
Cited by
97
References
2
FWCI
12.41
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.