Breath‐by‐breath pulmonary O2 uptake kinetics: effect of data processing on confidence in estimating model parameters
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
New Findings: What is the central question of this study? In groups of young and older adults, we investigated whether techniques used as common practice for processing breath‐by‐breath pulmonary O 2 uptake data from repeated step transitions in work rate into the moderate‐intensity exercise domain influence the model parameter estimations and confidence of describing the phase II pulmonary O 2 uptake response. What is the main finding and its importance? Results demonstrate that regardless of age group, during transitions into the moderate‐intensity exercise domain, techniques for processing individual transitions did not affect parameter estimates describing the phase II pulmonary O 2 uptake response; however, the confidence in the parameter estimation could be improved by the technique used to process individual trials. To improve the signal‐to‐noise ratio of breath‐by‐breath pulmonary O 2 uptake () data, it is common practice to perform multiple step transitions, which are subsequently processed to yield an ensemble‐averaged profile. The effect of different data‐processing techniques on phase II kinetic parameter estimates ( amplitude, time delay and phase II time constant (τ)] and model confidence [95% confidence interval (CI 95)] was examined. Young (n = 9) and older men (n = 9) performed four step transitions from a 20 W baseline to a work rate corresponding to 90% of their estimated lactate threshold on a cycle ergometer. Breath‐by‐breath was measured using mass spectrometry and volume turbine. Mono‐exponential kinetic modelling of phase II data was performed on data processed using the following techniques: (A) raw data (trials time aligned, breaths of all trials combined and sorted in time); (B) raw data plus interpolation (trials time aligned, combined, sorted and linearly interpolated to second by second); (C) raw data plus interpolation plus 5 s bin averaged; (D) individual trial interpolation plus ensemble averaged [trials time aligned, linearly interpolated to second by second (technique 1; points joined by straight‐line segments), ensemble averaged]; (E) ‘D’ plus 5 s bin averaged; (F) individual trial interpolation plus ensemble averaged [trials time aligned, linearly interpolated to second by second (technique 2; points copied until subsequent point appears), ensemble averaged]; and (G) ‘F’ plus 5 s bin averaged. All of the model parameters were unaffected by data‐processing technique; however, the CI 95 for τ in condition ‘D’ (4 s) was lower (P < 0.05) than the CI 95 reported for all other conditions (5–10 s). Data‐processing technique had no effect on parameter estimates of the phase II response. However, the narrowest interval for CI 95 occurred when individual trials were linearly interpolated and ensemble averaged.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new method for detecting anaerobic threshold by gas exchange
Beaver, W. L., Wasserman, K., & Whipp, B. J. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.6.2020 · Cited by 4,103
Muscle O2 uptake kinetics in humans: implications for metabolic control
Grassi, B., Poole, D. C., Richardson, R. S., Knight, D. R., Erickson, B. K., & Wagner, P. D. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.80.3.988 · Cited by 561
Cited by
Exercise Intensity Thresholds: Identifying the Boundaries of Sustainable Performance
KEIR, D. A., FONTANA, F. Y., ROBERTSON, T. C., MURIAS, J. M., PATERSON, D. H., KOWALCHUK, J. M., & POGLIAGHI, S. (2015) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000613 · Cited by 205
Self-citationIdentification of Non-Invasive Exercise Thresholds: Methods, Strategies, and an Online App
Keir, D. A., Iannetta, D., Mattioni Maturana, F., Kowalchuk, J. M., & Murias, J. M. (2022) · Sports Medicine · doi:10.1007/s40279-021-01581-z · Cited by 193
Self-citationJamnick, N. A., Botella, J., Pyne, D. B., & Bishop, D. J. (2018) · PLOS ONE · doi:10.1371/journal.pone.0199794 · Cited by 178
“The data was interpolated on a second-by-second basis and averaged into 5- and 30-s bins [44, 45].”
MethodValidity of the Stryd power meter in measuring running parameters at submaximal speeds
Imbach, F., Candau, R., Chailan, R., & Perrey, S. (2020) · Sports · doi:10.3390/sports8070103 · Cited by 72
Iannetta, D., Qahtani, A., Mattioni Maturana, F., & Murias, J. M. (2017) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2017.01.237 · Cited by 48
Self-citation
Metadata
- Authors
- Keir, D. A., Murias, J. M., Paterson, D. H., & Kowalchuk, J. M.
- Venue
- Experimental Physiology
- Publisher
- Wiley
- Published
- 2014-10-08
- Volume
- 99
- Issue
- 11
- Pages
- 1511-1522
- ISSN
- 0958-0670 (ISSN-L)
- 1469-445X
- OpenAlex
- W1502576283
- Cited by
- 97
- References
- 2
- FWCI
- 12.41
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.