Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 606

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Electrophysiological evidence for the existence of orientation and size detectors in the human visual system

Open access
Campbell, F. W., Maffei, L.·1970·The Journal of Physiology

Abstract

1. The evoked potential in response to a grating alternating in phase at 8 c/s was recorded as a function of contrast from the occiput of man. 2. It was found that a linear relation exists between the log. of contrast and the amplitude of the evoked potential. 3. Extrapolation to zero amplitude voltage of the regression line between the amplitude of the evoked potential and log. contrast predicts the psychophysical threshold. This law was found to hold over the wide range of spatial frequencies tested. 4. Below 3 c/deg the results are best fitted with two regression lines; one of these is generated from the foveal and the other from the parafoveal representation in the cortex. 5. The slope of the regression lines was found to be almost independent of either the spatial frequency or the area of the stimulus grating. 6. The slope of the regression lines could be markedly increased by using as a stimulus either two different spatial frequencies, or two different orientations, presented simultaneously. 7. Using the evoked potential the selectivity to orientation was found to be so high that a channel was not influenced by another orientation 15° away. 8. The channels selectively sensitive to spatial frequency were highly selective and were not influenced by another spatial frequency one octave removed in spatial frequency. 9. It is concluded that in man there exist neurones highly selective to both orientation and spatial frequency.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1970.sp009085

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 606

Metadata

Authors
Campbell, F. W., & Maffei, L.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1970-05
Volume
207
Issue
3
Pages
635-652
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2053570064
Cited by
606
References
2
FWCI
30.17
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electrophysiological evidence for the existence of orientation and size detectors in the human visual system. https://app.cochat.ai/papers/10.1113/jphysiol.1970.sp009085
The paper
Campbell, F. W., & Maffei, L. (1970). Electrophysiological evidence for the existence of orientation and size detectors in the human visual system. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1970.sp009085

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.