The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
The effects of load and force on tremor at the normal human elbow joint
Open accessAbstract
1. Spontaneous flexion‐extension tremor of the elbow was recorded in normal human subjects while they exerted a flexing force against different loads. 2. Increases in the flexing force up to ½ or ¾ of the subject's maximum were accompanied by increases in the amplitude of the tremor. A further increase to very large forces was associated with a decrease in tremor. 3. When the subject flexed against a spring, the frequency of the tremor was related to the properties of the spring; with increasingly stiff springs the tremor frequency increased up to about 12 Hz. With the stiffest springs, however, the tremor became irregular and very small in amplitude. 4. Weights added to the limb at the wrist reduced the frequency of tremor. 5. By using appropriate combinations of spring and mass, the principal tremor frequency could be adjusted between 2 and 12 Hz, higher in some subjects. Within this range the frequency 2 was approximately proportional to the spring stiffness/mass, just as it is in a spring‐mass system, though the forearm provided some of this mass, and some of the spring‐like resistance was in the flexor muscles. 6. When by suitable loading the tremor frequency was brought between 8 and 12 Hz, and the subject forcibly flexed his elbow, the tremor became regular and large in amplitude. This was a form of limited instability in the stretch reflex which arose because a powerful reflex response to extension of the elbow acted back on the flexor muscles after a delay. 7. When the limb was so loaded that its natural frequency was outside this 8–12 Hz range, it behaved as a filter, and in response to any disturbing noise it oscillated mainly at frequencies close to the natural frequencies of either the mechanical system or the stretch reflex. 8. This filtering function of the limb with its stretch reflex probably plays an important part in the control of normal movement and tremor. 9. The large flexing forces that were here associated with vigorous tremor normally occur when a limb supports a large mass. Such a mass would give the mechanical system within the limb a low natural frequency; inconveniently large oscillations in the 8–12 Hz range would therefore seldom occur.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The low weight of these IMUs, around 40 g, makes them an optimal solution for our application, as tremor would change its characteristics if a larger mass were attached to the limbs [7].”
From Real-Time Estimation of Pathological Tremor Parameters from Gyroscope Data (2010) · cites this paper as [7]
In the citing paper
“It is based on the fact that most types of tremors change their characteristics (amplitude and frequency) when the apparent limb impedance is modified, for example, applying a force or adding a mass [6–8].”
From Real-Time Estimation of Pathological Tremor Parameters from Gyroscope Data (2010) · cites this paper as [7]
In the citing paper
“However, it has been shown by several researchers that loading of the tremorous body part (externally or internally) can cause changes to the tremor properties, such as the amplitude and frequency (Joyce and Rack, 1974; Rack and Ross, 1986; Aisen et al., 1993; Héroux et al., 2009).”
From Voluntary-Driven Elbow Orthosis with Speed-Controlled Tremor Suppression (2016) · cites this paper as Joyce and Rack, 1974
Citations
Cites
Observations on the control of stepping and hopping movements in man
Jones, G. M., & Watt, D. G. D. (1971) · The Journal of Physiology · doi:10.1113/jphysiol.1971.sp009684 · Cited by 577
Lippold, O. C. J. (1970) · The Journal of Physiology · doi:10.1113/jphysiol.1970.sp009018 · Cited by 286
NERVOUS GRADATION OF MUSCULAR CONTRACTION
HAMMOND, P. H., MERTON, P. A., & SUTTON, G. G. (1956) · British Medical Bulletin · doi:10.1093/oxfordjournals.bmb.a069553 · Cited by 224
Mechanical factors in human tremor frequency
Stiles, R. N., & Randall, J. E. (1967) · Journal of Applied Physiology · doi:10.1152/jappl.1967.23.3.324 · Cited by 191
An analysis of the frequencies of finger tremor in healthy subjects
Halliday, A. M., & Redfearn, J. W. T. (1956) · The Journal of Physiology · doi:10.1113/jphysiol.1956.sp005668 · Cited by 175
Joyce, G. C., Rack, P. M. H., & Ross, H. F. (1974) · The Journal of Physiology · doi:10.1113/jphysiol.1974.sp010614 · Cited by 152
Self-citationMarshall, J., & Walsh, E. G. (1956) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.19.4.260 · Cited by 131
Relationship between forearm tremor and the biceps electromyogram
Fox, J. R., & Randall, J. E. (1970) · Journal of Applied Physiology · doi:10.1152/jappl.1970.29.1.103 · Cited by 95
The significance of grouping of motor unit activity
Taylor, A. (1962) · The Journal of Physiology · doi:10.1113/jphysiol.1962.sp006930 · Cited by 88
The variation of hand tremor with force in healthy subjects
Sutton, G. G., & Sykes, K. (1967) · The Journal of Physiology · doi:10.1113/jphysiol.1967.sp008276 · Cited by 72
EFFECT OF DEAFFERENTATION ON HUMAN PHYSIOLOGICAL TREMOR
MARSDEN, C. D., Meadows, J. C., Lange, G. W., & Watson, R. S. (1967) · The Lancet · doi:10.1016/s0140-6736(67)90977-4 · Cited by 63
Sutton, G. G., & Sykes, K. (1967) · The Journal of Physiology · doi:10.1113/jphysiol.1967.sp008208 · Cited by 62
Variations in human physiological finger tremor, with particular reference to changes with age
MARSDEN, C. D., Meadows, J. C., Lange, G. W., & Watson, R. S. (1969) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(69)90170-9 · Cited by 59
The frequency and pattern of normal tremor
Yap, C.-B., & Boshes, B. (1967) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(67)90221-0 · Cited by 40
The effect of force on elbow tremor.
Gc, J., & Pm, R. (1971) · PubMed · Cited by 3
Cited by
Aging, muscle activity, and balance control: physiologic changes associated with balance impairment
Laughton, C. A., Slavin, M., Katdare, K., Nolan, L., Bean, J. F., Kerrigan, D. C., Phillips, E., Lipsitz, L. A., & Collins, J. J. (2003) · Gait & Posture · doi:10.1016/s0966-6362(02)00200-x · Cited by 588
“Age-related increases in muscle activity may be maladaptive with respect to short-term posture control as the force output of skeletal muscle contains noise-like fluctuations [9], which increase with increased muscle activity [10,11].”
BackgroundWinters, J. M., & Stark, L. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325498 · Cited by 526
Physiological and pathological tremors and rhythmic central motor control
McAuley, J. H. (2000) · Brain · doi:10.1093/brain/123.8.1545 · Cited by 509
“However, other studies using such experimental manipulations (Joyce and Rack, 1974; Matthews and Muir,Higher amplitude tremors 1980) revealed a shift in tremor (and EMG) peak, indicatingWhen there is increased tremor amplitude, whether on posture a mechanical or stretch reflex origin.”
BackgroundGalganski, M. E., Fuglevand, A. J., & Enoka, R. M. (1993) · Journal of Neurophysiology · doi:10.1152/jn.1993.69.6.2108 · Cited by 465
Hill-Based Muscle Models: A Systems Engineering Perspective
Winters, J. M. (1990) · Multiple Muscle Systems · doi:10.1007/978-1-4613-9030-5_5 · Cited by 386
Metadata
- Authors
- Joyce, G. C., & Rack, P. M. H.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1974-07
- Volume
- 240
- Issue
- 2
- Pages
- 375-396
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- PMC
- PMC1331021
- OpenAlex
- W1989458918
- Cited by
- 167
- References
- 15
- Citations by year
- 2026: 2 · 2025: 3 · 2024: 1 · 2022: 2 · 2021: 1 · 2020: 2 · 2019: 1 · 2018: 1 · 2017: 2 · 2016: 6 · 2015: 1 · 2014: 6 · 2013: 4 · 2012: 1
- FWCI
- 3.96
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- The Journal of Physiology (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Physical Sciences › Engineering › Biomedical Engineering › Mechanics and Biomechanics Studies
- Keywords
- tremor frequency, tremor amplitude, mass-spring system, natural frequencies, stretch reflex, flexor muscles, tremor filtering, motor control
- MeSH terms
- Adolescent, Adult, Biomechanical Phenomena, Child, Elbow, Physical Exertion, Female, Forearm, Humans, Male, Middle Aged, Muscles, Reflex, Wrist
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.