The effects of load and force on tremor at the normal human elbow joint
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
1. Spontaneous flexion‐extension tremor of the elbow was recorded in normal human subjects while they exerted a flexing force against different loads. 2. Increases in the flexing force up to ½ or ¾ of the subject's maximum were accompanied by increases in the amplitude of the tremor. A further increase to very large forces was associated with a decrease in tremor. 3. When the subject flexed against a spring, the frequency of the tremor was related to the properties of the spring; with increasingly stiff springs the tremor frequency increased up to about 12 Hz. With the stiffest springs, however, the tremor became irregular and very small in amplitude. 4. Weights added to the limb at the wrist reduced the frequency of tremor. 5. By using appropriate combinations of spring and mass, the principal tremor frequency could be adjusted between 2 and 12 Hz, higher in some subjects. Within this range the frequency 2 was approximately proportional to the spring stiffness/mass, just as it is in a spring‐mass system, though the forearm provided some of this mass, and some of the spring‐like resistance was in the flexor muscles. 6. When by suitable loading the tremor frequency was brought between 8 and 12 Hz, and the subject forcibly flexed his elbow, the tremor became regular and large in amplitude. This was a form of limited instability in the stretch reflex which arose because a powerful reflex response to extension of the elbow acted back on the flexor muscles after a delay. 7. When the limb was so loaded that its natural frequency was outside this 8–12 Hz range, it behaved as a filter, and in response to any disturbing noise it oscillated mainly at frequencies close to the natural frequencies of either the mechanical system or the stretch reflex. 8. This filtering function of the limb with its stretch reflex probably plays an important part in the control of normal movement and tremor. 9. The large flexing forces that were here associated with vigorous tremor normally occur when a limb supports a large mass. Such a mass would give the mechanical system within the limb a low natural frequency; inconveniently large oscillations in the 8–12 Hz range would therefore seldom occur.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The low weight of these IMUs, around 40 g, makes them an optimal solution for our application, as tremor would change its characteristics if a larger mass were attached to the limbs [7].”
From Real-Time Estimation of Pathological Tremor Parameters from Gyroscope Data (2010) · cites this paper as [7]
In the citing paper
“It is based on the fact that most types of tremors change their characteristics (amplitude and frequency) when the apparent limb impedance is modified, for example, applying a force or adding a mass [6–8].”
From Real-Time Estimation of Pathological Tremor Parameters from Gyroscope Data (2010) · cites this paper as [7]
In the citing paper
“However, it has been shown by several researchers that loading of the tremorous body part (externally or internally) can cause changes to the tremor properties, such as the amplitude and frequency (Joyce and Rack, 1974; Rack and Ross, 1986; Aisen et al., 1993; Héroux et al., 2009).”
From Voluntary-Driven Elbow Orthosis with Speed-Controlled Tremor Suppression (2016) · cites this paper as Joyce and Rack, 1974
Citations
Cites
Observations on the control of stepping and hopping movements in man
Jones, G. M., & Watt, D. G. D. (1971) · The Journal of Physiology · doi:10.1113/jphysiol.1971.sp009684 · Cited by 577
Lippold, O. C. J. (1970) · The Journal of Physiology · doi:10.1113/jphysiol.1970.sp009018 · Cited by 286
NERVOUS GRADATION OF MUSCULAR CONTRACTION
HAMMOND, P. H., MERTON, P. A., & SUTTON, G. G. (1956) · British Medical Bulletin · doi:10.1093/oxfordjournals.bmb.a069553 · Cited by 224
Mechanical factors in human tremor frequency
Stiles, R. N., & Randall, J. E. (1967) · Journal of Applied Physiology · doi:10.1152/jappl.1967.23.3.324 · Cited by 191
An analysis of the frequencies of finger tremor in healthy subjects
Halliday, A. M., & Redfearn, J. W. T. (1956) · The Journal of Physiology · doi:10.1113/jphysiol.1956.sp005668 · Cited by 175
Joyce, G. C., Rack, P. M. H., & Ross, H. F. (1974) · The Journal of Physiology · doi:10.1113/jphysiol.1974.sp010614 · Cited by 152
Self-citationMarshall, J., & Walsh, E. G. (1956) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.19.4.260 · Cited by 131
Relationship between forearm tremor and the biceps electromyogram
Fox, J. R., & Randall, J. E. (1970) · Journal of Applied Physiology · doi:10.1152/jappl.1970.29.1.103 · Cited by 95
The significance of grouping of motor unit activity
Taylor, A. (1962) · The Journal of Physiology · doi:10.1113/jphysiol.1962.sp006930 · Cited by 88
The variation of hand tremor with force in healthy subjects
Sutton, G. G., & Sykes, K. (1967) · The Journal of Physiology · doi:10.1113/jphysiol.1967.sp008276 · Cited by 70
Cited by
Aging, muscle activity, and balance control: physiologic changes associated with balance impairment
Laughton, C. A., Slavin, M., Katdare, K., Nolan, L., Bean, J. F., Kerrigan, D. C., Phillips, E., Lipsitz, L. A., & Collins, J. J. (2003) · Gait & Posture · doi:10.1016/s0966-6362(02)00200-x · Cited by 588
“Age-related increases in muscle activity may be maladaptive with respect to short-term posture control as the force output of skeletal muscle contains noise-like fluctuations [9], which increase with increased muscle activity [10,11].”
BackgroundWinters, J. M., & Stark, L. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325498 · Cited by 526
Physiological and pathological tremors and rhythmic central motor control
McAuley, J. H. (2000) · Brain · doi:10.1093/brain/123.8.1545 · Cited by 509
“However, other studies using such experimental manipulations (Joyce and Rack, 1974; Matthews and Muir,Higher amplitude tremors 1980) revealed a shift in tremor (and EMG) peak, indicatingWhen there is increased tremor amplitude, whether on posture a mechanical or stretch reflex origin.”
BackgroundGalganski, M. E., Fuglevand, A. J., & Enoka, R. M. (1993) · Journal of Neurophysiology · doi:10.1152/jn.1993.69.6.2108 · Cited by 465
Hill-Based Muscle Models: A Systems Engineering Perspective
Winters, J. M. (1990) · Multiple Muscle Systems · doi:10.1007/978-1-4613-9030-5_5 · Cited by 386
The effects of visual input on open-loop and closed-loop postural control mechanisms
Collins, J. J., & De Luca, C. J. (1995) · Experimental Brain Research · doi:10.1007/bf00241972 · Cited by 363
“…Luca et al. 1982) and since the average amplitude of these noise-like fluctuations decreases as the amount of force produced by a muscle decreases (Joyce and Rack 1974), the above postural control strategy would lead to lower average levels of short-term postural sway and smaller eyes-open…”
BackgroundMatthews, P. B. (1986) · The Journal of Physiology · doi:10.1113/jphysiol.1986.sp016066 · Cited by 348
Age-related changes in open-loop and closed-loop postural control mechanisms
Collins, J. J., De Luca, C. J., Burrows, A., & Lipsitz, L. A. (1995) · Experimental Brain Research · doi:10.1007/bf00231982 · Cited by 345
Servo action in the human thumb.
Marsden, C. D., Merton, P. A., & Morton, H. B. (1976) · The Journal of Physiology · doi:10.1113/jphysiol.1976.sp011354 · Cited by 314
McAuley, J. H., Rothwell, J. C., & Marsden, C. D. (1997) · Experimental Brain Research · doi:10.1007/pl00005662 · Cited by 285
Winters, J. M., & Stark, L. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90249-7 · Cited by 283
A wireless haptic interface for programmable patterns of touch across large areas of the skin
Jung, Y. H., Yoo, J.-Y., Vázquez-Guardado, A., Kim, J.-H., Kim, J.-T., Luan, H., Park, M., Lim, J., Shin, H.-S., Su, C.-J., et al. (2022) · Nature Electronics · doi:10.1038/s41928-022-00765-3 · Cited by 263
Tremor and other oscillations in neuromuscular systems
Stein, R. B., & Oĝuztöreli, M. N. (1976) · Biological Cybernetics · doi:10.1007/bf00365525 · Cited by 264
Effects of body lean and visual information on the equilibrium maintenance during stance
Duarte, M., & Zatsiorsky, V. M. (2002) · Experimental Brain Research · doi:10.1007/s00221-002-1154-1 · Cited by 260
“But for higher activations levels, muscles present higher variability in the force output (Joyce and Rack 1974), which would generate more instability in the posture control.”
Muscle models: What is gained and what is lost by varying model complexity
Winters, J. M., & Stark, L. (1987) · Biological Cybernetics · doi:10.1007/bf00318375 · Cited by 240
Lee, R. G., & Stein, R. B. (1981) · Annals of Neurology · doi:10.1002/ana.410100606 · Cited by 205
Gandevia, S. C., & McCloskey, D. I. (1977) · The Journal of Physiology · doi:10.1113/jphysiol.1977.sp012066 · Cited by 203
Coactivation of the antagonist muscle does not covary with steadiness in old adults
Burnett, R. A., Laidlaw, D. H., & Enoka, R. M. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.89.1.61 · Cited by 157
“form isometric contractions, either against a rigid restraint or an elastic load, the fluctuations in force are characterized by a peak in the power density spectrum at 8–12 Hz (1, 5, 22, 28) and possibly at 20 and 40 Hz (29).”
BackgroundJoyce, G. C., Rack, P. M. H., & Ross, H. F. (1974) · The Journal of Physiology · doi:10.1113/jphysiol.1974.sp010614 · Cited by 152
Self-citationOrigins of normal and pathological tremor
Marsden, C. D. (1984) · Movement Disorders: Tremor · doi:10.1007/978-1-349-06757-2_4 · Cited by 142
A study of the muscle force waveform using a population stochastic model of skeletal muscle
Christakos, C. N. (1982) · Biological Cybernetics · doi:10.1007/bf00317969 · Cited by 143
Parkinsonism in neuroleptic-naive schizophrenic patients
Caligiuri, M. P., Lohr, J. B., & Jeste, D. V. (1993) · American Journal of Psychiatry · doi:10.1176/ajp.150.9.1343 · Cited by 149
Physiologic tremor and microsurgery
Harwell, R. C., & Ferguson, R. L. (1983) · Microsurgery · doi:10.1002/micr.1920040310 · Cited by 131
Physiological tremor enhanced by manoeuvres affecting the segmental stretch reflex.
Young, R. R., & Hagbarth, K. E. (1980) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.43.3.248 · Cited by 127
Dietz, V., Bischofberger, E., Wita, C. W., & Freund, H. (1976) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(76)90183-8 · Cited by 117
Goodwin, G. M., Hoffman, D. S., & Luschei, E. S. (1978) · The Journal of Physiology · doi:10.1113/jphysiol.1978.sp012332 · Cited by 113
“Thus, very high reflex stiffness as described here and by Joyce et al. (1974) may result from amplification by motoneurones specifically of sinusoidal stimuli; the high stiffness may not have a more general functional significance.”
BackgroundResultInfluentialGoodwin, G. M., Hulliger, M., & Matthews, P. B. C. (1975) · The Journal of Physiology · doi:10.1113/jphysiol.1975.sp011186 · Cited by 108
Real-Time Estimation of Pathological Tremor Parameters from Gyroscope Data
Gallego, J., Rocon, E., Roa, J. O., Moreno, J., & Pons, J. L. (2010) · Sensors · doi:10.3390/s100302129 · Cited by 107
“The low weight of these IMUs, around 40 g, makes them an optimal solution for our application, as tremor would change its characteristics if a larger mass were attached to the limbs [7].”
BackgroundSchwestka‐Polly, R., Windhorst, U., & Schaumberg, R. (1981) · Experimental Brain Research · doi:10.1007/bf00238807 · Cited by 107
Regulation of the firing pattern of single motor units.
Andreassen, S., & Rosenfalck, A. M. (1980) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.43.10.897 · Cited by 111
Short-term effects of intrathecal baclofen in spasticity
Latash, M. L., Penn, R. D., Corcos, D. M., & Gottlieb, G. L. (1989) · Experimental Neurology · doi:10.1016/0014-4886(89)90078-2 · Cited by 100
Oscillation of the human ankle joint in response to applied sinusoidal torque on the foot
Agarwal, G. C., & Gottlieb, G. L. (1977) · The Journal of Physiology · doi:10.1113/jphysiol.1977.sp011852 · Cited by 112
Cooker, H. S., Larson, C. R., & Luschei, E. S. (1980) · The Journal of Physiology · doi:10.1113/jphysiol.1980.sp013462 · Cited by 99
Biomechanical study of the final push‐pull in archery
Leroyer, P., Hoecke, J. V., & Helal, J.-N. (1993) · Journal of Sports Sciences · doi:10.1080/02640419308729965 · Cited by 105
Limitations of Somatosensory Feedback in Control of Posture and Movement
Rack, P. M. H. (1981) · Comprehensive physiology · doi:10.1002/cphy.cp010207 · Cited by 119
Self-citationLimitations in the servo-regulation of soleus muscle stiffness in premammillary cats
Hoffer, J. A., & Andreassen, S. (1981) · Palgrave Macmillan UK eBooks · doi:10.1007/978-1-349-06022-1_34 · Cited by 96
Stein, R. B., & Lee, R. G. (1981) · Comprehensive Physiology · doi:10.1002/cphy.cp010209 · Cited by 93
Koehler, W., & Windhorst, U. (1981) · Biological Cybernetics · doi:10.1007/bf00326681 · Cited by 94
Single site electromyograph amplitude estimation
Clancy, E. A., & Hogan, N. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.284927 · Cited by 91
Common modulation of motor unit pairs during slow wrist movement in man
Kakuda, N., Nagaoka, M., & Wessberg, J. (1999) · The Journal of Physiology · doi:10.1111/j.1469-7793.1999.00929.x · Cited by 90
“This idea has been comprehensively investigated for the phenomenon of physiological tremor during position holding (Lippold, 1970; Joyce & Rack, 1974; Elble & Randall, 1976; Burne et al. 1984).”
BackgroundHuman Balance out of Equilibrium: Nonequilibrium Statistical Mechanics in Posture Control
Lauk, M., Chow, C. C., Pavlik, A. E., & Collins, J. J. (1998) · Physical Review Letters · doi:10.1103/physrevlett.80.413 · Cited by 75
(1987) · PubMed · Cited by 75
Pulsatile motor output in human finger movements is not dependent on the stretch reflex.
Wessberg, J., & Vallbo, Å. B. (1996) · The Journal of Physiology · doi:10.1113/jphysiol.1996.sp021432 · Cited by 78
Comparison of electromyogram spectra with force spectra during human elbow tremor.
Matthews, P. B., & Muir, R. B. (1980) · The Journal of Physiology · doi:10.1113/jphysiol.1980.sp013254 · Cited by 70
Adaptative effects of loss of vision on upright undisturbed stance
Rougier, P. R., & Farenc, I. (2000) · Brain Research · doi:10.1016/s0006-8993(00)02357-x · Cited by 67
The amplitude of force variability is correlated in the knee extensor and elbow flexor muscles
Tracy, B., Mehoudar, P. D., & Ortega, J. D. (2006) · Experimental Brain Research · doi:10.1007/s00221-006-0631-3 · Cited by 73
Evidence for a non-orthostatic origin of orthostatic tremor
Boroojerdi, B., Ferbert, A., Foltys, H., Kosinski, C. M., Noth, J., & Schwarz, M. (1999) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.66.3.284 · Cited by 62
A Review on Wearable Technologies for Tremor Suppression
Lora-Millan, J. S., Delgado-Oleas, G., Benito-León, J., & Rocon, E. (2021) · Frontiers in Neurology · doi:10.3389/fneur.2021.700600 · Cited by 62
“In 1974, Joyce and Rack (89) reported the first results of adding force and inertia to physiological tremor.”
BackgroundStretch reflex responses in the human elbow joint during a voluntary movement.
Bennett, D. J. (1994) · The Journal of Physiology · doi:10.1113/jphysiol.1994.sp020026 · Cited by 59
Kouzaki, M., Shinohara, M., Masani, K., & Fukunaga, T. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00418.2004 · Cited by 65
“It had been suggested that physiological tremor is partly due to rhythmic modulation of the activity of several motor units caused by a servo-loop oscillation in the stretch reflex arc as a result of muscle spindle activity (13, 23, 29, 30).”
BackgroundAcoustic myography during voluntary isometric contraction reveals non-propagative lateral vibration
Ouamer, M., Boiteux, M., Petitjean, M., Travens, L., & Salès, A. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00132-3 · Cited by 57
Löscher, W. N., Cresswell, A. G., & Thorstensson, A. (1994) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1994.tb09786.x · Cited by 66
An intrinsic mechanism for the oscillatory contraction of muscle
Akamatsu, N., Hannaford, B., & STARK, L. W. (1986) · Biological Cybernetics · doi:10.1007/bf00336992 · Cited by 58
“Increases in the spring force up to 1/2 or 3/4 of the subject's maximum capability are accompanied by increases in the amplitude of the elbow tremor as reported by Joyce and Rack (1974). In this case the waveform of the tremor is approximately sinusoidal.”
BackgroundInfluentialOptimal digital filtering for tremor suppression
Gonzalez, J. G., Heredia, E. A., Rahman, T., Barner, K. E., & Arce, G. R. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.841338 · Cited by 56
“This problem, which we call thegrosso-fitting problem, has been overcome in the context of tremor suppression by high-pass [15], [31], [41], [42]”
BackgroundMehta, A. R., Brittain, J., & Brown, P. (2014) · Journal of Neuroscience · doi:10.1523/jneurosci.0510-14.2014 · Cited by 62
“Ourdataalsotendtorefutethehypothesisthatphysiological tremor, whether postural or kinetic, is exclusively mediated by peripheral and/or spinal mechanisms (Joyce and Rack, 1974; Lakie et al., 1986, 2012; Vernooij et al., 2013).”
BackgroundResponse of the normal human ankle joint to imposed sinusoidal movements.
Evans, C. M., Fellows, S. J., Rack, P. M. H., Ross, H. F., & Walters, D. K. (1983) · The Journal of Physiology · doi:10.1113/jphysiol.1983.sp014953 · Cited by 52
Self-citationVoluntary-Driven Elbow Orthosis with Speed-Controlled Tremor Suppression
Herrnstadt, G., & Menon, C. (2016) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2016.00029 · Cited by 49
“However, it has been shown by several researchers that loading of the tremorous body part (externally or internally) can cause changes to the tremor properties, such as the amplitude and frequency (Joyce and Rack, 1974; Rack and Ross, 1986; Aisen et al., 1993; Héroux et al., 2009).”
BackgroundMatthews, P. B. C., & Watson, J. D. G. (1981) · The Journal of Physiology · doi:10.1113/jphysiol.1981.sp013985 · Cited by 50
A Quaternion Weighted Fourier Linear Combiner for Modeling Physiological Tremor
Adhikari, K., Tatinati, S., Ang, W. T., Veluvolu, K. C., & Nazarpour, K. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2530564 · Cited by 48
“This phenomenon was corroborated by others [40], [41].”
ResultInstability in human forearm movements studied with feed‐back‐controlled muscle vibration.
Procházka, A., & Trend, P. (1988) · The Journal of Physiology · doi:10.1113/jphysiol.1988.sp017213 · Cited by 49
A nonlinear analysis of the temporal characteristics of handwriting
Longstaff, M. G., & Heath, R. A. (1999) · Human Movement Science · doi:10.1016/s0167-9457(99)00028-7 · Cited by 47
Effect of muscle fatigue on internal model formation and retention during reaching with the arm
Takahashi, C. D., Nemet, D., Rose-Gottron, C. M., Larson, J. K., Cooper, D. M., & Reinkensmeyer, D. J. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00140.2005 · Cited by 51
Eklund, G., Hagbarth, K. E., Hägglund, J. V., & Wallin, E. U. (1982) · The Journal of Physiology · doi:10.1113/jphysiol.1982.sp014177 · Cited by 50
An analysis of oscillations in neuro-muscular systems
guztöreli, M. N. O., & Stein, R. B. (1975) · Journal of Mathematical Biology · doi:10.1007/bf00275922 · Cited by 43
A Dynamic System Model of an Off-Road Cyclist
Wang, E. L., & Hull, M. L. (1997) · Journal of Biomechanical Engineering · doi:10.1115/1.2796088 · Cited by 41
Effect of mental fatigue on induced tremor in human knee extensors
Budini, F., Lowery, M. M., Durbaba, R., & VITO, G. D. (2014) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2014.02.003 · Cited by 49
“…maintaining force fluctuations (hereafter referred to as instability) can be revealed when contracting against a compliant load, such as a spring, and can be attributed to instability of the stretch reflex pathway [Durbaba et al., 2005; Joyce and Rack, 1974; Lippold, 1970; Matthews and Muir, 1980].”
BackgroundCaligiuri, M. P., Lohr, J. B., Bracha, H. S., & Jeste, D. V. (1991) · Biological Psychiatry · doi:10.1016/0006-3223(91)90042-k · Cited by 41
A soft wearable robot for tremor assessment and suppression
Gallego, J. Á., Rocón, E., Ibáñez, J., Dideriksen, J. L., Koutsou, A. D., Paradiso, R., Popović, M. B., Lois, J. M. B., Gianfelici, F., Farina, D., et al. (2011) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2011.5979639 · Cited by 39
“This work relied on the known effects of impedance modulation in tremor, [6], and provided with up to 80 % tremor attenuation in severe cases, without impeding the user to perform functional tasks.”
MethodCollins, J. J., Luca, C. J. D., Pavlik, A. E., Roy, S. H., & Emley, M. (1995) · Experimental Brain Research · doi:10.1007/bf00228026 · Cited by 37
“…(De Luca et al. 1982) and since the mean amplitude of these noise-like fluctuations increases as the amount of force produced by a muscle increases (Joyce and Rack 1974), the above compensatory strategy would lead to larger average levels of short-term postural sway and larger short-term effective…”
BackgroundInfluentialForces generated at the thumb interphalangeal joint during imposed sinusoidal movements
Brown, T., Rack, P. M. H., & Ross, H. F. (1982) · The Journal of Physiology · doi:10.1113/jphysiol.1982.sp014401 · Cited by 41
Self-citationDifferent types of tremor in the human thumb.
Brown, T. I., Rack, P. M., & Ross, H. F. (1982) · The Journal of Physiology · doi:10.1113/jphysiol.1982.sp014404 · Cited by 36
Self-citationLin, D. C., & Rymer, W. Z. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.83.2.652 · Cited by 34
Shooting performance is related to forearm temperature and hand tremor size
Lakie, M., Villagra, F., Bowman, I. H., & Wilby, R. (1995) · Journal of Sports Sciences · doi:10.1080/02640419508732245 · Cited by 42
Physiological tremor in human subjects with X‐linked Kallmann's syndrome and mirror movements
Mayston, M. J., Harrison, L. M., Stephens, J. A., & Farmer, S. F. (2001) · The Journal of Physiology · doi:10.1111/j.1469-7793.2001.0551k.x · Cited by 34
“…and the absence of crossing of spinal latency excitatory reflexes in XKS suggest that oscillations in spinal reflex pathways do not produce significant common modulation of motor unit firing and therefore do not contribute to non-enhanced neurogenic tremor (Lippold, 1970; Joyce & Rack, 1974).”
BackgroundChaudhry, S., Morrissey, D., WOLEDGE, R. C., Bader, D. L., & Screen, H. R. C. (2014) · Journal of Applied Biomechanics · doi:10.1123/jab.2013-0284 · Cited by 31
A Correlation-Based Framework for Evaluating Postural Control Stochastic Dynamics
Hernandez, M. E., Snider, J., Stevenson, C., Cauwenberghs, G., & Howard Poizner, A. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2436344 · Cited by 30
“[49]–[53], consistent with prior work [32].”
Stretch reflex instability compared in three different human muscles
Durbaba, R., Taylor, A. R., Manu, C. A., & Buonajuti, M. (2005) · Experimental Brain Research · doi:10.1007/s00221-004-2165-x · Cited by 36
“Second, there is the possible contribution from the stretch reflex (Lippold 1970; Joyce and Rack 1974; Stein and Oguztöreli 1976; Matthews and Muir 1980).”
BackgroundMethodInfluentialBudini, F., McManus, L. M., Berchicci, M., Menotti, F., Macaluso, A., Russo, F. D., Lowery, M. M., & VITO, G. D. (2014) · PLoS ONE · doi:10.1371/journal.pone.0115012 · Cited by 34
“The greater amplitude of the force oscillations during compliant contractions is consistent with the findings of others [16, 18, 20] and has been attributed to the contribution of the stretch reflex, which enhances the oscillations [28, 17] to the extent that it overwhelms neural mechanisms that would minimize the lim…”
BackgroundResultStability of frequency during long-term recordings of hand tremor
Hefter, H., Hömberg, V., Reiners, K., & Freund, H. (1987) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(87)90007-1 · Cited by 30
THE EFFECT OF MECHANICAL IMPEDANCE ON ABNORMAL INTENTION TREMOR
Adelstein, B. D., & Rosen, M. J. (1981) · Bioengineering · doi:10.1016/b978-0-08-027207-8.50047-3 · Cited by 28
The Dynamics of Voluntary Force Production in Afferented Muscle Influence Involuntary Tremor
Laine, C. M., Nagamori, A., & Valero‐Cuevas, F. J. (2016) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2016.00086 · Cited by 31
“The two mechanisms likely interact, since reflex activity is itself influenced bymuscle/tendon compliance (Rack et al., 1983), limb loading (Joyce and Rack, 1974), contraction history (Gregory et al., 1998), and the temporal dynamics of force production (Xia et al., 2005).”
BackgroundBiomechanical Loading as an Alternative Treatment for Tremor: A Review of Two Approaches
Rocon, E., Gallego, J. A., Belda-Lois, J., Benito-León, J., & Pons, J. L. (2012) · Tremor and Other Hyperkinetic Movements · doi:10.7916/d82z147g · Cited by 37
Damping Actions of the Neuromuscular System With Inertial Loads: Human Flexor Pollicis Longus Muscle
Lin, D. C., & Rymer, W. Z. (2001) · Journal of Neurophysiology · doi:10.1152/jn.2001.85.3.1059 · Cited by 25
Keller, S. R., & Dure, L. S. (2009) · Seminars in Pediatric Neurology · doi:10.1016/j.spen.2009.03.007 · Cited by 26
Burne, J. A., Blanche, T., & Morris, J. J. (2004) · Muscle & Nerve · doi:10.1002/mus.20109 · Cited by 24
Postural control at the human wrist
Chew, J., Gandevia, S. C., & Fitzpatrick, R. C. (2008) · The Journal of Physiology · doi:10.1113/jphysiol.2007.146910 · Cited by 26
Interaction of Tremor and Magnification in a Motor Performance Task With Visual Feedback
Vasilakos, K., Glass, L., & Beuter, A. C. (1998) · Journal of Motor Behavior · doi:10.1080/00222899809601333 · Cited by 23
Entrainment to extinction of physiological tremor by spindle afferent input
Cathers, I., O’Dwyer, N., & Neilson, P. D. (2005) · Experimental Brain Research · doi:10.1007/s00221-005-0258-9 · Cited by 24
“However, when the frequency of the mechanical component of physiological tremor is reduced by increasing the mass loading of the limb (Joyce and Rack 1974; Brown et al. 1982a), a component at 8– 12 Hz remains constant or even shifts to slightly higher frequencies (Elble and Randall 1976, 1978), suggesting that it has…”
BackgroundInfluentialEvaluation of a controlled-energy-dissipation orthosis for tremor suppression
Arnold, A. S., Rosen, M. J., & Aisen, M. L. (1993) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(05)80001-x · Cited by 24
Cussons, P. D., Matthews, P. B. C., & Muir, R. B. (1980) · The Journal of Physiology · doi:10.1113/jphysiol.1980.sp013255 · Cited by 23
Stretch reflex gain in cat triceps surae muscles with compliant loads
Serres, S. J. D., Bennett, D. J., & Stein, R. B. (2002) · The Journal of Physiology · doi:10.1113/jphysiol.2002.027177 · Cited by 20
“When a spring-mass system was used as the external load, the tremor frequency was strongly related to the mechanical properties of the limb-load system (in humans: Joyce & Rack, 1974) or muscle-load system (in decerebrate cats: Nichols et al. 1978).”
MethodA range of different stretch reflex responses in the human thumb
Brown, T., Rack, P. M. H., & Ross, H. F. (1982) · The Journal of Physiology · doi:10.1113/jphysiol.1982.sp014403 · Cited by 23
Self-citationReynolds, R. F., & Lakie, M. (2010) · Journal of Neurophysiology · doi:10.1152/jn.00513.2010 · Cited by 19
Periodontal anaesthesia reduces common 8 Hz input to masseters during isometric biting
Sowman, P. F., Brinkworth, R. S. A., & Türker, K. S. (2005) · Experimental Brain Research · doi:10.1007/s00221-005-0144-5 · Cited by 23
“Other evidence suggests that tremor arises from activity perpetuated in muscle spindle reflex loops causing rhythmic synchronisation of MUs relative to the delay time around the loop (Lippold 1970; Joyce and Rack 1974; Joyce et al. 1974; Matthews and Muir 1980; Jacks et al. 1988; Prochazka and Trend 1988; Cresswell an…”
BackgroundInfluentialParametric analysis of dynamic postural responses
Werness, S. A. S., & Anderson, D. J. (1984) · Biological Cybernetics · doi:10.1007/bf00346137 · Cited by 19
The origins of physiological tremor as deduced from immersions of the finger in various liquids
Takanokura, M., Kokuzawa, N., & Sakamoto, K. (2002) · European Journal of Applied Physiology · doi:10.1007/s00421-002-0677-2 · Cited by 18
“Various researchers have attempted to verify this hypothesis by experiments which have increased the load on the limb segment (Joyce and Rack 1974; Lakie et al. 1986; Hömberg et al. 1987; Sakamoto et al. 1993; Arihara and Sakamoto 1999a).”
BackgroundMethods of time and frequency domain examination of physiological tremor in the human jaw
Sowman, P. F., & Türker, K. S. (2005) · Human Movement Science · doi:10.1016/j.humov.2005.09.003 · Cited by 19
Bioinformatic Approaches Used in Modelling Human Tremor
Mario, M., Giuliana, G., Thomas, L., Dario, F., Lana, P., Silvia, C., Tommaso, D., Juan-Manuel, B.-L., Jose-Luis, P., & Eduardo, R. (2009) · Current Bioinformatics · doi:10.2174/157489309788184747 · Cited by 17
“In some cases, displacement sensors have also been used, such as pressure gauges [21], strain gauges [22-23], optical sensors [24], and more recently digitizing tablets [25-28].”
MethodModification of muscle responses by spinal circuitry
Stein, R. B., & Oguztöreli, M. N. (1984) · Neuroscience · doi:10.1016/0306-4522(84)90226-4 · Cited by 18
Bilateral tremor responses to unilateral loading and fatiguing muscle contractions
Kavanagh, J. J., Cresswell, A. G., Sabapathy, S., & Carroll, T. J. (2013) · Journal of Neurophysiology · doi:10.1152/jn.00228.2013 · Cited by 19
“For EMG frequency-domain analysis, raw EMG data were full-wave rectified and then low-pass filtered at 40 Hz (termed demodulated EMG; Elble and Randall 1976; Fox and Randall 1970; Joyce and Rack 1974; Matthews and Muir 1980).”
BackgroundMethodResult
Metadata
- Authors
- Joyce, G. C., & Rack, P. M. H.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1974-07
- Volume
- 240
- Issue
- 2
- Pages
- 375-396
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- PMC
- PMC1331021
- OpenAlex
- W1989458918
- Cited by
- 167
- References
- 15
- Citations by year
- 2026: 2 · 2025: 3 · 2024: 1 · 2022: 2 · 2021: 1 · 2020: 2 · 2019: 1 · 2018: 1 · 2017: 2 · 2016: 6 · 2015: 1 · 2014: 6 · 2013: 4 · 2012: 1
- FWCI
- 3.96
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- The Journal of Physiology (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Physical Sciences › Engineering › Biomedical Engineering › Mechanics and Biomechanics Studies
- Keywords
- tremor frequency, tremor amplitude, mass-spring system, natural frequencies, stretch reflex, flexor muscles, tremor filtering, motor control
- MeSH terms
- Adolescent, Adult, Biomechanical Phenomena, Child, Elbow, Physical Exertion, Female, Forearm, Humans, Male, Middle Aged, Muscles, Reflex, Wrist
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.