Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 179

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

The control of retinal ganglion cell discharge by receptive field surrounds.

Open access
Enroth‐Cugell, C, Lennie, P · 1975 · The Journal of Physiology

Abstract

1. This paper describes the behaviour of the receptive field surround, and how surround signals combine with those from the centre to generate the discharge of the retinal ganglion cells of the cat. 2. A small test spot is flashed upon the middle of the receptive field of an on‐centre X‐cell, alone, or together with a concentric annulus of fixed luminance. The reduction in discharge brought about by the annulus is independent of spot luminance. From this it is inferred that centre and surround signals combine additively. 3. Knowing that the combination of signals is additive, the surround signal can be estimated by comparing the ganglion cell's response to diffuse illumination of its receptive field with that to an equiluminous spot which optimally stimulates the centre while encroaching minimally upon the periphery. 4. Application of this technique to X‐cells shows that although the surround seems to have a threshold, it is at its most sensitive in the dark‐adapted eye, and typically is only 0.3–0.5 log units less sensitive than the centre. 5. Centre and surround sensitivities are decreased from their dark‐adapted levels by increasing background illumination, but the decline of surround sensitivity is initially less rapid than that of the centre. Thus with increasing light‐adaptation the surround becomes relatively more sensitive. In the light‐adapted eye centre and surround are about equally sensitive to diffuse illumination. 6. Although, in the dark‐adapted eye, illumination of the receptive field periphery of an on‐centre unit depresses firing, removal of that illumination produces no off‐discharge. Off‐discharges appear only when background illumination exceeds about 104 quanta (507)/deg 2 sec. This confirms Barlow & Levick (1969b). 7. In the dark‐adapted eye surround latency is longer than that of the centre. With increasing background illumination the latency difference is reduced. 8. For X‐cells, the rate of the maintained discharge depends to some extent on the balance of centre‐surround antagonism. But this antagonism is not the major factor accounting for the relative constancy of mean rate at high background luminances, for the rate then can be almost independent of the size of a steady pot. 9. The mean rate of discharge of Y‐cells seems to depend even less upon the balance of centre‐surround antagonism. 10. Y‐cell surrounds could not properly be isolated with the optimal spot‐diffuse illumination technique, so detailed measurements of their behaviour were not made. However, the dark‐adapted surround appear to be as sensitive as those of X‐cells.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1975.sp010947

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 179

Metadata

Authors
Enroth‐Cugell, C., & Lennie, P.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1975-06
Volume
247
Issue
3
Pages
551-578
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2039711456
Cited by
179
References
2
FWCI
5.68
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The control of retinal ganglion cell discharge by receptive field surrounds. https://app.cochat.ai/papers/10.1113/jphysiol.1975.sp010947
The paper
Enroth‐Cugell, C., & Lennie, P. (1975). The control of retinal ganglion cell discharge by receptive field surrounds. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1975.sp010947

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.