Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 332

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

The number of transmitter molecules in a quantum: an estimate from iontophoretic application of acetylcholine at the neuromuscular synapse.

Open access
Kuffler, S W, Yoshikami, D·1975·The Journal of Physiology

Abstract

1. The sensitivity of the subsynaptic membrane of twitch muscles of the frog and snake to iontophoretically applied acetylcholine (ACh) was determined. Optimal placement of ACh micropipettes on to the postsynaptic membrane resulted in potentials that were similar, though not identical, to the miniature excitatory post‐synaptic potentials (min e.p.s.p.s). A sensitive bio‐assay was developed to measure the output of ACh from micropipettes; this allowed an estimate to be made of the upper limit of the number of ACh molecules in a quantum of transmitter that is released from the nerve to produce a min e.p.s.p. 2. The assay to calibrate the output of ACh from micropipettes used the end‐plate of the snake muscle as an ACh concentration detector. The end‐plate was situated within a few mum of an oil‐water interface, and a 0‐6 nl. droplet of Ringer solution containing a known concentration of ACh (1 muM or less) was formed in the oil phase. The droplet was brought to the interface and, upon touching it, discharged its contents into the Ringer phase immediately above the end‐plate. This resulted in a membrane depolarization that was recorded with an intracellular microelectrode. By applying droplets containing various known ACh concentrations a standard curve was constructed. To measure the ACh output of micropipettes a 0‐6 nl. droplet of Ringer solution was suspended in the oil. The ACh pipette tip was inserted into the droplet and several thousand pulses of ACh were then delivered. The ACh content of the test droplet was measured by comparing its effectiveness in depolarizing the end‐plate with the standard curve. In this manner the number of ACh molecules released in a single pulse was determined as a function of charge passed through the pipette. The output of ACh was linear and an average of 30,000 molecules of ACh were released per pC. 3. The sensitivity of the subsynaptic membrane to iontophoretically applied ACh, using the linear slopes of dose‐response curves, in preparations from frog and snake treated with anticholinesterases was usually about 5 mV/pC. It follows that 6000 molecules of ACh are sufficient to produce a depolarization of 1 mV in the subsynaptic membrane. 4. The mean min e.p.s.p.s of muscle fibres treated with anticholinesterase range from 1 to 3 mV. Since the ACh released from an iontophoretic pipette is less effective than the same amount released from the nerve, it is concluded that a quantum of transmitter consists of less than 10,000 molecules of ACh. 5. It is calculated that for each molecule of ACh released in a quantum there results a minimum net flow of 3000 univalent ions across the synaptic membrane.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1975.sp011103

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 332

Metadata

Authors
Kuffler, S. W., & Yoshikami, D.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1975-10
Volume
251
Issue
2
Pages
465-482
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2050859687
Cited by
332
References
9
FWCI
3.48
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The number of transmitter molecules in a quantum: an estimate from iontophoretic application of acetylcholine at the neuromuscular synapse. https://app.cochat.ai/papers/10.1113/jphysiol.1975.sp011103
The paper
Kuffler, S. W., & Yoshikami, D. (1975). The number of transmitter molecules in a quantum: an estimate from iontophoretic application of acetylcholine at the neuromuscular synapse. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1975.sp011103

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.