Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 314

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Servo action in the human thumb.

Open access
Marsden, C D, Merton, P A, Morton, H B·1976·The Journal of Physiology

Abstract

1. The servo‐like properties of muscle in healthy human subjects have been studied by interfering unexpectedly with flexion movements of the top joint of the thumb. This movement is carried out by the flexor pollicis longus muscle only. 2. The movements were standardized in rate by giving the subject a tracking task. They started off against a constant torque load offered by an electric motor. 3. In some movements the load remained constant, but in others, in mid‐course, perturbations were introduced at random. Either the movement was halted, or released and allowed to accelerate by reducing the load, or reversed by suddenly increasing the current in the motor, so stretching the muscle. 4. Usually eight or sixteen responses to each kind of perturbation and a similar number of controls against a constant load were averaged. 5. Muscle activity was recorded as the electromyogram from surface electrodes over the belly of the long flexor in the lower forearm. Action potentials were usually full‐wave rectified and integrated. 6. About 50 msec after a perturbation the muscle's activity alters in such a sense as to tend to compensate for the perturbation, i.e. it increases after a halt or a stretch and decreases after a release. The latency is similar in each case. 7. These responses are interpreted as manifestations of automatic servo action based on the stretch reflex. They are considered to be too early to be voluntary. 8. This interpretation was supported by measuring voluntary reaction times to perturbations under tracking conditions. They were found to be 90 msec or longer. 9. When the initial load was increased by a factor of 10, the servo responses were all scaled up likewise. Thus to a first approximation the gain of the servo is proportional to initial load. 10. It follows that in relaxed muscle the gain should be zero. This was confirmed by showing that stretching a relaxed muscle gives no reflex, or only a small one. 11. Gain appears to be determined by the level of muscle activation as determined by the effort made by the subject, rather than by the actual pressure exerted by the thumb. 12. Thus in fatigued muscle gain is boosted as the muscle has to be activated more strongly to keep up the same force output. The net effect is to compensate for fatigue and maintain the performance of the servo. 13. The Discussion centres on the implications of gain control in the servo. For a start, if the gain of the stretch reflex arc is zero in relaxed muscle, contractions cannot be initiated via the stretch reflex by simply causing the spindles to contract, as proposed on the original ‘follow‐up’ servo theory.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1976.sp011354

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 314

Metadata

Authors
Marsden, C. D., Merton, P. A., & Morton, H. B.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1976-05
Volume
257
Issue
1
Pages
1-44
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2047436926
Cited by
314
References
1
FWCI
9.20
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Servo action in the human thumb. https://app.cochat.ai/papers/10.1113/jphysiol.1976.sp011354
The paper
Marsden, C. D., Merton, P. A., & Morton, H. B. (1976). Servo action in the human thumb. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1976.sp011354

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.