CoChat

Analysis of electrical noise in turtle cones

Open access
Lamb, T. D., Simon, E. J. · 1977 · The Journal of Physiology
Cited by 87

The DOI matches its Crossref record.

Abstract

1. Properties of the light‐sensitive voltage noise in cones in the retina of the turtle, Pseudemys scripta elegans, have been studied by intracellular recording. 2. Suppression of the noise by light was a function of the hyperpolarizing response of a cone but not of the size or pattern of illumination. 3. Power density spectra of the noise were fitted in many cones by the product of two Lorentzians with characteristic time constants τ 1 and τ 2 averaging 40 and 7 msec respectively. The spectra of some cells were peaked and could be fitted by a resonance curve. 4. Spectra in dim light exhibited decreased low frequency power. They could often be fitted by a product of two Lorentzians using the same value of τ 2 as used in darkness but decreasing τ 1 and the zero frequency asymptote. An e‐fold reduction in τ 1 occurred with lights which hyperpolarized by 4‐7 mV. 5. Injection of hyperpolarizing currents of about 0·1‐0·2 nA into weakly coupled cones reduced the noise, and also reduced the sensitivity to dim flashes. 6. The variance‐voltage relation during steady illumination of different intensities differed from cone to cone. Dim lights increased the noise in some cells and decreased it in others, but moderately bright lights which gave steady responses of more than about one third maximal reduced the noise in all cells. 7. When the cell was transiently depolarized during the differentiated component following steady illumination, the noise was less than it was after prolonged darkness. 8. In the after‐effect of bright light, the time course of recovery of noise was the same as that of flash sensitivity and voltage. The noise was reduced e‐fold for hyperpolarizations averaging 3 mV while for sensitivity this reduction occurred for 1·3 mV. For a given hyperpolarization the noise was lower during the after‐effect than during steady dim illumination. 9. When a series of dim flashes was delivered to a cone, no significant increase in variance over the dark noise was detected during the photo‐response. This implies that each photoisomerization evokes no more than about 1·5 μV at the peak of the response in a coupled cone, corresponding to about 50 μV in an isolated cone. 10. The elementary shot events underlying the noise are about 100 μV in amplitude in an isolated cone, have a characteristic time constant of 16‐60 msec and reflect unit conductance fluctuations of about 16 pS (S, Siemen ≡ Ω−1). 11. It is concluded that the noise source is internal to the cones. We postulate that the noise arises from opening and closing of the light‐sensitive ionic channels in the outer segment, and that in darkness there is a residual concentration of the blocking substance which on average closes up to about one third of the channels. It seems likely that the unit event involves a considerable number of blocking molecules and ionic channels.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1977.sp012053

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Lamb, T. D., & Simon, E. J.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1977-11
Volume
272
Issue
2
Pages
435-468
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2048680198
Cited by
87
References
0
FWCI
3.17
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.