Selective Activation of peripheral nerve fibre groups of different diameter by triangular shaped stimulus pulses.
Open accessThe DOI matches its Crossref record.
Abstract
1. The differential block of cutaneous nerve fibres has been achieved with a simple method of electrical stimulation, employing a single pair of active electrodes. 2. The method allows the selective activation of 95% of small myelinated (delta) axons, without activation of the larger (beta) ones; and activation of unmyelinated (C) fibres, without A fibre activation. Asynchronous firing of myelinated axons was absent in the majority of the experiments. 3. The method employs triangularly shaped electrical pulses, with a steep rise front and a slow exponential decay. The outward flow of current at the cathode fires conducted impulses in both larger and smaller axons, and the inward flow inactivates differentially the conduction in the smaller ones. 4. The differential effect of anodal currents rests upon the greater internal conductance and greater conduction velocity of larger fibres. 5. The method has the advantage over the conventional polarization block of simpler surgical preparation, longer nerve survival and minimal latency distortion. However, it cannot be applied in experiments requiring physiological stimulation of peripheral receptors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Rácz, I., & Zimmer, A. (2006) · Standards of Mouse Model Phenotyping · doi:10.1002/9783527611942.ch9 · Cited by 1,659
Le Bars, D., Gozariu, M., & Cadden, S. W. (2001) · Pharmacological Reviews · doi:10.1016/s0031-6997(24)01514-x · Cited by 1,459
Nerve conduction block utilising high-frequency alternating current
Kilgore, K. L., & Bhadra, N. (2004) · Medical & Biological Engineering & Computing · doi:10.1007/bf02344716 · Cited by 284
Selective activation of small motor axons by quasitrapezoidal current pulses
Fang, Z.-P., & Mortimer, J. T. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.76383 · Cited by 222
Implantable bioelectronic interfaces for lost nerve functions
Heiduschka, P., & Thanos, S. (1998) · Progress in Neurobiology · doi:10.1016/s0301-0082(98)00013-6 · Cited by 126
Metadata
- Authors
- Accornero, N., Bini, G., Lenzi, G. L., & Manfredi, M.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1977-12
- Volume
- 273
- Issue
- 3
- Pages
- 539-560
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2052564270
- Cited by
- 122
- References
- 0
- FWCI
- 0.63
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Selective Activation of peripheral nerve fibre groups of different diameter by triangular shaped stimulus pulses. https://app.cochat.ai/papers/10.1113/jphysiol.1977.sp012109
- The paper
- Accornero, N., Bini, G., Lenzi, G. L., & Manfredi, M. (1977). Selective Activation of peripheral nerve fibre groups of different diameter by triangular shaped stimulus pulses. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1977.sp012109
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.