Axonal conduction velocity and voluntary discharge properties of individual short toe extensor motor units in man.
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
1. The axonal conduction velocity and the voluntary discharge properties of 120 short toe extensor motor units were studied in man. 2. Electromyographic techniques were used which permitted the identification of individual motor unit potentials after proximal and distal electrical nerve stimulation and during maximum voluntary effort. 3. The necessary selectivity of the e.m.g. recordings was achieved in two circumstances. In some subjects, previous motor nerve lesions distal to the point of stimulation had led to collateral sprouting with larger motor unit potentials. In other subjects an accessory deep peroneal nerve was present, so that lidocaine block of the main motor nerve left a small number of innervated motor units. 4. The axonal conduction velocities of the individual motor units ranged from 30 to 54 m/sec with most motor units between 35 and 45 m/sec. 5. Motor units which voluntarily could be driven continuously at frequencies below 10/sec had axonal conduction velocities between 30 and 45 m/sec. 6. Motor units which on voluntary drive responded only in high frequency bursts had axonal conduction velocities between 40 and 54 m/sec. 7. Motor units with intermediate voluntary discharge properties had intermediate axonal conduction velocities. 8. Thus a relationship was established between voluntary discharge properties and axonal conduction velocity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PROPERTIES OF MOTOR UNITS IN A HOMOGENEOUS RED MUSCLE (SOLEUS) OF THE CAT
McPhedran, A. M., Wuerker, R. B., & Henneman, E. (1965) · Journal of Neurophysiology · doi:10.1152/jn.1965.28.1.71 · Cited by 323
PROPERTIES OF MOTOR UNITS IN A HETEROGENEOUS PALE MUSCLE (M. GASTROCNEMIUS) OF THE CAT
Wuerker, R. B., McPhedran, A. M., & Henneman, E. (1965) · Journal of Neurophysiology · doi:10.1152/jn.1965.28.1.85 · Cited by 318
Grimby, L., & Hannerz, J. (1977) · The Journal of Physiology · doi:10.1113/jphysiol.1977.sp011699 · Cited by 303
Self-citation
Cited by
Motor Units: Anatomy, Physiology, and Functional Organization
Burke, R. E. (1981) · Comprehensive Physiology · doi:10.1002/cphy.cp010210 · Cited by 782
Physiology and Mathematics of Myoelectric Signals
De Luca, C. J. (1979) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1979.326534 · Cited by 684
Functional Organization of Motoneuron Pool and its Inputs
Henneman, E., & Mendell, L. M. (1981) · Comprehensive Physiology · doi:10.1002/cphy.cp010211 · Cited by 436
Motor unit firing rates and contractile properties in tibialis anterior of young and old men
Connelly, D. M., Rice, C. L., Roos, M. R., & Vandervoort, A. A. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.2.843 · Cited by 340
“Previous studies of human extensor digitorum brevis muscle found that during voluntary contractions MUs firing at low frequencies (,10 Hz) had slow axonal conduction velocities (30 and 35 m/s) and MUs firing mainly in high-frequency bursts had fast axonal conduction velocities (40 and 54 m/s) (8).”
BackgroundAAEM minimonograph #13: H reflexes and F waves: Physiology and clinical indications
Fisher, M. A. (1992) · Muscle & Nerve · doi:10.1002/mus.880151102 · Cited by 295
Grimby, L., Hannerz, J., & Hedman, B. (1979) · The Journal of Physiology · doi:10.1113/jphysiol.1979.sp012732 · Cited by 80
Self-citation
Metadata
- Authors
- Borg, J., Grimby, L., & Hannerz, J.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1978-04
- Volume
- 277
- Issue
- 1
- Pages
- 143-152
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W1987654118
- Cited by
- 67
- References
- 3
- FWCI
- 7.54
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.