Tactile sensibility in the human hand: receptive field characteristics of mechanoreceptive units in the glabrous skin area
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
1. Impulses in tactile units innervating the glabrous skin of the hand recorded from the median nerve of adult human subjects. The recording electrodes which were made of tungsten were inserted percutaneously in the upper arm. 2. The units were classified on the basis of their sensitivity to sustained identation and to remote stimuli. Two types of rapidly adapting units and two types of slowly adapting units were found. In accordance with earlier reports they were denoted RA and PC units, and SA I and SA II units. 3. The sensitivity profiles of the receptive fields were analysed by measuring the extent of the receptive field as a function of the identation amplitude. 4. The RA and SA I units had receptive fields with several zones of maximal sensitivity distributed over an approximately circular or oval area typically covering five to ten papillary ridges. Within this area the sensitivity was high, whereas the sensitivity diminished steeply with increasing distance from this area. 5. The PC and SA II units had receptive fields with a single zone of maximal sensitivity and gentle continuous threshold increase outside this zone. 6. The relation between the identation amplitude and the receptive field size of a unit was described by a power function. The power exponent for the RA and SA I units was well below unity, whereas the PC and SA II units had exponenets greater than unity. The variation in exponent was very small among the RA and among the SA I units. Their average exponents were therefore regarded as characteristics of the unit type. 7. The SA II units were qualitatively studied with regard to their sensitivity to lateral skin stretch. Three different types of SA II units were described with regard to the directional pattern of this sensitivity. 8. The relation of the present findings to the problem of correlation between morphological structures of nerve end‐organs and physiologically defined unit types is considered. 9. Moreover, the findings, indicate that the RA and SA I units are well suited for the analysis of mechanical events on the skin surface with a high degree of spatial selectivity, whereas the PC and SA II units are suited for analysis of other mechanical events, e.g. vibration and various forms of tension in the skin and related tissues.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The text we found for this paper looks like another document, so the self-check wasn’t run.
Citations
Cites
Talbot, W. H., Darian-Smith, I., Kornhuber, H. H., & Mountcastle, V. B. (1968) · Journal of Neurophysiology · doi:10.1152/jn.1968.31.2.301 · Cited by 990
The structure and function of a slowly adapting touch corpuscle in hairy skin
Iggo, A., & Muir, A. R. (1969) · The Journal of Physiology · doi:10.1113/jphysiol.1969.sp008721 · Cited by 817
Activity from skin mechanoreceptors recorded percutaneously in awake human subjects
Vallbo, Å. B., & Hagbarth, K.-E. (1968) · Experimental Neurology · doi:10.1016/0014-4886(68)90041-1 · Cited by 530
THE STRUCTURE AND FUNCTION OF THE SLOWLY ADAPTING TYPE II MECHANORECEPTOR IN HAIRY SKIN
Chambers, M. R., Andres, K. H., Duering, M. V., & Iggo, A. (1972) · Quarterly Journal of Experimental Physiology and Cognate Medical Sciences · doi:10.1113/expphysiol.1972.sp002177 · Cited by 463
Mountcastle, V. B., LaMotte, R. H., & Carli, G. (1972) · Journal of Neurophysiology · doi:10.1152/jn.1972.35.1.122 · Cited by 404
Stimulus‐response functions of slowly adapting mechanoreceptors in the human glabrous skin area.
Knibestöl, M. (1975) · The Journal of Physiology · doi:10.1113/jphysiol.1975.sp010835 · Cited by 335
Single Unit Analysis of Mechanoreceptor Activity from the Human Glabrous Skin
Knibestöl, M., & Vallbo, Å. B. (1970) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1970.tb04783.x · Cited by 281
Stimulus—response functions of rapidly adapting mechanoreceptors in the human glabrous skin area
Knibestöl, M. (1973) · The Journal of Physiology · doi:10.1113/jphysiol.1973.sp010279 · Cited by 258
Johnson, K. O. (1974) · Journal of Neurophysiology · doi:10.1152/jn.1974.37.1.48 · Cited by 230
Merzenich, M., & Harrington, T. (1969) · Experimental Brain Research · doi:10.1007/bf00234457 · Cited by 184
Cited by
Items 401–428 of 428
(1994) · Advances in psychology · doi:10.1016/s0166-4115(08)61586-1
Kim, S. S. (2015) · Springer eBooks · doi:10.1007/978-1-4614-6675-8_380
Role of Single Mechanoreceptor Units in Tactile Sensation
Torebjörk, H. E., Ochoa, J. L., & Schady, W. (1984) · Springer eBooks · doi:10.1007/978-1-4613-2807-0_11
Physiological Characteristics of Second-Order Somatosensory Circuits in Spinal Cord and Brainstem
Willis, W. D. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-805408-6.00348-1
Kim, S. S. (2013) · Springer eBooks · doi:10.1007/978-1-4614-7320-6_380-2
“Three types of mechanoreceptors innervate primate glabrous skin: slowly adapting type 1 (SA), rapidly adapting (RA), and Pacinian (PC) afferents (Gescheider et al. 2004; Hsiao and Bensmaia 2008; Johansson 1978; Johnson 2001; Pare et al. 2002; Talbot et al. 1968).”
BackgroundKim, S. S. (2022) · Springer eBooks · doi:10.1007/978-1-0716-1006-0_380
Mechanorezeptoren von Haut und Muskeln: Die Sensorik mechanischer Schwingungen
Ribot‐Ciscar, E. (2023) · Springer eBooks · doi:10.1007/978-3-031-13621-4_6
Gaede, A. H., Wu, P., & Leitch, D. B. (2023) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2023.10.30.564821
“For example, human fingertips and the lips have minute receptive fields and a high density of touch receptors, providing peripheral adaptations for high sensitivity and precision in tactile discrimination 37 .”
BackgroundHachisuka, J. (2024) · The Nishinihon Journal of Dermatology · doi:10.2336/nishinihonhifu.86.215
Vibrotactile Information Coding Strategies for a Body-Worn Vest to Aid Robot-Human Collaboration
Tercero, A. V., & Caleb-Solly, P. (2025) · Lecture notes in computer science · doi:10.1007/978-981-96-3525-2_39
Memory at your fingertips: how viscoelasticity affects tactile neuron signalingPreprint
Saal, H. P., Birznieks, I., & Johansson, R. S. (2025) · eLife · doi:10.7554/elife.89616.2
Self-citationCady, S. R., Lambrecht, J. M., & Tyler, D. J. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/ae24ae · Cited by 1
“The 64-channel system produced more overlapping percept locations than the 16-channel system, which was expected due to the closer-spaced C-FINE contacts and greater likelihood of recruiting adjacent or identical axonal populations with overlapping receptive fields [10, 11, 37].”
The Use of Topical Anesthesia in the Rehabilitation of Patients with Spasticity
Sabbahi, M. (1987) · Elsevier eBooks · doi:10.1016/b978-0-409-90022-4.50013-0
Vibration Alert Interface における振動周波数に対する振動感覚順応とそのモデル化
森, 友., 田中, 孝., 金子, 俊., & 片桐, 祥. (2012) · ヒューマンインタフェース学会論文誌 · doi:10.11184/his.14.3_293
Amélioration de l'acuité proprioceptive par la stimulation des récepteurs cutanés
Thedon, T. (2010) · theses.fr (ABES) · doi:10.70675/9bc294f2zeba7z40afz9781z4de9560c5332 · Cited by 1
Retour sensoriel du toucher dans les environnements virtuels
Lassagne, A. (2018) · theses.fr (ABES) · doi:10.70675/0e7bcd53ze68dz4bb1z8f7czf7e140080fed
Viseux, F. (2020) · theses.fr (ABES) · doi:10.70675/03665ad9z8514z4df0z9593z145490cf2725 · Cited by 1
Devices for Communication with Individuals who are Deafblind
Duvernoy, B. (2020) · theses.fr (ABES) · doi:10.70675/fe288618z5375z4c10za0dbza55a8d63e633 · Cited by 2
Cabaret, P.-A. (2024) · theses.fr (ABES) · doi:10.70675/cd07c32ez2d0ez472bz9632z185798160612
La sensibilité tactile au travers des liquides et du vieillissement : approches multidisciplinaires
Samain-Aupic, L. (2023) · theses.fr (ABES) · doi:10.70675/008b8615z7c3dz479azb516z1e4445ad23bd
Neotropical Freshwater Fishes of Seasonally Hypoxic Waters
Heinrichs-Caldas, W., Campos, D. F., da Costa, J. C., Kochhann, D., Mota, S. B., Val, A. L., & de Almeida‐Val, V. M. F. (2026) · Fascinating life sciences · doi:10.1007/978-3-032-09328-8_12
Viseux, F., Sutter, C., & Viseu, J.-P. (2026) · EMC - Podología · doi:10.1016/s1762-827x(26)51927-8
Larsson, J. E., Nagi, S. S., Jarocka, E., Ng, K. K. W., Fältskytt, M., Marshall, A. G., McIntyre, S., Gerling, G. J., & Olausson, H. (2026) · The Journal of Physiology · doi:10.1113/jp290237 · Cited by 1
Human and artificial tactile sensing
Cabibihan, J. (2026) · Elsevier eBooks · doi:10.1016/b978-0-32-395519-5.00018-0
Lee, K. G. H. (2013) · MacSphere (McMaster University) · doi:10.71548/24834
(1984) · PubMed · Cited by 908
Self-citation
Metadata
- Authors
- Johansson, R. S.
- Corresponding author
- Johansson, R S
- ORCID
- Johansson, R S
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1978-08
- Volume
- 281
- Issue
- 1
- Pages
- 101-125
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- PMC
- PMC1282686
- OpenAlex
- W2012619381
- Semantic Scholar
- 1dec694386d4cc8654644590276784fb01206bc1
- Cited by
- 430
- References
- 35
- Citations by year
- 2026: 9 · 2025: 13 · 2024: 10 · 2023: 10 · 2022: 10 · 2021: 13 · 2020: 16 · 2019: 7 · 2018: 14 · 2017: 11 · 2016: 11 · 2015: 16 · 2014: 13 · 2013: 9 · 2012: 20
- FWCI
- 4.75
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- The Journal of Physiology (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Life Sciences › Neuroscience › Sensory Systems › Ion Channels and Receptors
- Keywords
- tactile sensitivity, mechanoreceptors, receptive fields, glabrous skin, hand, power function, median nerve, spatial selectivity
- MeSH terms
- Action Potentials, Adult, Female, Hand, Humans, Male, Mechanoreceptors, Skin, Touch
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.