Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 300

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Detection of tactile stimuli. Thresholds of afferent units related to psychophysical thresholds in the human hand.

Open access
Johansson, R S, Vallbo, A B·1979·The Journal of Physiology

Abstract

1. Psychophysical thresholds were determined at 162 points in the glabrous skin area of the human hand when slowly rising, triangular indentations of controlled amplitudes were delivered with a small probe. The method of constant stimuli was used with either the two alternative forced choice or the yes‐no procedure. It was found that the distribution of the psychophysical thresholds varied with the skin region. Thresholds from the volar aspect of the fingers and the peripheral parts of the palm were low and their distribution was unimodal with a median of 11.2 micrometers. In contrast, there was an over‐representation of high thresholds when observations from the centre of the palm, the lateral aspects of the fingers and the regions of the creases were pooled, and the distribution was slightly bimodal with a median of 36.0 micrometers. 2. Nerve impulses were recorded from single fibres in the median nerve of human subjects with percutaneously inserted tungsten needle electrodes. The thresholds of 128 mechanosensitive afferent units in the glabrous skin area of the hand were determined when stimuli were delivered to partly the same points as stimulated for the assessment of the psychophysical thresholds. Of the four types of units present in this area the Pacinian corpuscle (PC) and rapidly adapting (RA) units had the lowest thresholds with medians of 9.2 and 13.8 micrometers, followed by the slowly adapting type I and slowly adapting type II units with medians of 56.5 and 33.1 micrometers. There was no indication of a difference between thresholds of units located in different skin areas. 3. In the region of low psychophysical thresholds there was good agreement between the thresholds of the rapidly adapting and Pacinian corpuscle units and the psychophysical thresholds, particularly at the lower ends of the samples. In the skin regions of high thresholds, on the other hand, practically all psychophysical thresholds were higher than the thresholds of the most sensitive afferent units. Moreover, simultaneous recording of nerve impulses during a detection task indicated that subjects did not detect stimuli strong enough to elicit several impulses in afferent units in this region. 4. Circumstantial evidence led to the conclusion that detection was dependent on one impulse in one or a few rapidly adapting units under optimal conditons in the region of low psychophysical thresholds, whereas it seemed unlikely that activity in Pacinian corpuscle units was crucial. 5. The findings are consistent with the interpretation that human subjects are able to detect an input consisting of a single impulse in a single rapidly adapting unit.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1979.sp013048

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 300

Metadata

Authors
Johansson, R. S., & Vallbo, A. B.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1979-12
Volume
297
Issue
1
Pages
405-422
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W1975509674
Cited by
300
References
2
FWCI
2.24
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Detection of tactile stimuli. Thresholds of afferent units related to psychophysical thresholds in the human hand. https://app.cochat.ai/papers/10.1113/jphysiol.1979.sp013048
The paper
Johansson, R. S., & Vallbo, A. B. (1979). Detection of tactile stimuli. Thresholds of afferent units related to psychophysical thresholds in the human hand. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1979.sp013048

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.