CoChat

Strength‐duration characteristics of myelinated and non‐myelinated bulbospinal axons in the cat spinal cord.

Open access
West, D C, Wolstencroft, J H · 1983 · The Journal of Physiology
Cited by 92

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Strength‐duration characteristics for the stimulation of 131 raphespinal and reticulospinal axons in the spinal cord were determined using two types of stimulating electrode. Conduction velocity of these fibres ranged from 0.86 to 63 m/s. With silver wire (250 micron diameter) stimulating electrodes, chronaxies were: 0.18 +/‐ 0.06 ms for axons conducting between 16 and 63 m/s, 0.4 +/‐ 0.22 ms for axons conducting between 5 and 15 m/s and 2.06 +/‐ 0.79 ms for those with conduction velocity less than 5 m/s. There was an inverse relationship between chronaxie and conduction velocity. Rheobase values ranged from 7.4 to 400 microA but were independent of conduction velocity. Chronaxies obtained with wire electrodes were compared with those from stimulation of the same fibre through saline‐filled micropipettes (2‐12 micron tip diameter). Rheobase values with the micropipettes ranged from 1.6 to 20 microA, indicating a close proximity of the pipette to the axon. For these axons, chronaxies from metal wire electrodes ranged from 0.12 to 2.4 ms and for micropipettes from 0.04 to 0.65 ms. In almost all cases, chronaxies for micropipette stimulation were lower than those for metal wire electrodes. Furthermore, with micropipettes chronaxies were independent of conduction velocity. The results are shown to be related to differences in time constant of the activated region of axon and charge requirements of threshold activation. The two stimulating conditions, i.e. micro‐electrodes compared with wire electrodes, are analogous to the theoretical point stimulated cable and uniformly polarized membrane cases. The results are discussed in relation to the possibility of determination of fibre type from stimulation characteristics. A distinction between chronaxies of myelinated and non‐myelinated fibres can be made using wire electrodes of 250 micron diameter, but not with micro‐stimulation, as with micropipettes (2‐12 micron diameter).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1983.sp014610

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 92

Metadata

Authors
West, D. C., & Wolstencroft, J. H.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1983-04
Volume
337
Issue
1
Pages
37-50
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2014136357
Cited by
92
References
1
FWCI
1.10
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Strength‐duration characteristics of myelinated and non‐myelinated bulbospinal axons in the cat spinal cord. https://app.cochat.ai/papers/10.1113/jphysiol.1983.sp014610
The paper
West, D. C., & Wolstencroft, J. H. (1983). Strength‐duration characteristics of myelinated and non‐myelinated bulbospinal axons in the cat spinal cord. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1983.sp014610

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.