Direct observations of muscle arterioles and venules following contraction of skeletal muscle fibres in the rat.
Open accessThe DOI matches its Crossref record.
Abstract
Direct observations have been made of responses of individual arterioles and venules of rat spinotrapezius muscle to contraction of the skeletal muscle fibres. Stimuli of 4‐6 V intensity, 0.1 ms duration, delivered via a micro‐electrode inserted into the spinotrapezius, evoked contraction of a small bundle of skeletal muscle fibres, followed by vasodilatation which was limited to all those arterioles and venules which crossed or ran alongside activated muscle fibres. Since venules outside the region of contraction, but supplied by dilating arterioles, were not passively distended by the attendant rise in intravascular pressure, it is concluded that both the arterioles and venules dilated actively in response to muscle contraction. All arterioles responded to a single twitch contraction, the terminal arterioles (7‐13 micron i.d.) showing the largest increase in diameter. Collecting venules (9‐18 micron i.d.) responded to just two twitches in 1 s and larger venules to five twitches in 1 s. When twitch contractions were continuously evoked for 10 s, the responses in individual arterioles and venules were graded with twitch frequency, the fastest and largest response occurring at 6‐8 Hz. Tetanic contraction, at 40 Hz for 1 s, produced faster responses in all vessels, a maximum 55% increase from resting internal diameter being attained in only 8 s in some terminal arterioles. In all vessels the responses to tetanic contraction were equal to the maximal dilatation induced by papaverine. These results, in contrast with conclusions drawn from indirect estimates of venous responses, show that venules, like arterioles, dilate actively in response to muscle contraction. Venule dilatation may reduce the rise in capillary hydrostatic pressure, thereby limiting the outward filtration of fluid.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Joyner, M. J., & Casey, D. P. (2015) · Physiological Reviews · doi:10.1152/physrev.00035.2013 · Cited by 833
Rossi, P., Andriesse, G. I., Oey, P. L., Wieneke, G. H., Roelofs, J. M. M., & Akkermans, L. M. A. (1998) · Journal of the Neurological Sciences · doi:10.1016/s0022-510x(98)00276-7 · Cited by 767
Regulation of Blood Flow in the Microcirculation
SEGAL, S. S. (2005) · Microcirculation · doi:10.1080/10739680590895028 · Cited by 540
Poole, D. C., & Jones, A. M. (2012) · Comprehensive Physiology · doi:10.1002/cphy.c100072 · Cited by 514
Vasodilatory mechanisms in contracting skeletal muscle
Clifford, P. S., & Hellsten, Y. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00179.2004 · Cited by 447
Metadata
- Authors
- Marshall, J. M., & Tandon, H. C.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1984-05
- Volume
- 350
- Issue
- 1
- Pages
- 447-459
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2144107055
- Cited by
- 116
- References
- 0
- FWCI
- 4.83
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Direct observations of muscle arterioles and venules following contraction of skeletal muscle fibres in the rat. https://app.cochat.ai/papers/10.1113/jphysiol.1984.sp015211
- The paper
- Marshall, J. M., & Tandon, H. C. (1984). Direct observations of muscle arterioles and venules following contraction of skeletal muscle fibres in the rat. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1984.sp015211
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.