Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 555

The DOI matches its Crossref record.

Exercise‐induced arterial hypoxaemia in healthy human subjects at sea level.

Open access
Dempsey, J A, Hanson, P G, Henderson, K S·1984·The Journal of Physiology

Abstract

We determined the incidence of exercise‐induced arterial hypoxaemia and its determinants in sixteen highly trained, healthy runners who were capable of achieving and sustaining very high metabolic rates (maximal O2 uptake = 72 +/‐ 2 ml kg‐1 min‐1 or 4.81 +/‐ 0.13 l min‐1). Arterial blood gases and acid‐base status were determined at each load of a progressive short‐term exercise test and repeatedly during constant‐load treadmill running while breathing air and during inhalation of mildly hypoxic, hyperoxic, and helium‐enriched gases. Three types of responses to heavy and maximum exercise were evident and highly reproducible within subjects. Four runners maintained arterial PO2 (Pa, O2) within 10 mmHg of resting values, another four showed 10‐15 mmHg reductions in Pa, O2, and the remaining eight showed reductions of 21‐35 mmHg, i.e. in all cases to a Pa, O2 of less than 75 mmHg and to less than 60 mmHg in two cases. During constant‐load exercise, Pa, O2 was often maintained during the initial 30 s when hyperventilation was greatest; then hypoxaemia occurred and in most cases was either maintained or worsened over the ensuing 3‐4 min. The most severe hypoxaemia during heavy exercise was associated with no or little alveolar hyperventilation (Pa, CO2 greater than 35 mmHg and PA, O2 less than 110 mmHg) and an alveolar to arterial PO2 difference [(A‐a)DO2] in excess of 40 mmHg. During 3‐4 min of heavy exercise alveolar PO2 (PA, O2) decreased by 20 mmHg in mild hypoxia (0.17 FI, O2; inspired % O2) and increased by 20 mmHg during mild hyperoxia (0.24 FI, O2) and 10 mmHg during the hyperventilation which accompanied normoxic helium breathing. In all cases Pa, O2 changed in proportion to PA, O2 with no consistent change in the alveolar to arterial PO2 difference [(A‐a)DO2]. In view of the correction of hypoxaemia with mild hyperoxia and the very high ratios of alveolar ventilation to pulmonary blood flow (VA/QC = 4‐6) achieved during heavy exercise, we think it unlikely that non‐uniformity of the VA/QC distribution or veno‐arterial shunt could explain the hypoxaemia observed in most of our subjects. By exclusion, we suggest that hypoxaemia may be attributed to a diffusion limitation secondary to very short red cell transit times in at least a portion of the pulmonary circulation.(ABSTRACT TRUNCATED AT 400 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1984.sp015412

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 555

Metadata

Authors
Dempsey, J. A., Hanson, P. G., & Henderson, K. S.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1984-10
Volume
355
Issue
1
Pages
161-175
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2041689988
Cited by
555
References
0
FWCI
2.17
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Exercise‐induced arterial hypoxaemia in healthy human subjects at sea level. https://app.cochat.ai/papers/10.1113/jphysiol.1984.sp015412
The paper
Dempsey, J. A., Hanson, P. G., & Henderson, K. S. (1984). Exercise‐induced arterial hypoxaemia in healthy human subjects at sea level. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1984.sp015412

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.