Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 177

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Membrane patches and whole‐cell membranes: a comparison of electrical properties in rat clonal pituitary (GH3) cells.

Open access
Fernandez, J M, Fox, A P, Krasne, S·1984·The Journal of Physiology

Abstract

A comparison has been made between the electrical properties of excised 'outside‐out' patches and whole‐cell membranes of GH3 cells using the patch‐pipette technique. Despite a complicated surface morphology, which includes numerous microvilli, ruffles and blebs, high‐resistance seals (typically greater than 10(11) omega) were consistently formed between patch pipettes and GH3 cell membranes. When the internal solution contained 120 mM‐CsF, outward currents through K channels were blocked and large Na channel currents were consistently observed in the whole‐cell recording mode. Using the same solutions, single Na channel currents were readily observed in outside‐out patches. Averaging patch currents yielded macroscopic currents showing the same voltage‐dependent kinetics as those observed for the whole‐cell membrane. The current vs. voltage and inactivation time constant vs. voltage relationships for the Na channel shifted towards more negative potentials (25 mV or more) within approximately 30 min after going into the whole‐cell recording mode. These same relationships could be measured for outside‐out patches and their positions along the voltage axis coincided with the asymptotic values measured in the whole‐cell mode. When the internal solution contained 120 mM‐N‐methylglucamine fluoride and the external solution contained 120 mM‐Tris chloride, no ionic channel currents could be observed either for whole‐cell or outside‐out patch membranes. Under these conditions, displacement currents induced by tetraphenyl borate (TPB) were recorded in both types of membranes. The total charge moved showed a sigmoidal dependence upon the applied voltage for both whole‐cell and outside‐out patch membranes. The charge vs. voltage relationship showed a shift along the voltage axis similar to that observed for Na channels except that the magnitude of the shift was larger. A shift in this relationship was also observed for excised patches but the observable magnitude of the shift was smaller than that in the whole‐cell recording mode. The asymptotic values of the charge vs. voltage relationship were similar for whole‐cell and outside‐out patches, as were the asymptotic values for the translocation time constants. It is concluded that there are no fundamental differences in the properties of ionic channel and displacement currents between whole‐cell membranes and excised membrane patches.(ABSTRACT TRUNCATED AT 400 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1984.sp015483

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 177

Metadata

Authors
Fernandez, J. M., Fox, A. P., & Krasne, S.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1984-11
Volume
356
Issue
1
Pages
565-585
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W1978247434
Cited by
177
References
2
FWCI
5.02
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Membrane patches and whole‐cell membranes: a comparison of electrical properties in rat clonal pituitary (GH3) cells. https://app.cochat.ai/papers/10.1113/jphysiol.1984.sp015483
The paper
Fernandez, J. M., Fox, A. P., & Krasne, S. (1984). Membrane patches and whole‐cell membranes: a comparison of electrical properties in rat clonal pituitary (GH3) cells. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1984.sp015483

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.