Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 404

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

A voltage‐gated potassium channel in human T lymphocytes.

Open access
Cahalan, M D, Chandy, K G, DeCoursey, T E, Gupta, S·1985·The Journal of Physiology

Abstract

Human peripheral T lymphocytes were studied at 20‐24 degrees C using the gigaohm seal recording technique in whole‐cell or outside‐out patch conformations. The predominant ion channel present under the conditions employed was a voltage‐gated K+ channel closely resembling delayed rectifier K+ channels of nerve and muscle. The maximum K+ conductance in ninety T lymphocytes ranged from 0.7 to 8.9 nS, with a mean of 4.2 nS. The estimated number of K+ channels per cell is 400, corresponding to a density of about three channels/micron2 apparent membrane area. The activation of K+ currents could be fitted by Hodgkin‐Huxley type n4 kinetics. The K+ conductance in Ringer solution was half‐maximal at ‐40 mV. The time constant of K+ current inactivation was practically independent of voltage except near the threshold for activating the K+ conductance. Recovery from inactivation was slow and followed complex kinetics. Steady‐state inactivation was half‐maximal at ‐70 mV, and was complete at positive potentials. Permeability ratios, relative to K+, determined from reversal potential measurements were: K+(1.0) greater than Rb+(0.77) greater than NH4+(0.10) greater than Cs+ (0.02) greater than Na+(less than 0.01). Currents through K+ channels display deviations from the independence principle. The limiting outward current increases when external K+ is increased, and Rb+ carries less inward current than expected from its relative permeability. Tail current kinetics were slowed about 2‐fold by raising the external K+ concentration from 4.5 to 160 mM, and were 5 times slower in Rb+ Ringer solution than in K+ Ringer solution. Single K+ channel currents had two amplitudes corresponding to about 9 and 16 pS in Ringer solution. Replacing Ringer solution with isotonic K+ Ringer solution increased the unitary conductance and resulted in inward rectification of the unitary current‐voltage relation. Comparable effects of external K+ were seen in the whole‐cell conductance and instantaneous current‐voltage relation. Several changes in the K+ conductance occurred during the first few minutes after achievement of the whole‐cell conformation. Most are explainable by dissipation of a 10‐20 mV junction potential between pipette solution and the cytoplasm, and by the use of a holding potential more negative than the resting potential. However, inactivation of K+ currents became faster and more complete, changes not accounted for by these mechanisms. K+ efflux through open K+ channels in intact lymphocytes, calculated from measured properties of K+ channels, can account for efflux values reported in resting lymphocytes, and for the increase in K+ efflux upon mitogenic stimulation.(ABSTRACT TRUNCATED AT 400 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1985.sp015548

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 404

Metadata

Authors
Cahalan, M. D., Chandy, K. G., DeCoursey, T. E., & Gupta, S.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1985-01
Volume
358
Issue
1
Pages
197-237
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2036704251
Cited by
404
References
3
FWCI
9.63
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A voltage‐gated potassium channel in human T lymphocytes. https://app.cochat.ai/papers/10.1113/jphysiol.1985.sp015548
The paper
Cahalan, M. D., Chandy, K. G., DeCoursey, T. E., & Gupta, S. (1985). A voltage‐gated potassium channel in human T lymphocytes. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1985.sp015548

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.