The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Spatial and temporal contrast sensitivities of neurones in lateral geniculate nucleus of macaque.
Open accessAbstract
The discharges of single neurones in the parvocellular and magnocellular laminae of the macaque's lateral geniculate nucleus (l.g.n.) were recorded with glass‐insulated tungsten micro‐electrodes. Linearity of spatial summation was examined using the test devised by Hochstein & Shapley (1976). 2 of 272 parvocellular units and 6 of 105 magnocellular units showed clearly non‐linear spatial summation. A quantitative index of non‐linearity did not suggest the existence of a distinct 'non‐linear' class of magnocellular unit. Spatial contrast sensitivity to moving gratings was measured by a tracking procedure in which contrast was adjusted to elicit a reliable modulation of discharge. With the exception of cells that were driven by blue‐sensitive cones, measurements of contrast sensitivity did not reveal distinct subgroups of parvocellular units. All had low sensitivity, and those with receptive fields in the fovea could resolve spatial frequencies of up to 40 cycles deg‐1. Magnocellular units had substantially higher sensitivity, but poorer spatial resolution. The higher sensitivities of magnocellular units led to their giving saturated responses to stimuli of high contrast. Responses of parvocellular units were rarely saturated by any stimulus. At any one eccentricity the receptive fields of parvocellular units had smaller centres than did those of magnocellular units. Receptive fields of magnocellular units driven by the ipsilateral eye had larger receptive fields than did those driven by the contralateral eye. Parvocellular units were most sensitive to stimuli modulated at temporal frequencies close to 10 Hz; magnocellular units to stimuli modulated at frequencies nearer 20 Hz. The loss of sensitivity as temporal frequency fell below optimum was more marked in magnocellular than parvocellular units. Changes in temporal frequency altered the shapes of the spatial contrast sensitivity curves of both parvocellular and magnocellular units. These changes could be explained by supposing that centre and surround have different temporal properties, and that the surround is relatively less sensitive to higher temporal frequencies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The contrast sensitivity of retinal ganglion cells of the cat
Enroth-Cugell, C., & Robson, J. G. (1966) · The Journal of Physiology · doi:10.1113/jphysiol.1966.sp008107 · Cited by 2,625
Chromatic mechanisms in lateral geniculate nucleus of macaque.
Derrington, A. M., Krauskopf, J., & Lennie, P. (1984) · The Journal of Physiology · doi:10.1113/jphysiol.1984.sp015499 · Cited by 1,608
Self-citationSpatial and chromatic interactions in the lateral geniculate body of the rhesus monkey.
Wiesel, T. N., & Hubel, D. H. (1966) · Journal of Neurophysiology · doi:10.1152/jn.1966.29.6.1115 · Cited by 1,275
Optical quality of the human eye
Campbell, F. W., & Gubisch, R. W. (1966) · The Journal of Physiology · doi:10.1113/jphysiol.1966.sp008056 · Cited by 810
Quantitative analysis of cat retinal ganglion cell response to visual stimuli
Rodieck, R. W. (1965) · Vision Research · doi:10.1016/0042-6989(65)90033-7 · Cited by 764
Retinal ganglion cells that project to the dorsal lateral geniculate nucleus in the macaque monkey
Perry, V. H., Oehler, R., & Cowey, A. (1984) · Neuroscience · doi:10.1016/0306-4522(84)90006-x · Cited by 717
Probability summation and regional variation in contrast sensitivity across the visual field
Robson, J. G., & Graham, N. (1981) · Vision Research · doi:10.1016/0042-6989(81)90169-3 · Cited by 616
X and Y cells in the lateral geniculate nucleus of macaque monkeys.
Kaplan, E., & Shapley, R. M. (1982) · The Journal of Physiology · doi:10.1113/jphysiol.1982.sp014333 · Cited by 601
Glass-coated platinum-plated tungsten microelectrodes
Merrill, E. G., & Ainsworth, A. (1972) · Medical & Biological Engineering · doi:10.1007/bf02476084 · Cited by 594
Dreher, B., Fukada, Y., & Rodieck, R. W. (1976) · The Journal of Physiology · doi:10.1113/jphysiol.1976.sp011429 · Cited by 548
Functional specificity of lateral geniculate nucleus laminae of the rhesus monkey
Schiller, P. H., & Malpeli, J. G. (1978) · Journal of Neurophysiology · doi:10.1152/jn.1978.41.3.788 · Cited by 545
The effect of contrast on the transfer properties of cat retinal ganglion cells.
Shapley, R. M., & Victor, J. D. (1978) · The Journal of Physiology · doi:10.1113/jphysiol.1978.sp012571 · Cited by 526
Quantitative analysis of retinal ganglion cell classifications.
Hochstein, S., & Shapley, R. M. (1976) · The Journal of Physiology · doi:10.1113/jphysiol.1976.sp011594 · Cited by 477
Retinal Ganglion Cell Classes in the Old World Monkey: Morphology and Central Projections
Leventhal, A. G., Rodieck, R. W., & Dreher, B. (1981) · Science · doi:10.1126/science.7268423 · Cited by 460
De Valois, R. L., Morgan, H., & Snodderly, D. M. (1974) · Vision Research · doi:10.1016/0042-6989(74)90118-7 · Cited by 442
Connolly, M., & Van Essen, D. (1984) · Journal of Comparative Neurology · doi:10.1002/cne.902260408 · Cited by 318
Watson, A. B., Barlow, H. B., & Robson, J. G. (1983) · Nature · doi:10.1038/302419a0 · Cited by 284
Spatio‐temporal interactions in cat retinal ganglion cells showing linear spatial summation.
Enroth‐Cugell, C., Robson, J. G., Schweitzer‐Tong, D. E., & Watson, A. B. (1983) · The Journal of Physiology · doi:10.1113/jphysiol.1983.sp014806 · Cited by 254
The responses of cells in macaque lateral geniculate nucleus to sinusoidal gratings.
Hicks, T. P., Lee, B. B., & Vidyasagar, T. R. (1983) · The Journal of Physiology · doi:10.1113/jphysiol.1983.sp014619 · Cited by 230
Derrington, A. M., & Lennie, P. (1982) · The Journal of Physiology · doi:10.1113/jphysiol.1982.sp014457 · Cited by 156
Self-citationStudies of the optic nerve of the rhesus monkey: Nerve fiber spectrum and physiological properties
Ogden, T. E., & Miller, R. F. (1966) · Vision Research · doi:10.1016/0042-6989(66)90001-0 · Cited by 150
Psychophysical evidence for sustained and transient channels in the monkey visual system
Harwerth, R. S., Boltz, R. L., & Smith, E. L. (1980) · Vision Research · doi:10.1016/0042-6989(80)90137-6 · Cited by 99
Concealed colour opponency in ganglion cells of the rhesus monkey retina.
de Monasterio, F. M., Gouras, P., & Tolhurst, D. J. (1975) · The Journal of Physiology · doi:10.1113/jphysiol.1975.sp011088 · Cited by 97
Cone systems interaction in single neurons of the lateral geniculate nucleus of the macaque
Padmos, P., & Norren, D. V. (1975) · Vision Research · doi:10.1016/0042-6989(75)90311-9 · Cited by 57
Protan‐like spectral sensitivity of foveal Y ganglion cells of the retina of macaque monkeys.
de Monasterio, F. M., & Schein, S. (1980) · The Journal of Physiology · doi:10.1113/jphysiol.1980.sp013131 · Cited by 50
Temporal modulation sensitivity of macaque monkeys
Merigan, W. H. (1980) · Vision Research · doi:10.1016/0042-6989(80)90077-2 · Cited by 27
Cited by
SlowFast Networks for Video Recognition
Feichtenhofer, C., Fan, H., Malik, J., & He, K. (2019) · 2019 IEEE/CVF International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2019.00630 · Cited by 4,007
Segregation of Form, Color, Movement, and Depth: Anatomy, Physiology, and Perception
Livingstone, M., & Hubel, D. (1988) · Science · doi:10.1126/science.3283936 · Cited by 3,355
Normalization of cell responses in cat striate cortex
Heeger, D. J. (1992) · Visual Neuroscience · doi:10.1017/s0952523800009640 · Cited by 1,835
Chromatic mechanisms in lateral geniculate nucleus of macaque.
Derrington, A. M., Krauskopf, J., & Lennie, P. (1984) · The Journal of Physiology · doi:10.1113/jphysiol.1984.sp015499 · Cited by 1,608
Self-citationHow parallel are the primate visual pathways?
Merigan, W. H., & Maunsell, J. H. R. (1993) · Annual Review of Neuroscience · doi:10.1146/annurev.ne.16.030193.002101 · Cited by 1,597
Metadata
- Authors
- Derrington, A. M., & Lennie, P.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1984-12
- Volume
- 357
- Issue
- 1
- Pages
- 219-240
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W1996822428
- Cited by
- 1,058
- References
- 26
- FWCI
- 6.97
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.