CoChat

Steady‐state fluid filtration at different capillary pressures in perfused frog mesenteric capillaries.

Open access
Michel, C C, Phillips, M E · 1987 · The Journal of Physiology
Cited by 134

The DOI matches its Crossref record.

Abstract

1. The theory of steady‐state filtration through capillary walls (Michel, 1984) has been developed and investigated in experiments on single capillaries of the frog mesentery perfused with Ringer solutions containing bovine serum albumin (BSA) and Ficoll 70. 2. In each experiment, the micro‐occlusion technique of Michel, Mason, Curry, Tooke & Hunter (1974) has been used to investigate the relation between fluid movements per unit area of capillary wall (Jv/A) and capillary pressure (Pc) under two sets of conditions in the same vessel. First, the relation has been determined following brief perfusions, where the difference in oncotic pressure across the capillary wall approximated to the perfusate oncotic pressure at all values of Pc. These results are referred to as the transient data. Secondly, the relation was investigated by estimating Jv/A at values of Pc which had been maintained constant during at least 2 min of perfusion prior to the measurement. Under these conditions the concentration of macromolecules in the pericapillary fluid was determined by the steady‐state composition of the filtrate passing through the capillary wall, and these results are referred to as steady‐state data. 3. In all fifteen capillaries investigated, the relationship between Jv/A and Pc was linear for the transient data and conspicuously non‐linear in the steady state. When Pc exceeded the oncotic pressure of the perfusate, steady‐state values for Jv/A lay slightly above but parallel to the transient values for the same vessel. At values of Pc less than the perfusate oncotic pressure, the transient data showed reabsorption of fluid from the tissues, but in the steady state either fluid movements were so small as to be undetected or slight filtration was observed. The steady‐state data followed the pattern predicted by theory. 4. The transient data were used to estimate the reflection coefficient of the capillary wall (sigma) to the macromolecular solute. In seven vessels, the mean sigma to BSA was 0.76 (S.E. of mean +/‐ 0.04) and in eight different vessels mean sigma to Ficoll 70 in the presence of BSA (10 mg ml‐1) was 0.98 (S.E. of mean +/‐ 0.05). The steady‐state data were consistent with the prediction that the oncotic pressure opposing high filtration rates approximates to sigma 2 pi c in the steady state, where pi c is the perfusate oncotic pressure.(ABSTRACT TRUNCATED AT 400 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1987.sp016622

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 134

Metadata

Authors
Michel, C. C., & Phillips, M. E.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1987-07
Volume
388
Issue
1
Pages
421-435
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2137847399
Cited by
134
References
0
FWCI
2.31
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Steady‐state fluid filtration at different capillary pressures in perfused frog mesenteric capillaries. https://app.cochat.ai/papers/10.1113/jphysiol.1987.sp016622
The paper
Michel, C. C., & Phillips, M. E. (1987). Steady‐state fluid filtration at different capillary pressures in perfused frog mesenteric capillaries. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1987.sp016622

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.