The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Microvascular Permeability
Abstract
This review addresses classical questions concerning microvascular permeabiltiy in the light of recent experimental work on intact microvascular beds, single perfused microvessels, and endothelial cell cultures. Analyses, based on ultrastructural data from serial sections of the clefts between the endothelial cells of microvessels with continuous walls, conform to the hypothesis that different permeabilities to water and small hydrophilic solutes in microvessels of different tissues can be accounted for by tortuous three-dimensional pathways that pass through breaks in the junctional strands. A fiber matrix ultrafilter at the luminal entrance to the clefts is essential if microvascular walls are to retain their low permeability to macromolecules. Quantitative estimates of exchange through the channels in the endothelial cell membranes suggest that these contribute little to the permeability of most but not all microvessels. The arguments against the convective transport of macromolecules through porous pathways and for the passage of macromolecules by transcytosis via mechanisms linked to the integrity of endothelial vesicles are evaluated. Finally, intracellular signaling mechanisms implicated in transient increases in venular microvessel permeability such as occur in acute inflammation are reviewed in relation to studies of the molecular mechanisms involved in signal transduction in cultured endothelial cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Functional rafts in cell membranes
Simons, K., & Ikonen, E. (1997) · Nature · doi:10.1038/42408 · Cited by 9,757
Flow-mediated endothelial mechanotransduction
Davies, P. F. (1995) · Physiological Reviews · doi:10.1152/physrev.1995.75.3.519 · Cited by 2,802
Occludin: a novel integral membrane protein localizing at tight junctions.
Furuse, M., Hirase, T., Itoh, M., Nagafuchi, A., Yonemura, S., Tsukita, S., & Tsukita, S. (1993) · The Journal of cell biology · doi:10.1083/jcb.123.6.1777 · Cited by 2,580
Transferrin receptor on endothelium of brain capillaries
Jefferies, W. A., Brandon, M. R., Hunt, S. V., Williams, A. F., Gatter, K. C., & Mason, D. Y. (1984) · Nature · doi:10.1038/312162a0 · Cited by 1,061
Suttorp, N., Hippenstiel, S., Fuhrmann, M., Krull, M., & Podzuweit, T. (1996) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1996.270.3.c778 · Cited by 133
Cited by
Microvascular fluid exchange and the revised Starling principle
Levick, J. R., & Michel, C. C. (2010) · Cardiovascular Research · doi:10.1093/cvr/cvq062 · Cited by 1,183
Self-citationVascular Endothelial Cell Biology: An Update
Krüger-Genge, A., Blocki, A., Franke, R.-P., & Jung, F. (2019) · International Journal of Molecular Sciences · doi:10.3390/ijms20184411 · Cited by 1,163
Three-dimensional microfluidic model for tumor cell intravasation and endothelial barrier function
Zervantonakis, I. K., Hughes-Alford, S. K., Charest, J. L., Condeelis, J. S., Gertler, F. B., & Kamm, R. D. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1210182109 · Cited by 872
Klaassen, I., Van Noorden, C. J. F., & Schlingemann, R. O. (2013) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2013.02.001 · Cited by 722
Wiig, H., & Swartz, M. A. (2012) · Physiological Reviews · doi:10.1152/physrev.00037.2011 · Cited by 722
Metadata
- Authors
- Michel, C. C., & Curry, F. E.
- Venue
- Physiological Reviews
- Publisher
- American Physiological Society
- Published
- 1999-07-01
- Volume
- 79
- Issue
- 3
- Pages
- 703-761
- ISSN
- 0031-9333 (ISSN-L)
- 1522-1210
- OpenAlex
- W4211094368
- Cited by
- 811
- References
- 5
- FWCI
- 1.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microvascular Permeability. https://app.cochat.ai/papers/10.1152/physrev.1999.79.3.703
- The paper
- Michel, C. C., & Curry, F. E. (1999). Microvascular Permeability. Physiological Reviews. https://doi.org/10.1152/physrev.1999.79.3.703
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.