CoChat

Desensitization of the acetylcholine receptor of frog end‐plates measured in a Vaseline‐gap voltage clamp.

Open access
Cachelin, A B, Colquhoun, D · 1989 · The Journal of Physiology
Cited by 96

The DOI matches its Crossref record.

Abstract

1. Desensitization of the nicotinic acetylcholine receptor of the frog end‐plate was investigated in dissociated frog muscle fibres using the Vaseline‐gap clamp method so that a wide range of well‐defined agonist concentrations could be used without having to use alpha‐bungarotoxin to reduce currents, and so that the intracellular medium could be controlled. 2. Acetylcholine (ACh) concentrations between 1 and 1000 microM were used, after inactivation of acetylcholinesterase. The intracellular calcium concentration was usually kept near zero by using 80 mM‐K2EGTA as the intracellular solution. 3. When using the low intracellular calcium solution, desensitization proceeded as a biphasic process with estimates of fast and slow time constants of about 8 and 80 s at 4 degrees C and 20 microM‐ACh (the rates increased with concentration). In contrast, only one (fast) component of desensitization was detected when the intracellular calcium concentration was allowed to increase during ACh application. 4. Despite rapid application of ACh the time to peak response was 0.2 s (with 400 microM‐ACh) to 2 s (with 1 microM‐ACh); this slow rise was shown to result from diffusion delays. Nevertheless the peak current with 200 microM‐ACh corresponded to opening of most of the channels present, so there is probably not much desensitization in the millisecond time range. 5. Both fast and slow time constants for onset of desensitization showed only slight dependence on membrane potential when [Ca2+]i was buffered with 80 mM‐K2EGTA. 6. Increasing the intracellular cyclic AMP concentration directly, or indirectly with forskolin and IBMX, had no effect on the time course of desensitization. 7. Intracellular application of submicromolar concentrations of phorbol‐12,13‐dibutyrate (PDBu) and phorbol‐12‐myristate‐13‐acetate (PMA) yielded a small but reproducible reduction of the peak response to ACh. The time course of desensitization was, however, not modified by these substances. 8. The implications of these observations for the mechanism of desensitization, and their relationship to single‐channel observations, are discussed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1989.sp017717

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Cachelin, A. B., & Colquhoun, D.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1989-08
Volume
415
Issue
1
Pages
159-188
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W1995141792
Cited by
96
References
0
FWCI
3.84
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.