CoChat

Co‐ordination of pumping in isolated bovine lymphatic vessels.

Open access
McHale, N G, Meharg, M K · 1992 · The Journal of Physiology
Cited by 103

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

1. Segments of bovine mesenteric lymphatic of varying diameter taken from different parts of the lymphatic tree were cut to 20 mm in length and set up so that measurements could be made of spontaneous isometric contractions. 2. There was considerable variability in frequency of spontaneous contractions but this was independent of resting tension. There was no significant correlation between lymphatic diameter and inherent frequency of contraction. 3. Isolated segments of bovine mesenteric lymphatic 70‐80 mm in length were cannulated and set up in a three‐compartment organ bath which allowed independent temperature control in each compartment. Pressure was recorded at inflow and outflow ends and experiments were video recorded. 4. Contractile activity was normally initiated at the end of the lymphatic maintained at the higher temperature and the contractile wave was propagated along the length of the vessel. 5. Propagation could occur either in the direction of valve orientation (orthograde) or retrogradely. The volume of fluid pumped was not significantly affected by the direction of propagation. 6. Perfusion of the central compartment with Krebs solution at 0‐2 degrees C disrupted normal propagation and allowed the two parts of the lymphatic to contract at different frequencies although the two parts maintained an approximately 2:1 ratio. 7. Perfusion of the central compartment with 10 mM‐heptanol also disrupted normal propagation but the rates on either side of the partition bore no harmonic relationship to one another. 8. These results suggest that relatively short segments of lymph duct have the ability to contract spontaneously and that their inherent frequencies are not determined by their position in the lymphatic tree. The results are consistent with the existence of electrical coupling along the lymphatic's length and they suggest that over distances of at least 80 mm independent pacemakers are capable of mutual entrainment at a frequency representing a compromise between the fastest and slowest components.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1992.sp019139

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 103

Metadata

Authors
McHale, N. G., & Meharg, M. K.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1992-05
Volume
450
Issue
1
Pages
503-512
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2057245677
Cited by
103
References
1
FWCI
0.31
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Co‐ordination of pumping in isolated bovine lymphatic vessels. https://app.cochat.ai/papers/10.1113/jphysiol.1992.sp019139
The paper
McHale, N. G., & Meharg, M. K. (1992). Co‐ordination of pumping in isolated bovine lymphatic vessels. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1992.sp019139

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.