The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Optical monitoring of transmitter release and synaptic vesicle recycling at the frog neuromuscular junction.
Open accessAbstract
1. Frog cutaneous pectoris motor nerve terminals were loaded with the fluorescent dye FM1‐43, which produced a series of discrete spots along the length of terminals, each spot evidently marking a cluster of synaptic vesicles. Terminals were imaged for 2‐10 min as they destained during repetitive nerve stimulation. Endplate potentials (EPPs) were recorded simultaneously from the muscle fibres innervated by these terminals; their summed amplitudes provided a measure of cumulative transmitter release. 2. Individual fluorescent spots in any one terminal varied in initial brightness but destained at similar fractional rates. 3. The rates of cumulative transmitter release and destaining increased with stimulus frequency in the range 2‐30 Hz. At 40 Hz, however, both transmitter release and destaining were slower than at 30 Hz. 4. In twenty‐six experiments, rates of dye loss and transmitter release were compared quantitatively. When the time course of summed EPPs was scaled to fit the time course of dye loss during the first 30‐60 s of destaining, the two curves usually diverged at later times, the dye loss curve falling below the summed EPP curve. Thus, assuming that dye loss and transmitter release are proportional at early times, at later times the rate of dye loss decreases relative to the rate of transmitter release. 5. At stimulus frequencies from 2 to 30 Hz, the results could be fitted by a simple model in which vesicles lose their dye during exocytosis and, after a fixed recycle ‘dead time’, they re‐enter the vesicle pool, mixing randomly with other vesicles. 6. Unlike stimulation at lower frequencies, at 40 Hz dye loss and summed EPP amplitude curves did not significantly diverge. Stimulation periods lasted up to about 2 min. Interpreted according to the model of vesicle recycling, this suggests that vesicle recycling is inhibited at 40 Hz. 7. The model led to predictions about the relative number, N, of vesicles (labelled and unlabelled) in the terminal at any time during stimulation. The calculated value of N decreased at times less than the recycle ‘dead time’, and then increased, reflecting the appearance of recycled vesicles in the vesicle pool. 8. From estimates of N and recorded EPP amplitudes, the fraction of vesicles released per shock, F, could be calculated during the entire stimulation period. At low stimulus frequencies (2‐5 Hz), after an initial rapid fall, F decreased slowly and monotonically by about 50% in 6 min. At higher stimulus frequencies, a different process was observed.(ABSTRACT TRUNCATED AT 400 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The organization of cytoplasm at the presynaptic active zone of a central nervous system synapse
Landis, D. M. D., Hall, A. K., Weinstein, L. A., & Reese, T. S. (1988) · Neuron · doi:10.1016/0896-6273(88)90140-7 · Cited by 333
Cited by
Neurotrophin regulation of neural circuit development and function
Park, H., & Poo, M.-M. (2013) · Nature Reviews Neuroscience · doi:10.1038/nrn3379 · Cited by 2,060
Neher, E. (1998) · Neuron · doi:10.1016/s0896-6273(00)80983-6 · Cited by 1,010
The kinetics of synaptic vesicle recycling measured at single presynaptic boutons
Ryan, T. A., Reuter, H., Wendland, B., Schweizer, F. E., Tsien, R. W., & Smith, S. J. (1993) · Neuron · doi:10.1016/0896-6273(93)90081-2 · Cited by 517
Transport, capture and exocytosis of single synaptic vesicles at active zones
Zenisek, D., Steyer, J. A., & Almers, W. (2000) · Nature · doi:10.1038/35022500 · Cited by 463
Imaging exocytosis and endocytosis
Betz, W. J., Mao, F., & Smith, C. B. (1996) · Current Opinion in Neurobiology · doi:10.1016/s0959-4388(96)80121-8 · Cited by 445
Self-citation
Metadata
- Authors
- Betz, W. J., & Bewick, G. S.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1993-01
- Volume
- 460
- Issue
- 1
- Pages
- 287-309
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W1983982481
- Cited by
- 213
- References
- 1
- FWCI
- 5.16
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optical monitoring of transmitter release and synaptic vesicle recycling at the frog neuromuscular junction. https://app.cochat.ai/papers/10.1113/jphysiol.1993.sp019472
- The paper
- Betz, W. J., & Bewick, G. S. (1993). Optical monitoring of transmitter release and synaptic vesicle recycling at the frog neuromuscular junction. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1993.sp019472
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.