Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 216

The DOI matches its Crossref record.

Measurement of cytoplasmic calcium concentration in the rods of wild‐type and transducin knock‐out mice

Open access
Woodruff, Michael L., Sampath, A. P., Matthews, Hugh R., Krasnoperova, N. V., Lem, J., Fain, Gordon L.·2002·The Journal of Physiology

Abstract

A 10 μm spot of argon laser light was focused onto the outer segments of intact mouse rods loaded with fluo‐3, fluo‐4 or fluo‐5F, to estimate dark, resting free Ca 2+ concentration ([Ca 2+]i) and changes in [Ca 2+]i upon illumination. Dye concentration was adjusted to preserve the normal physiology of the rod, and the laser intensity was selected to minimise bleaching of the fluorescent dye. Wild‐type mouse rods illuminated continuously with laser light showed a progressive decrease in fluorescence well fitted by two exponentials with mean time constants of 154 and 540 ms. Rods from transducin α‐subunit knock‐out (Trα–/–) animals showed no light‐dependent decline in fluorescence but exhibited an initial rapid component of fluorescence increase which could be fitted with a single exponential (τ∼1–4 ms). This fluorescence increase was triggered by rhodopsin bleaching, since its amplitude was reduced by pre‐exposure to bright bleaching light and its time constant decreased with increasing laser intensity. The rapid component was however unaffected by incorporation of the calcium chelator BAPTA and seemed therefore not to reflect an actual increase in [Ca 2+]i. A similar rapid increase in fluorescence was also seen in the rods of wild‐type mice just preceding the fall in fluorescence produced by the light‐dependent decrease in [Ca 2+]i. Dissociation constants were measured in vitro for fluo‐3, fluo‐4 and fluo‐5F with and without 1 m m Mg 2+ from 20 to 37 °C. All three dyes showed a strong temperature dependence, with the dissociation constant changing by a factor of 3–4 over this range. Values at 37 °C were used to estimate absolute levels of rod [Ca 2+]i. All three dyes gave similar values for [Ca 2+]i in wild‐type rods of 250 ± 20 n m in darkness and 23 ± 2 n m after exposure to saturating light. There was no significant difference in dark [Ca 2+]i between wild‐type and Trα–/– animals.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.2001.013987

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 216

Metadata

Authors
Woodruff, M. L., Sampath, A. P., Matthews, H. R., Krasnoperova, N. V., Lem, J., & Fain, G. L.
Venue
The Journal of Physiology
Publisher
Wiley
Published
2002-08
Volume
542
Issue
3
Pages
843-854
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2045519476
Cited by
216
References
0
FWCI
2.32
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measurement of cytoplasmic calcium concentration in the rods of wild‐type and transducin knock‐out mice. https://app.cochat.ai/papers/10.1113/jphysiol.2001.013987
The paper
Woodruff, M. L., Sampath, A. P., Matthews, H. R., Krasnoperova, N. V., Lem, J., & Fain, G. L. (2002). Measurement of cytoplasmic calcium concentration in the rods of wild‐type and transducin knock‐out mice. The Journal of Physiology. https://doi.org/10.1113/jphysiol.2001.013987

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.