Regional distribution of hyperpolarization‐activated current (If) and hyperpolarization‐activated cyclic nucleotide‐gated channel mRNA expression in ventricular cells from control and hypertrophied rat hearts
Open accessThe DOI matches its Crossref record.
Abstract
Hyperpolarization‐activated inward current (If) and changes in the messenger RNA (mRNA) expression levels of hyperpolarization‐activated cyclic nucleotide‐gated channel (HCN)2 and HCN4 encoding If channels of the rat heart were studied in control and hypertrophied myocytes isolated from three ventricular regions: the septum (S), the left ventricular free wall (LV) and the right ventricular free wall (RV). Electrophysiological experiments were conducted by ruptured and perforated‐patch clamp techniques and quantification of mRNA levels was carried out by quantitative reverse transcriptase polymerase chain reaction. The occurrence, density and maximal specific conductance of If were found to be significantly higher in hypertrophied ventricular myocytes isolated from S and LV than in those isolated from RV or sham‐operated rats. Half‐maximal activation potential, the slope of the activation curve and the threshold for activation were similar in ventricular myocytes from sham and aortic stenosed rats in the three regions studied. Isoproterenol 1 µmol l−1 increased current size by shifting current activation to more positive potentials in both sham and hypertrophied myocytes. When we studied the mRNA levels of If channel isoforms present in the ventricle, we found a significant increase of HCN2 and HCN4 mRNA levels in hypertrophied myocytes from S and LV but not in RV. We conclude that the occurrence, density and conductance of If is higher in hypertrophied than in control ventricular myocytes, S being the region where all these changes were most evident. These findings are associated with a higher expression of HCN2 and HCN4 mRNA levels in the two regions that developed hypertrophy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hyperpolarization-Activated Cation Channels: From Genes to Function
Biel, M., Wahl-Schott, C., Michalakis, S., & Zong, X. (2009) · Physiological Reviews · doi:10.1152/physrev.00029.2008 · Cited by 1,003
The Role of the Funny Current in Pacemaker Activity
DiFrancesco, D. (2010) · Circulation Research · doi:10.1161/circresaha.109.208041 · Cited by 587
HCN channels: Structure, cellular regulation and physiological function
Wahl-Schott, C., & Biel, M. (2009) · Cellular and Molecular Life Sciences · doi:10.1007/s00018-008-8525-0 · Cited by 433
What keeps us ticking: a funny current, a calcium clock, or both?
Lakatta, E. G., & DiFrancesco, D. (2009) · Journal of Molecular and Cellular Cardiology · doi:10.1016/j.yjmcc.2009.03.022 · Cited by 291
Xiao, J., Yang, B., Lin, H., Lu, Y., Luo, X., & Wang, Z. (2007) · Journal of Cellular Physiology · doi:10.1002/jcp.21062 · Cited by 193
“In addition to the conduction system, If is also constitutively present in atrial and ventricular non-pacemaker myocytes (Cerbai et al., 1997; Hoppe et al., 1998; Fernandez-Velasco et al., 2003).”
BackgroundRetractedLuo, X., Lin, H., Pan, Z., Xiao, J., Zhang, Y., Lu, Y., Yang, B., & Wang, Z. (2008) · Journal of Biological Chemistry · doi:10.1074/jbc.m801035200 · Cited by 177
RetractedMolecular basis of funny current (If) in normal and failing human heart
Stillitano, F., Lonardo, G., Zicha, S., Varro, A., Cerbai, E., Mugelli, A., & Nattel, S. (2008) · Journal of Molecular and Cellular Cardiology · doi:10.1016/j.yjmcc.2008.04.013 · Cited by 173
“A higher If expression has been detected in the left compared to the right ventricle in rat myocytes [36,37], but to our knowledge, no information exists on transmural variation of If within the left ventricle.”
BackgroundBaruscotti, M., Barbuti, A., & Bucchi, A. (2010) · Journal of Molecular and Cellular Cardiology · doi:10.1016/j.yjmcc.2009.06.019 · Cited by 149
Sartiani, L., Mannaioni, G., Masi, A., Novella Romanelli, M., & Cerbai, E. (2017) · Pharmacological Reviews · doi:10.1124/pr.117.014035 · Cited by 143
“Interestingly, the expression of the HCN channels appears more pronounced in ventricular regions with the greatest overload, suggesting the possibility of mechano‐sensitive mechanism of channel expression (Fernández-Velasco et al., 2003).”
BackgroundInfluentialHCN Channels Modulators: The Need for Selectivity
Novella Romanelli, M., Sartiani, L., Masi, A., Mannaioni, G., Manetti, D., Mugelli, A., & Cerbai, E. (2016) · Current Topics in Medicinal Chemistry · doi:10.2174/1568026616999160315130832 · Cited by 73
Metadata
- Authors
- Fernández‐Velasco, M., Goren, N., Benito, G., Blanco‐Rivero, J., Boscá, L., & Delgado, C.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 2003-12
- Volume
- 553
- Issue
- 2
- Pages
- 395-405
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2029062125
- Cited by
- 105
- References
- 0
- FWCI
- 3.56
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.